1591Series Installs

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail: [email protected] 1591U ...

4 downloads 77 Views 106KB Size
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail: [email protected]

1591U EMLOCK® INSTALLATION INSTRUCTIONS 1.

Prepare door jamb for EMLock per template drawing.

2.

Locate reinforcement plate and mounting tabs as shown.

3.

Center Armature Plate to the centerline of the lock. The cutout for the armature must be 1-1/2” wide and 6-1/2” long.

4.

Install an armature reinforcement plate or the Amp mounting plate so that there is a 5/8” pocket when measured from the leading edge of the door. The AMP mounting plate is used to reinforce the mortise cutout in a wood door. It is secured to the door with four (4) #10 wood screws and then the EMLock armature is secured to the mounting plate with a 5/16”-18 x 3/4” bolt.

NOTE: The AMP mounting plate is an option available from SDC. 5.

Attach the EMLock wire leads to the power source and then install the EMLock and the armature with screws provided.

SYSTEM WIRING ACCESS, EGRESS AND REMOTE CONTROLS

+ TO 24VDC (+/-10%) FUSED, REGULATED & FILTERED POWER SOURCE

(+) RED/BLK

RED

ELECTRONICS -

(-) WHT/BLK

RED

(+) RED/BLK

RED

RED BLK ORG WHT

24V CONFIGURATION

RED ORG BLK WHT

12V CONFIGURATION

ACCESS, EGRESS AND REMOTE CONTROLS

+ TO 12VDC (+/-10%) FUSED, REGULATED & FILTERED POWER SOURCE

ELECTRONICS -

RED

(-) WHT/BLK 1591U – DPS OPTION N/C ORG

COM

N/O

YEL GRY

(POLARITY SHOWN WITH THE DOOR OPEN)

IMPORTANT WIRING INFORMATION:

Use the system wiring diagram to configure the EMLock for 12 VDC or 24 VDC operation. Although using a DC power supply is recommended, a transformer with a bridge rectifier may also be used as a DC power source. If you are using a transformer and rectifier, a transformer with the correct output voltage must be used. Access controls must not be wired to the AC side of the bridge rectifier or power supply. Access controls must always be wired to break the DC side of the power source. P:\INSTALLATION INST\Electromagnetic Locks\INST-1591U.vsd

REV C

01-17

Page 1

1.000 1.470

FRAME OR SLIDING DOOR

OUTLINE DIMESIONS

WIRE EXIT EITHER END DOOR CUTOUT

FRAME

DOOR

1.48 WIDE

.125

1.500 CL

.180

.500

1.000

.180

1.500

2.750

2.250

1.000 6.310

11.125

CL

6.500 1.000

5/16-18 TAP THRU

2.250

2.750

.250 DIA 2 PLACES .312

DRILL FOR #10-1 SCREW 4 PLACES

.750

1591 EMLOCK

10.030

9.250

10.000

8.000

REINFORCING

REINFORCING OR AMP MOUNTING PLATE

ARMATURE

1.485 WIDE

.680 .250

2 RUBBER WASHERS

1.025

1.025 .125

5/16 x 8 SCREW

OUTLINE DIMENSIONS

ARMATURE

REINFORCEMENT

1.750

SPACER

FRAME CUTOUT

1 STEEL WASHER

DOOR AND FRAME PREPARATION 1591U EMLOCK®

P:\INSTALLATION INST\Electromagnetic Locks\INST-1591U.vsd

REV B

01-17

Page 2

9.250

11.125