PRODUCT CATALOG 2011
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com responsible
energy
A DIVISION OF
NSi INDUSTRIES, LLC
NSi Industries LLC
About Us Since 1975, NSi’s strength is in the unique products that we bring to the market, combined with our exceptional ability to provide quality TORK® brand products manufactured in the company’s Mount Vernon facility. TORK® is NSi Industries largest brand, covering the categories of Electromechanical and Digital Time Switches, Signaling and Alert Devices, Pool and Spa Controls, Residential Timers, Photocontrols and Occupancy Sensors. For over 85 years, TORK brand recognition and reputation for quality and design make it the most specified brand in the industry. The TORK brand has a rich history beginning in the 1920s when the company introduced the first electromechanical time switch to the marketplace. Currently, TORK’s time switches maintain energy efficiency through lighting control in such high profile places as the Empire State Building, Washington DC Parks and Recreation, The Triborough Bridge, The Met Life Building and many more institutions across the country. As the most specified brand of time switches in the industry, TORK enjoys the hearty respect of engineers and project planners across all channels of distribution. In the past several years, we’ve introduced a number of TORK time switches, in-wall and plug-in timers to meet increasingly specific needs in the marketplace. We’ve also added a line of installer-friendly pool and spa panels and time switches, and are proud to offer essential pool safety products that meet and exceed federal requirements for safe pools. We look forward to designing and engineering more of our Responsible Energy products, helping save money and the environment through responsible and minimal use of energy.
TABLE OF CONTENTS
TABLE OF CONTENTS
ENERGY CODE REFERENCE GUIDE . . . . . . . . . . . . . 7 PHOTOCONTROLS
QUICK LOOK FEATURES & COMMON FEATURES . . . 2100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2110 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2001 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2020 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5000M SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 2005A, 2007A, 2008A SERIES . . . . . . . . . . . . . . . 5200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5400 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5737 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . PHOTOCONTROL ACCESSORIES . . . . . . . . . . . . . . .
11 13 14 15 16 17 18 19 20 21 22 23 24
ELECTROMECHANICAL
QUICK LOOK FEATURES & COMMON FEATURES . . . 27 TU40 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 1100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 7000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 7000Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8000 SERIES, DUTY CYCLE . . . . . . . . . . . . . . . . . . 37 8000 SERIES, REPEATING VARIABLE CYCLE . . . . . . 39 WH2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 1800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 W SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 T900 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 TZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 ELECTROMECHANICAL ENCLOSURES & DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . 153 DIGITAL
QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 53 DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 E SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 E-PB SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 EW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 EWZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 DG100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 DZS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 DTS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 DW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 DZM SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 ELC SERIES, 1 & 2 ZONE . . . . . . . . . . . . . . . . . . . 73 ELC SERIES, 4, 8 &12 ZONE . . . . . . . . . . . . . . . . . 75 LC200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 DGU SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 DGLC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 LD SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 DGS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EJWT & E500T SERIES . . . . . . . . . . . . . . . . . . . . . 87 DIN SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 5401 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 HPS STARTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 TRP SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 DIGITAL ENCLOSURES & DIMENSIONS . . . . . . . . . 153 IN-WALL TIMERS
QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 97 SS720A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 98 SS700Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99 SS721Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99 701A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 711A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 SSA SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 SS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 C SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 OCCUPANCY SENSORS
SENSOR TECHNOLOGY & PLACEMENT GUIDE . . . . 109 OSWS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 110 OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 OSC20UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 OSC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 ELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 TRP-U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 PLUG-IN TIMERS
400A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 400D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 600A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 600D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . TORK ALERT
119 120 121 122 123
MECHANICAL STROBE HORNS . . . . . . . . . . . . . . . MECHANICAL HORNS . . . . . . . . . . . . . . . . . . . . . MULTI-TONE ELECTRONIC HORNS . . . . . . . . . . . . HEAVY DUTY BELLS . . . . . . . . . . . . . . . . . . . . . . BELLS & BUZZERS . . . . . . . . . . . . . . . . . . . . . . . CHIMES & CHIME KITS . . . . . . . . . . . . . . . . . . . . WEATHERPROOF MOTOR DRIVEN SIREN . . . . . . . MANUAL FIRE ALARM . . . . . . . . . . . . . . . . . . . . TELEPHONE STROBE . . . . . . . . . . . . . . . . . . . . . . TELEPHONE HORN . . . . . . . . . . . . . . . . . . . . . . . TELEPHONE RELAY . . . . . . . . . . . . . . . . . . . . . . . WALL CLOCKS . . . . . . . . . . . . . . . . . . . . . . . . . . ELECTRIC DOOR OPENERS . . . . . . . . . . . . . . . . . PUSH-BUTTONS . . . . . . . . . . . . . . . . . . . . . . . . .
127 127 128 128 129 129 130 130 131 131 132 132 133 134
WARNING LIGHTS, INDUSTRIAL . . . . . . . . . . . . . 135 WARNING LIGHTS, VEHICULAR . . . . . . . . . . . . . . 136 POWER SUPPLY UNITS . . . . . . . . . . . . . . . . . . . . 137 TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . 137 ACCESSORIES/REPLACEMENT PARTS/DIMENSIONS 138 POOL & SPA
PP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . . 141 PFP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . 143 1100 SERIES TIMERS . . . . . . . . . . . . . . . . . . . . . 144 DW200B TIMER . . . . . . . . . . . . . . . . . . . . . . . . . 145 P1100 SERIES, 24 HOUR ELECTROMECHANICAL MECHANISMS . . . . . . . . . . 147 P1100 SERIES, 7 DAY DIGITAL MECHANISMS . . . 148 JUNCTION BOXES . . . . . . . . . . . . . . . . . . . . . . . 148 STINGL SR-500 & SR-500PS, SVRS . . . . . . . . . . 149 LAYERS OF PROTECTION . . . . . . . . . . . . . . . . . . . 150 ANTI-ENTRAPMENT DRAIN COVERS . . . . . . . . . . . 151 MAGNALATCH SELF-LATCHING GATE CLOSURES . . 152 TRUCLOSE SELF-CLOSING GATE HINGES . . . . . . . .152 POOL&SPA SAFETY ACCESSORIES . . . . . . . . . . . . 152 ENCLOSURE DIMENSIONS . . . . . . . . . . . . . . . . . . 153 ALPHANUMERIC INDEX . . . . . . . . . . . . . . . . . . . 155
LA N AR CH ITE CT U
energy saving solutions
Each of these marked products have features that decrease energy consumption and/or damage to the environment by one or more of the following: • Timed control, Photocontrol and/or Astronomic control of on responsible energy and off functions of lighting, fans, pumps and appliances • Timed control of systems or multiple zones of lighting • Photo or occupancy sensing control of lighting • Supercapacitor backup, no batteries to replace or dispose. • Helps meet CA Title 24, ASHRAE , IECC and other standards for responsible building products
Small Space, Meeting Rooms, Restrooms, Storage Spaces: Occupancy Sensors, Interval Timers The first zone includes small spaces such as offices, restrooms and storage areas places where people may not occupy the space continuously. Individual wall switch replacement provides low cost installation, with occupancy sensors and interval timers as the best solution. In the event that wall switches provide proper coverage for the occupancy sensor, ceiling mounted options are available.
FIC ES
energy
< Use the Quick Reference Energy Code Guide for approved products.
responsible
energy
RE CE P
TIO
N
responsible
ZONE 1: SMALL SPACE
Responsible Energy
OF
< Responsible Energy is the mark of TORK’s commitment to developing and manufacturing energy saving, environmentally friendly products.
FIC ES
solutions
The first way to save energy begins with eliminating lighting when it isn't needed. As with exterior lighting, an efficient design matches controls to the typical use of the area.
OF
energy saving
INTERIOR LIGHTING ZONES
RA L&
ENERGY CODE REFERENCE GUIDE
ZONE 2: LARGE SPACE Small Space, Meeting Rooms, Restrooms, Storage Spaces: Time of Day with Override, Occupancy Sensors
CALIFORNIA Title 24
LO
T
The first zone includes small spaces such as offices, restrooms and storage areas places where people may not occupy the space continuously. Individual wall switch replacement provides low cost installation, with occupancy sensors and interval timers as the best solution. In the event that wall switches provide proper coverage for the occupancy sensor, ceiling mounted options are available.
ZONE 3: HARVESTING LIGHT
CE
ON
T
RO
EXTERIOR LIGHTING ZONES
EN
When ambient light levels drop at dusk, lighting is needed to provide safety and security. BUT: Does all lighting need to be on all night long? The proper selection of lighting controls is essential to ensuring that energy is only used when needed. An efficient lighting control design creates zones of light levels that can be varied by time at night.
Large of Small Spaces with Natural Light: Light Sensors, Light Sensors with Occupancy, Astronomic Timers. A third zone that uses daylighting control can be added to wither of the first two zones. light sensors can shut off a portion of the lighting when windows or skylights contribute sufficient natural light to the area. This "harvesting" of light is an excellent, green way to conserve energy. (NOTE: Energy codes vary on the stated maximum time, but shorter times can give more energy savings).
E
FIC FIC
The first zone gives a minimum light level where security is the primary need. Determine what lighting is necessary, such as building-mounted wallpacks and a portion of the parking lot lighting. These should be on from dusk to dawn, and are best controlled by a photosensor device.
OF
ST
RE
Security Lighting (all night): Photocontrols, Photosensor controls
OF
WA R
EH
OU
SE
ZONE 1: MINIMUM LIGHT LEVEL / DUSK TO DAWN
E
RO
O
M
OF
RE
FIC
E
ST
RO
O
M
CO
NF
ER
FR
B RO REA OM K
OM
PA R
KIN
G
ASHRAE 90.1
ZONE 2: HIGHER LIGHT LEVEL / DUSK TO TIME OFF
FRONT PARKING LOT
Safety & Architectural Lighting (not necessary all night): Photosensor/Timebased controls, Astronomic controls The second zone provides a higher light level for safety, when people are normally present. Maximum levels for the parking lot and all walkway lighting are needed. These lights are best controlled by a combination photosensor and time-based device to allow shut-off during the night. The astronomic-calculated sunset/time control can also be useful.
ZONE 3: ARCHITECTURAL / TIMED DUSK TO TIMED OFF
ARCHITECTURAL & LANDSCAPING DOCKS & BACK PARKING LOT
CONFERENCE ROOM
RECEPTION OFFICES
WAREHOUSE
OFFICES RESTROOM
RESTROOM
Building Facade, Landscape and Signage: Astronomic controls The third zone covers architectural lighting for building facade or landscape and signs. These are best controlled with an astronomic-calculated sunset/time control.
TORK 7
OFFICE OFFICE OFFICE
BREAK ROOM
TORK 8
PHOTOCONTROLS
FEATURES QUICK LOOK
COMMON FEATURES CHOICE OF PHOTOCELLS Cadmium sulphide, epoxysealed cells. Available in 1⁄2” and 1".
2100 SERIES
2110 SERIES
2000 SERIES
2001 SERIES
2020 SERIES
3000 SERIES
5000M SERIES
2005A SERIES
5200 SERIES
5737 SERIES
Page
13
14
15
16
17
18
19
20
21
23
Mounting
Conduit
Conduit
Conduit
Conduit
Conduit
Flush
Turn-Lock
Turn-Lock
Turn-Lock
Turn-Lock
Yes
Yes
Adjustable Swivel Housing
Die Cast Die Cast Zinc Aluminum
UV Stabilized UV Stabilized UV Stabilized Plastic Plastic Plastic
UV Stabilized Plastic
Lexan®
Lexan®
Lexan®
Lexan®
1 - 5 fc
1 - 5 fc
1 to 3 fc
1 to 3 fc
1.5 fc
5 fc
Turn ON Light Level
1 - 5 fc
1 - 5 fc
1 - 5 fc
1 - 5 fc
Adjustable light level adjustment
Yes
Yes
Yes
Yes
Turn OFF Ratio
3:1
3:1
3:1
3:1
3:1
3:1
5:1
3:1
1.5:1
1.5:1
Time Delay ON
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Instant
Instant
Instant
Time Delay OFF
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Light Sensor
CdS
CdS
CdS
CdS
CdS
CdS
CdS
CdS
Silicon Diode
Silicon Diode
CFL Compatible
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Surge Protection Photo Timer
TOUGH ENCLOSURES All conduit and flush mounted models utilize die-cast zinc, die cast aluminum, or genuine Lexan® materials. All turn-lock models utilize high impact UV stabilized polypropylene, ABS, PBT or Lexan® materials.
CHOICE OF MOUNTING ORIENTATION Models are available in fixed position or 180° swivel.
DEPENDABLE performance Built-in time delay prevents false switching due to light from passing highway vehicles, lightning, etc. Instant response is available in turn-lock models (5200 Series).
TURN-LOCKS MEET ANSI C136.10
Yes
All models meet the current ANSI requirements for locking-type prongs and color coded voltage designations. Locking prongs are solid brass.
TORK® Photocontrols are designed and manufactured with components which adhere to the highest industry standards. Trained personnel and in-process quality procedures ensure that every unit meets our strictest quality standards.
TORK 11
Color-Coded Dome Grey 105-130VAC Maroon 208-277VAC Blue 105-285VAC Yellow 480VAC Green 347VAC
TORK 12
2100 SERIES
SPECIFICATIONS
SPECIFICATION GRADE 1/2" CONDUIT MOUNTING DIE CAST ZINC PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required.
APPLICATIONS
SPECIFICATIONS
SPECIFICATION GRADE 1/2" CONDUIT MOUNTING DIE CAST ALUMINUM PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required.
TIME DELAY: ON and OFF.
TIME DELAY: ON and OFF.
CELL: Cadmium sulphide, epoxy-coated, 1" diameter.
CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter. Model 2117 is 1" cell.
CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position).
Parking lot lighting Building perimeter lighting Outdoor signage
2110 SERIES
LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C.
APPLICATIONS
CONTACTS: Remain closed between dusk and dawn (the unit fails in the ON position).
2117
Parking lot lighting Building perimeter lighting Outdoor signage
LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. (2117 #10AWG red and black).
2115 & 2116
POWER CONSUMPTION: Averages under 1 watt.
POWER CONSUMPTION: Averages under 1 watt.
TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).
TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 5 years.
WARRANTY: 5 years.
CONTACT RATINGS
CONTACT RATINGS
RATING CATALOG SWITCH WIRING DIAGRAMS NO. TUNGSTEN BALLAST
FEATURES OPERATION: Delay of up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.
2101
SPST
2000W
1800VA
2104
SPST
2000W
1800VA
2107
SPST
2000W
1800W
2000 SERIES
HOUSING: Heavy Duty die cast zinc housing and base. Gasketed for maximum weather protection.
WIRING DIAGRAMS
VOLTAGE 50-60Hz
2101
60012
120VAC
2104
60013
208-277VAC
2107
60031
120/277VAC
73866
62020
Mounting Bracket
2100 SERIESDie case aluminum housing HOUSING:
and base. Gasketed for weather protection. 2000 SERIES
SWITCH
2115
RATING TUNGSTEN
BALLAST
SPST
2000W
1800VA
2116
SPST
3470-4620W
2080-2770VA
2117*
SPST
3000W
3000VA
2100 WIRING SERIES
DIAGRAMS
ORDERING INFO
ORDERING INFO UPC CODE
OPERATION: Delay of up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
CATALOG NO.
FEATURES
CATALOG NO.
CATALOG NO.
UPC CODE
VOLTAGE 50-60Hz
2115
60032
120VAC
2116
60033
208-277VAC
2117*
60037
120VAC
73866
62020
Mounting Bracket
*Not UL or CSA rated.
PHOTOCONTROLS TORK 13
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 14
2000 SERIES
SPECIFICATIONS
1/2" CONDUIT MOUNTING FIXED POSITION, LEXAN® HOUSING WITH WEATHERPROOF SEALANT PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required.
2001 SERIES
SPECIFICATIONS
1/2" CONDUIT MOUNTING 180° SWIVEL, LEXAN® HOUSING PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required.
TIME DELAY: ON and OFF.
TIME DELAY: ON and OFF.
Cadmium sulphide, epoxy-coated, 1⁄2”
CELL: diameter.
APPLICATIONS
CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position).
Flood lamp Patio lamp Decorative lighting
LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C.
CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter.
APPLICATIONS
CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position).
Flood lamp Patio lamp Decorative lighting
LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C.
POWER CONSUMPTION: Averages under 1 watt.
POWER CONSUMPTION: Averages under 1 watt.
TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).
TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 5 years.
WARRANTY: 5 years.
CONTACT RATINGS RATING CATALOG WIRING DIAGRAMS SWITCH NO. TUNGSTEN BALLAST
FEATURES OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.
2000
SPST
2000W
1800VA
2000-2
SPST
3470-4620W
2080-2770VA
2000-7*
SPST
2000W
1800VA
HOUSING: All Lexan® enclosures are impact and vandal resistant. Translucent Lexan® Dome prolongs cell life by further screening out ultraviolet rays. Dome and base are ultrasonically welded for maximum strength.
WIRING DIAGRAMS 2000 SERIES
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
CONTACT RATINGS FEATURES OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.
CATALOG NO.
SWITCH
2001 2002
RATING TUNGSTEN
BALLAST
SPST
2000W
1800VA
SPST
3470-4620W
2080-2770VA
HOUSING: All Lexan® enclosures are impact and vandal resistant. Translucent Lexan® Dome prolongs cell life by further 2100 SERIES screening out ultraviolet rays. Dome and base are ultrasonically welded for maximum strength.
WIRING DIAGRAMS
Move Slide for Earlier or Later Turn ON
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
ORDERING INFO
ORDERING INFO
CATALOG NO.
UPC CODE
VOLTAGE 50-60Hz
CATALOG NO.
UPC CODE
VOLTAGE 50-60Hz
2000
60017
120
2001
60015
120
2000-2
60018
208-277
2002
60016
208-277
2000-7*
62023
120/277
73866
62020
Mounting Bracket
73866
62020
Mounting Bracket
• •
Red
Lamp
•
Move Slide for Earlier or Later Turn ON
•240V L2 • L1
*Model 2000-7 has a cadmium sulphide, 1” epoxy cell. Also UL listed and CSA certified.
Black Line White Neutral
(Black) Line (White)
(Red)
•
Lamp
For 277VAC: L1 - Line L2 - Neutral
PHOTOCONTROLS TORK 15
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 16
2020 SERIES
SPECIFICATIONS
1/2" CONDUIT MOUNTING 180° SWIVEL, LEXAN® HOUSING PHOTOCONTROL
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc.
ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc.
CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter.
CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter.
POWER CONSUMPTION: Averages under 1 watt.
Ideal for applications where it is essential to aim the photocell in an exact direction to sense natural light but avoid artificial light.
FLUSH MOUNTING LEXAN® HOUSING PHOTOCONTROL
TIME DELAY: ON and OFF.
LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C.
Flood and patio lamps Decorative lighting
SPECIFICATIONS
TIME DELAY: ON and OFF.
CONTACTS: Normally closed (the unit fails in the ON position).
APPLICATIONS
3000 SERIES
CONTACTS: Normally closed (the unit fails in the ON position).
APPLICATIONS Flush Mounting Model 3010
Pole lanterns Lawn lighting Walkways
LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. POWER CONSUMPTION: Averages under 1 watt.
TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).
TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 5 years.
WARRANTY: 5 years.
CONTACT RATINGS RATING
CATALOG
SWITCH NO. WIRING DIAGRAMS TUNGSTEN
CONTACT RATINGS FEATURES
CATALOG NO.
OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.
SWITCH
UPC CODE
VOLTAGE 50-60Hz
2021
60024
120
2022
60025
208-277
73866
62020
Mounting Bracket
BALLAST
SPST
2000W
1800VA
2022
SPST
3470-4620W
2080-2770VA
WIRING DIAGRAMS 120V MODELS
ORDERING INFO CATALOG NO.
TUNGSTEN
2021
HOUSING: All Lexan® enclosures are impact and vandal resistant, cover and base are ultrasonically welded for maximum strength. ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
FEATURES
RATING
Line
•Neutral •
(Black) (White)
(Red)
Lamp
L2
HOUSING & MOUNTING: Control housing is weather-resistant molded Lexan® with ultrasonically welded seams. MODEL 3000: Flush mounting through .6875” hole in post lantern or lighting fixture, 3⁄8” NPT, stem 3⁄4” long. Gasket and nut supplied. MODEL 3010: flush mounting into standard, raintight junction box. Includes plate and gasket to fit FS type outdoor junction box. ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
•
3000
SPST
2000W
1800VA
3002
SPST
3470-4620W
2080-2770VA
3006*
SPST
1500W
1200VA
3010
SPST
2000W
1800VA
WIRING DIAGRAMS 120V MODEL
LAMP LINE BLK 120V
RED
NEUT. WHITE
ORDERING INFO
208-277V MODELS
L1
OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.
BALLAST
Line
•
(Black)
•
(White)
240V Neutral
(Red)
•
For 277VAC L1 - Line L2 - Neutral
Lamp
CATALOG NO.
UPC CODE
VOLTAGE 50-60Hz
3000
60020
120
3002
60019
208-277
3006*
60026
347
3010
60021
120
208-277V MODEL For 277VAC: L1 - Line L2 - Neutral LINE BLK
LAMP RED
240V WHITE
*CSA certified only.
PHOTOCONTROLS TORK 17
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 18
5000M SERIES
SPECIFICATIONS
DELAYED RESPONSE UTILITY GRADE MOV SURGE ARRESTOR PHOTOCONTROL
ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-ON ratio is 5 max. TIME DELAY: ON and OFF. CELL: Cadmium sulphide photocell responds to the light spectrum near to that of a human eye. Resists effects of moisture and airborne contaminants.
APPLICATIONS
RELAY: Bi-metal provides positive snap action switching, reducing bounce and prolonging contact life.
For use on streets, highways and other luminaries equipped with locking type receptacles, where most stringent surge protection is needed.
SURGE ARRESTOR: 380 joule MOV (metal oxide varistor) exceeds ANSI and NEMA requirements. LOCKING PRONGS: Solid brass for maximum corrosion resistance and electrical conductivity. TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).
OPERATION: Delayed response prevents false switching due to light from vehicles or lighting, etc. STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards.
ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to TurnON is 3 average.
QUICK RESPONSE TURN-LOCK MOUNTING PHOTOCONTROL
TIME DELAY: Instant ON/3-5 seconds OFF. CELL: Cadmium sulphide photocell responds to the light spectrum near to that of a human eye. Resists effects of moisture and airborne contaminants.
APPLICATIONS
CONTACTS: Solid brass prongs for maximum corrosion resistance and electrical conductivity.
For use on streets, highways and other luminaries equipped with locking type receptacles, where instant response is required.
SURGE ARRESTOR: 360 joules MOV exceeds NEMA and ANSI requirements. RELAY: Positive snap action switching, reducing bounce and prolonging contact life.
Complies with ANSI C136.10 and EEI NEMA standards.
TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C).
FAIL MODE: ON.
FAIL MODE: ON.
WARRANTY: 3 years.
WARRANTY: 3 years.
CATALOG NO.
LIGHT SENSOR
5001M
RATING TUNGSTEN
BALLAST
1"
1200W
1800VA
5004M
1"
3470-4620W
2080-2770VA
5007M
1⁄2"
2000W 3470-4620W
1800VA 2080-2770VA
HOUSING: Lexan® UV Stabilized, permanent color with UV resistant clear acrylic window. Models 5026M and 5008M with polypropylene dome. Provides high impact, flammability resistance and electrically safe operation.
5008M*
1"
1000W
1800VA
5021M
1⁄2"
2000W
1800VA
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
5024M
1⁄2"
3470-4620W
2080-2770VA
5026M**
1⁄2"
1000W
1800VA
ORDERING INFO CATALOG NO.
UPC CODE
VOLTAGE 50-60Hz
COLOR
5001M
61012
105-130
Grey
5004M
61013
208-277
Maroon
5007M
61014
105-130/208-285
Blue
5008M*
61017
480
Yellow
5021M
61015
105-130
Grey
5024M
61016
208-277
Maroon
61045
SPECIFICATIONS
CONTACT RATINGS
FEATURES
5026M**
2005A, 2007A & 2008A
347
WIRING DIAGRAMS
2"
2 3/16"
Green
*Not UL listed or CSA certified. **CSA certified only.
Receptacle Surface
2 3/16"
FEATURES STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards.
CONTACT RATINGS
HOUSING: Polypropylene, UV Stabilized, permanent color with UV resistant clear acrylic window. Provides high impact, flammability resistance and electrically safe operation. ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
RATING
CATALOG NO.
TUNGSTEN
BALLAST
2005A
1000W
1800VA
2007A
1000W
1800VA
2008A*
1000W
1800VA
WIRING DIAGRAMS
ORDERING INFO CATALOG NO.
UPC CODE
VOLTAGE 50-60Hz
COLOR
2005A
62012
105-130
Grey
2007A
62013
105-285
Blue
2008A*
62014
400-550
Yellow
2"
2 3/16" Receptacle Surface
3 3/16"
*Not UL or CSA listed.
N
L1 Line (Black)
N
Load (Red) Neutral (White)
Load
105 to 285 volt single phase grounded supplies and loads
L1 Line (Black)
Load (Red) Neutral (White)
Load
105 to 285 volt single phase grounded supplies and loads
PHOTOCONTROLS TORK 19
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 20
5200 SERIES
5400 SERIES
SPECIFICATIONS
UTILITY GRADE ELECTRONIC WITH FAIL ON MODE PHOTOCONTROL
SPECIFICATIONS
6000 WATT CONTACTORS WITH TURN-LOCK PHOTOCONTROL
ON/OFF: Turn ON is 1.5 foot candle +/- 0.2 OFF/ON ratio is 1.5:1 average*.
RECEPTACLE: 3-prong turn-lock meets the requirements of EEI NEMA. POWER CONSUMPTION: Maximum 3 watts during daylight.
TIME DELAY: Instant ON/3-5 second OFF*. CELL: Silicon photosensor assures drift-free operation, turning on and off at the same light level consistently throughout the life of the unit.
APPLICATIONS
APPLICATIONS
CONTACTS: DC relay has positive snap action switching, reducing bounce and prolonging contact life. Fail ON for safety.
For use where the extreme accuracy and reliability of an electronic photocontrol is required and in the event of failure, light should stay ON for safety reasons.
CONTACT RATINGS For street lighting. Controls all lighting loads in excess of the capacity of the photoelectric control contacts.
SURGE ARRESTOR: 920 joule MOV (metal oxide varistor) exceeds ANSI and NEMA requirements. LOCKING PRONGS: Solid brass for maximum corrosion resistance and electrical conductivity. POWER CONSUMPTION: 1.0 watt average @ 120V. TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C).
CATALOG NO.
SWITCH
CONTACT RATING PER POLE
5403
DPST
3000W
5404
DPST
3000W
5404-3
DPST
3000W
5420
SPDT
3000W
FAIL MODE: ON.
WIRING DIAGRAMS
WARRANTY: 5 years. *Consult factory for other ratios and time delays.
120 VOLT CIRCUIT MODEL WHT 5403
WHT
LOAD
STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards. HOUSING: UV stabilized, ANSI colorcoded, high impact polypropylene dome. Cross-linked polypropylene gasket. High impact ABS base. High impact, UV stabilized acrylic window.
CONTACT RATINGS CATALOG NO.
LIGHT SENSOR
5231 5237
TUNGSTEN
BALLAST
Silicon Photosensor
1000W
1800VA
Silicon Photosensor
1000W
1800VA
2"
ORDERING INFO
WHT
78885
105-130VAC
5237
78886
105-305VAC
Line (Black)
Load (Red) Neutral (White)
Load
105-305 VAC single phase grounded supplies and loads
3 1/8"
120V N
120 VOLT CIRCUIT MODEL 5420
105 to 285 volt single phase grounded supplies and loads
CAS DIMENS
RED LOAD 1 BLUE LOAD 2
WHT H 120V
CATALOG NO.
UPC CODE
PHOTOCONTROL INCLUDED
VOLTAGE 50-60Hz
5403
60009
5021M
105-130VAC
5404
60010
120 VOLT CIRCUIT MODEL WHT 5403
5024M
5404-3
60011
5024M
5420
60014
5021M
BLK
LOAD 1 CLOSES AT DUSK, OPENS AT DAWN LOAD 2 CLOSES AT DAWN, OPENS AT DUSK
277 VOLT CIRCUIT MODEL 5404-3
208-240VAC BLK RED
WHT
BLK RED
WHT
WHT
BLK RED
BLK RED
208 or 240 VOLT CIRCUIT MODEL 5404
277VAC LOAD
WHT
LOAD
LOAD
105-130VAC
LOAD
LOAD
LOAD
LOAD
WHT
WHT
WHT
H
H
120V N
120V N
H
H 120V
277V N
120V/240V 3-WIRE SYSTEM
H H
277V/480V 4-WIRE SYSTEM
CASE DIMENSIONS
WHT RED
208V or 240V
208V/240V 4-WIRE SYSTEM
Add photoelectric control dimensions 2" high x 3" diameter
BLK
BLUE LOAD 2
N
Load
277V/48
BLK
RED LOAD 1
Neutral (White)
277V N
120V/240V 3-WIRE SYSTEM
WHT RED
N
L1 Load (Red)
H
H 120V
120 VOLT CIRCUIT MODEL 5420 Line (Black)
LOAD
WHT
H
120V N
120V 2-WIRE SYSTEM
120V 2-WIRE SYSTEM
N
LOAD
WHT
H
ORDERING INFO
L1
Receptacle Surface
VOLTAGE 50-60Hz
5231
N
LOAD
WHT
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
WIRING DIAGRAMS
2 3/16"
UPC CODE
HOUSING: Outdoor NEMA Type 3R. Beige enamel finish. Two 1⁄2”– 3⁄4” combination KO in bottom.
RATING
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
CATALOG NO.
BLK RED
FEATURES
WHT H 120V BLK
4-1/2" (114mm)
7-1/4" (184mm)
FEATURES
BLK RED
3-13/32" (87mm)
LOAD 1 CLOSES AT DUSK, OPENS AT DAWN LOAD 2 CLOSES AT DAWN, OPENS AT DUSK
PHOTOCONTROLS TORK 21
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 22
5737 SERIES
TORK 5737 T Z PHOTO-TIMER ®
SPECIFICATIONS
ON AT DUSK, OFF AT MIDNIGHT ON EARLY MORNING, OFF AT DAWN PHOTO-TIMERS
ON/OFF: Turn ON at dusk is 5.0 foot candle +/- 0.5 OFF/ ON ratio is 1.5:1 average.
THE MOST FLEXIBLE PHOTO-TIMER FOR MAXIMUM ENERGY SAVINGS AND ALL ON/OFF NEEDS!
TIME DELAY: Instant ON/3-5 seconds OFF. CELL: Silicon photosensor Midnight OFF: Allows user to adjust OFF time during the night. OFF time can be set for up to two hours before (for extra energy savings) or up to two hours after midnight. Use to stagger groups of lights to go OFF at different times during the night. Early Morning ON (537TZ only): Allows user to set number of hours after midnight (from 2-10 hours) that lights should turn back ON.
APPLICATIONS Offices Restaurant signage Billboards Landscape and yard lighting
No programming is required, the microprocessor tracks dusk and dawn times and automatically determines midnight, and corrects for Daylight Savings Time. It even re-learns and resets itself after a power outage, so that no maintenance is ever needed.
CONTACTS: DC Relay, normally closed. Provides chatter free operation. Solid brass Prongs for maximum corrosion resistance and electrical conductivity.
Ideal for situations when visible traffic is reduced – lights ON at dusk and OFF at 11pm or later, then on again for early morning illumination.
TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C). FAIL MODE: ON. WARRANTY: 3 years.
PHOTOCONTROL ACCESSORIES
FEATURES
FOR TURN-LOCK CONTROLS
OPERATION: Microprocessor tracks the dusk and dawn times with the seasons and automatically determines midnight, NO PROGRAMMING REQUIRED. Automatically "re-learns" and resets after power outage, eliminating costly maintenance. DST correction built in.
CONTACT RATINGS CATALOG NO.
SWITCH
5737TZ 5737TM
TUNGSTEN
BALLAST
SPST
1000W
1800VA
SPST
1000W
1800VA
2"
ORDERING INFO VOLTAGE 50-60Hz
5737TZ
62010
105-305VAC
62009
DEVICE
CATALOG NO.
5500
5500-OC 2 3/16"
UPC CODE
5500 replaces photocontrol to change light fixture to always ON. 5500-OC replaces photocontrol to change light fixture to always OFF. Durable materials and gasket provide longevity and weatherproof protection.
WIRING DIAGRAMS
ENERGY SAVINGS: Works with screw base CFLs and LED lamps.
CATALOG NO.
REPLACEMENT CAPS
RATING
HOUSING: UV stabilized, ANSI color-coded polypropylene dome. UV stabilized, clear acrylic window. ABS base. Cross-linked, polypropylene gasket.
5737TM
DUSK MIDNIGHTON OFF EARLY MO RNING ON DAWN OFF
The TORK Photo-timer Plus is the most flexible photocontrol ever, operating like a photocontrol AND a time switch! Ideal for retrofit without expensive rewiring. The unit turns the load ON at sunset and can be preset to turn the load OFF up to two hours before or two hours after midnight. It can also be set to turn the load back ON from two to ten hours after midnight and OFF at dawn.
2" Receptacle Surface
3 1/8"
N
Load (Red) Load
61132
DEVICE
Shorting cap 480VAC max 1800 Tungsten 1800VA Ballast Open cap 480VAC max (Black housing)
CATALOG NO.
UPC CODE
DESCRIPTION
2223
61025
Receptacle with Neoprene gasket
RECEPTACLE
RECEPTACLE
120-480V receptacle with color-coded #14 leads, mounting bracket and one mounting screw. DEVICE
120 or 277V 2 3/16"
Line (Black)
105-305 VAC single phase grounded supplies and loads
3 1/8"
61130
DESCRIPTION
L1
Neutral (White)
Receptacle Surface
105-305VAC
N
UPC CODE
RECEPTACLE
120-480V receptacle with color-coded #14 leads, neoprene gasket and two mounting screws.
CATALOG NO.
UPC CODE
DESCRIPTION
2224
61026
Receptacle and mounting bracket
120-480V receptacle with color-coded #14 leads, plastic housing, lock nut (with 1⁄2" NPT) and a mounting bracket. DEVICE
CATALOG NO.
UPC CODE
DESCRIPTION
2421
61021
Receptacle with plastic housing and bracket
L1 Line (Black)
Load (Red) Neutral (White)
Load
105-305 VAC single phase grounded supplies and loads
FOR 240V, N=L2, L1=L1
PHOTOCONTROLS TORK 23
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 24
ELECTROMECHANICAL TIME SWITCHES
FEATURES QUICK LOOK SERIES
PAGE NO.
CLOCK DIAL
MINIMUM SETTINGS (MINUTES) ON
OFF
SKIP A DAY
MANUAL SUNRISE/ OVERRIDE SUNSET
COMMON FEATURES EASY TO SET DIAL ASSEMBLY Tork’s 24 hour dial assembly allows the user to set the time switch more accurately, easily moving it by hand in small increments. Dial can provide up to 12 ON/OFFs per day with cycles as short as 20 minutes. AM and PM settings are easy to see by the light and dark areas of the dial.
MAX ON & OFF EVENTS PER DAY
RATINGS RESERVE (AMPS) POWER
SWITCH TYPES
29
24 Hour
15
15
Permanent
48
SPST
DPST
1100
31
24 Hour
20
75
Yes
12
SPST
DPST
7000
33
24 Hour
20
75
Yes
Yes
12
SPST
DPST
SPDT
DPDT
3PST
40
Available
7000Z
35
24 Hour
20 or 40 Minute Offset
Yes
Yes
Astronomic
1
SPST
DPST
SPDT
DPDT
3PST
40
Available
TZ
49
24 Hour
20 or 40 Minute Offset
Yes
Permanent by circuit
Astronomic
1
DPDT
3PST
20
Standard
W
43
7 Day
60
120
Yes
Yes
2
DPDT
3PST 4PST
40
Available
TW
47
7 Day
60
120
Yes
Permanent by circuit
2
DPDT
3PST
20
Standard
T900
45
7 Day
60
120
Yes
Permanent by circuit
2 SPDT 3 SPDT
20
Standard
1847A
41
24 Hour
20
75
Yes
1847AZ
41
24 Hour
1847AW
41
7 Day
20 or 40 Minute Offset 60
120
8000
37
24 Hour
15
8000
39
6, 12, 30 & 60 Min.
Varies by dial 6 sec. to 1 min.
WH2
40
24 Hour
20
TORK 27
15
75
Yes
Yes
Yes
Yes
Available
Yes
Photo Control
Astronomic
DPST
DPDT
For applications requiring many ON/OFF cycles per day, captive tabs on this dial tilt in and out just using your fingertip!
TU40
SPST
SPDT
CAPTIVE TABS – DUTY CYCLE DIAL
40
SPRING WOUND RESERVE
40
SPDT
2
12
SPDT, Momentary Contact
10
Available
1
SPDT, Momentary Contact
10
Available
2
SPDT, Momentary Contact
10
Available
48
SPDT
20
30/dial
SPDT
20
12
DPST
40
Available
FIELD UPGRADEABLE ASTRONOMIC DIALS All Tork 24 Hour Time Switches can be upgraded in the field to astronomic operation.
During power outages, precision spring mechanism takes over instantly and automatically. Keeps the mechanism on time up to 16 hours on 24 hour models and up to 24 hours on 7 day models. No resetting is needed after power resumes, and field installation is easy!
ENCLOSED MOTOR Time switch motors are enclosed to protect from dust and damage.
REMOVABLE DOOR Tork time switches feature removable doors to provide easy access for installation and wiring. TORK® Electromechanical Controls are designed and manufactured with components which adhere to the highest industry standards. Trained personnel and in-process quality procedures ensure that every unit meets our strictest quality standards.
TORK 28
TU40 SERIES
UNIVERSAL MULTI-VOLTAGE SAME ON/OFF TIMES EACH DAY 24 HOUR TIME SWITCH
NEW!
MORE WIRING SPACE!
CONTACT RATINGS
SPECIFICATIONS INPUT VOLTAGE: 120/208-240/277VAC, 60Hz (auto detection). TIMING ACCURACY: Line frequency.
VOLTAGE
NO
NC
General Purpose
120-277VAC
40A
30A
Inductive
120-277VAC
30A
15A
Ballast
120VAC 277VAC
30A 20A
10A 10A
Tungsten
120VAC
15A
120VAC 240VAC 120VAC 240VAC
1HP, 30FLA, 90LRA 2HP, 20FLA, 60LRA 720VA 720VA
Resistive
28VDC
20A
Max above 104°F
120-277VAC
30A
TERMINAL RANGE: #8 - #18 AWG. OPERATING TEMPERATURE: -31°F to 116°F (-35°C to +47°C).
APPLICATIONS
POWER CONSUMPTION: 6 watts maximum.
Lighting Pumps Signs Air conditioning Water heaters Fans
RATING
TYPE
ENCLOSURE: Polycarbonate Indoor/Outdoor NEMA 3R or -Y suffix metal indoor NEMA 1 enclosure. Both with lockable hasp standard (see page 153 for enclosure dimensions).
Motor Load Pilot Duty
¼HP, 12FLA, 30LRA ½HP, 12FLA, 33LRA 290VA 360VA
WIRING DIAGRAMS
DTU40 ORDERING INFO FEATURES MULTI-VOLTAGE: Automatic input voltage detection. EASY SET: Real time clock face and day/night markings for setting trippers.
Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application
CATALOG NO.
UPC CODE
TIMER SUPPLY (VAC) 60Hz
DRY CONTACTS (UNPOWERED)
TU40
24000
120/208-240/277
DPDT
TU40-Y
24001
120/208-240/277
DPDT
ENCLOSURE TYPE
Plastic Indoor/Outdoor NEMA 3R Metal Indoor NEMA 1
TIMER SUPPLY H
N
NC
NO
C
NC
LOAD L
N
N
NO
C
LOAD L
N
L
Typical Wiring Diagram, 208-240 VAC Application
SCHEDULING: Minimum ON is setting 15 minutes. Dial has 96 captive trippers.
TIMER SUPPLY H
4 in 1 CONTACTS: DPDT can also wire as SPST, SPDT, & DPST.
N
NC
NO
C
NC
NO
C
LOAD
BYPASS SWITCH: Sets timer to permanent ON, OFF or timer operation.
L1
L2
L1
VACATION MODE: Set timer OFF with no change of tripper settings.
L2
DTWH40
INDICATING LIGHTS: Power ON green and load ON red and LED indicators.
Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application
TIMER
SPECIFICATION WRITER’S GUIDE SUPPLY Furnish and install, where shown, a TORK time switch with 24 hour dial. The Time switch input shall be multi-voltage input 120/208/240/277VAC. Time Switch H N NC NO C NC NO C contacts shall be capable of switching 40 amperes per pole continuously up to 277 volts, and shall be DPDT, covering SPST, SPDT and DPST applications as LOAD96 trippers permits LOAD required. Captive ON/OFF trippers shall accomplish 1-48 operation per day. 15 minutes switching changes. Enclosure shall be Heavy duty lockable plastic Indoor/Outdoor NEMA 3R surface type, finished in beige, with combination 1⁄2”, 3⁄4” knockouts on bottom sides and back. Provisions shall be N L shall be TORK Model TU40_. made for positive padlocking. Terminal shall be capableL of receiving #8-#18N AWGL wire. The TimeN Switch Typical Wiring 208-240 VAC Application Typical Diagram, Wiring Diagram, 240VAC TIMER SUPPLY H
ELECTROMECHANICAL CONTROLS TORK 29
N
NC
NO
C
NC
NO
C
LOAD
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
L1
L2
L1
L2 TORK 30
1100 SERIES
SAME DAY ON/OFF TIMES EACH DAY 24 HOUR TIME SWITCH
SPECIFICATIONS
CONTACT RATINGS
INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz, varies by model.
TYPE
APPLICATIONS Lighting Pumps Signs Air conditioning Water heaters Fans Automatic ON/OFF control when operation is required at the same time every day.
FEATURES SCHEDULING: Minimum ON is setting 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes.
ELECTROMECHANICAL CONTROLS TORK 31
ENCLOSURE TYPE
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60Hz
OUTPUT CONTACTS
1101
10011
120
SPST
1101-N
10040
120
SPST
1101-NC
10053
120
SPST
1101-O
10015
120
SPST
Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3
1101-M
10022
120
SPST
Mechanism
1101-M-IAP
10052
120
SPST
1101-7
10033
347
SPST
1102
10012
208-277
SPST
1102-N
10045
208-277
SPST
1102-O
10046
208-277
SPST
Mechanism and mounting plate Metal Indoor NEMA 1 Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3
1102-M
10035
208-277
SPST
Mechanism
1103
10013
120
DPST
1103-N
10041
120
DPST
1103-NC
10054
120
DPST
1103-O
10016
120
DPST
Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3
1103-M
10023
120
DPST
Mechanism
1104
10014
208-277
DPST
1104-N
10042
208-277
DPST
1104-NC
10055
208-277
DPST
1104-O
10017
208-277
DPST
Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3
1104-M
10014
208-277
DPST
Mechanism
1104-M-IAP
10051
208-277
DPST
Mechanism and mounting plate
Replacement Trippers
Order #P47 for a pair of ON/OFF trippers
Replacement Motor
#101 (120V) & #201 (208-277V) For Astronomic Conversion: Order #Z KIT
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
40A
TERMINAL RANGE: #8 - #14 AWG.
Resistive
OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
Tungsten
120VAC
40A
Inductive
120, 277VAC single phase
20A
Pilot Duty
120 -277VAC
1000VA
Motor
120VAC 240VAC
2HP 5HP
POWER CONSUMPTION: 3 watts maximum.
ORDERING INFO
120 -277VAC single phase 120 -277VAC single phase
General Purpose
TIMING ACCURACY: Line frequency.
CONTACT RATING
VOLTAGE
ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).
40A
Model 1101-7 is 30 AMP inductive at 347 volts and CSA only.
OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows any 1100 series to fit into an Intermatic case.
WIRING DIAGRAMS 1101 & 1102 (SPST)
1103 (DPST)
M
Removable Bridge
M
L L
1
H
2
X
LOAD
N For separate motor terminals remove bridge from terminals 1 & L.
M
L H H TYPICAL FOR 240V SUPPLY
1
H N H
LOADS
M
1104 (DPST) (Both)
2
X LOAD
2
X
1
Must be same phase H
L
H
1
X
2
LOAD
LOAD
N TYPICAL FOR 277V SUPPLY
Typical for double pole Cut motor lead at 1
SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with 24 hour dial. The time switch shall be powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination 1⁄2”, 3⁄4” knockouts on bottom, both sides and back. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model 11_ _ (11_ _–_, etc, to fit requirement).
TORK 32
7000 SERIES
CONTACT RATINGS
SPECIFICATIONS
WITH SKIP-A-DAY FEATURE RESERVE POWER OPTIONAL 24 HOUR TIME SWITCH
TYPE
INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz varies by model. TERMINAL RANGE: #8 - #14 AWG.
Resistive
120 -277VAC single phase 120 -277VAC single phase
OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
Tungsten
120VAC
40A
Inductive
120, 277VAC single phase
20A
Pilot Duty
120 -277VAC
1000VA
Motor
120VAC 240VAC
2HP 5HP
General Purpose
TIMING ACCURACY: Line frequency.
CALIFORNIA Title 24
APPLICATIONS
ASHRAE 90.1
POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.
Lighting Heating Pumps Air conditioning Signs
ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).
NEW!
FEATURES NEW!
SCHEDULING: Minimum ON setting is 20 minutes with minimum OFF setting at 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. SKIP-A-DAY: Omit operations on any day with a 7-spoke wheel marked with days of week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.
ELECTROMECHANICAL CONTROLS TORK 33
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60Hz
OUTPUT CONTACTS
7100
10001
120
SPST
7102
10002
208-277
SPST
7200
11001
120
DPST
7200-O
10512
120
DPST
7202
11002
208-277
DPST
7202-O
10509
208-277
DPST
7300 7302
12001 12002
120 208-277
3PST 3PST
7120
13001
120
SPDT
7122
13002
208-277
SPDT
7220
14001
120
DPDT
7222
14002
208-277
DPDT
ENCLOSURE TYPE
Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1
Metal Indoor NEMA 1 Metal Indoor 7202L 19004 208-277 DPST NEMA 1 Metal Indoor/Outdoor 7300L 19005 120 3PST NEMA 3 Metal Indoor/Outdoor 7302L 19006 208-277 3PST NEMA 3 Metal Indoor 7120L 19007 120 SPDT NEMA 1 Metal Indoor 7220L 19009 120 DPDT NEMA 1 Metal Indoor 7222L 19011 208-277 DPDT NEMA 1 Replacement Order #P49 for a pair of ON/OFF per dial. Additional ON/OFF trippers per Trippers dial order #P47. 3 omitting screws #53005 supplied. Replacement #101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46 (208-277V). For Astronomic Conversion: Order #Z KIT for 7000 Series. Motor 19003
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
120
40A
WIRING DIAGRAMS 7100 SPST
7200 DPST
7100 SPST
M
M
M
7300 3PST
7200 DPST
L
L
L
2 L
H
H
N
X L
1
2
LOAD
H N H
7120 SPDT
2
X
M X
1
L
LOAD
LOAD
H N H
2 L
3
L
L
L
5 L
6
L
DPST
H
1
LOAD
X L H
A
N
LOAD
B
N
2 1
L H
LOAD
X
LOAD
A
B
N
2H H N H
1
L N
3 LOAD
N
5 LOAD
6 LOAD LOAD
LOAD
7302 3PST
7120Z (SPDT) M
M
X
L
H
H
4
LOAD
L
1
3
M
M M
L
2
N
7220 DPDT (DPST) 7200Z 7220 DPDT
M
X
1
4
L LOAD
N
7120 SPDT
M
2
LOAD
LOAD
LOAD
N
1
7300 3PST
M
M
WITH RESERVE POWER 7200L
40A
OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows any 7100 and 7200 series (except “L” models) to fit into an Intermatic case.
ORDERING INFO
Automatic ON/OFF control when operation is required at the same time every day, with optional versatility of one to six days omission.
CONTACT RATING
VOLTAGE
5 N
2
2
X
LOAD
L
4
H X
1LOAD LOAD
LOAD
3
LOAD LOAD
2
L
N 5 H
LOAD
N
L
1
3H
2
L
4
H
L
6 LOAD
LOAD
N
1
X
2
H
LOAD
5 N
4
X
LOAD
LOAD
LOAD A
LOAD B
N
H
FOR USE WITH 3 PHASE 4-WIRE N 120/208V SYSTEMS.
SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with 24 hour dial and day-omitting device. The time switch shall be powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination 1⁄2”, 3⁄4” knockouts on bottom, both sides and back. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time Switch shall be TORK Model 7_ _ _ (to fit requirement). FOR RESERVE POWER (MODELS WITH SUFFIX “L”): Spring-driven reserve shall be provided sufficient to operate the time switch contacts at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.
TORK 34
7000Z SERIES
ADJUSTS TO DAILY CHANGES IN SUNSET TIMES!
WITH SKIP-A-DAY FEATURE RESERVE POWER OPTIONAL ASTRONOMIC TIME SWITCH
CONTACT RATINGS
SPECIFICATIONS
TYPE
INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz, varies by model. TERMINAL RANGE: #8 - #14 AWG.
Resistive
120 -277VAC single phase 120 -277VAC single phase
OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
Tungsten
120VAC
40A
Inductive
120, 277VAC single phase
20A
Pilot Duty
120 -277VAC
1000VA
Motor
120VAC 240VAC
2HP 5HP
General Purpose
TIMING ACCURACY: Line frequency.
CALIFORNIA Title 24
APPLICATIONS
ASHRAE 90.1
POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.
Parking lots Walkways Outdoor signage Window displays Canopy lighting Landscape lighting
ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).
Automatic ON at dusk, OFF at dawn. Control of outdoor lighting.
42°
ORDERING INFO
SKIP-A-DAY: Omit operations on any day with a 7 spoke wheel marked with days of the week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.
CATALOG NO.
7200Z–* 7202Z–* 7300Z–* 7302Z–* 7120Z–*
UPC CODE
INPUT SUPPLY (VAC) 60Hz
** **
120 208-277
** **
120 208-277
**
120
OUTPUT CONTACTS
DPST DPST 3PST 3PST SPDT
ENCLOSURE TYPE
Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Noryl® Indoor/Outdoor NEMA 3R
WITH RESERVE POWER 7200ZL–*
**
120
DPST
7202ZL–*
**
208-277
DPST
7300ZL–*
**
120
3PST
7302ZL–*
**
208-277
3PST
7120ZL–*
**
120
SPDT
7122ZL–*
**
208-277
SPDT
Replacement Motor
Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R
#101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46 (208-277V)
*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45). **Consult factory for UPC number.
ELECTROMECHANICAL CONTROLS TORK 35
40A
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
40° H N H
38°
WASHINGTON
OREGON
L
7120Z (SPDT)
M
M
45°
ASTRONOMIC SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/- 20 or 40 minutes from both sunset and OFF times. Available from 18° - 45° northern latitudes.
40A
WIRING DIAGRAMS ASTRONOMIC LATITUDE ZONES 7200Z (DPST) 7302 3PST
FEATURES
CONTACT RATING
VOLTAGE
X
2
UTAH
LOAD
WISCONSIN
KANSAS
L L
3
ILLINOIS
ARIZONA
L
NEW MEXICO
IND
MISSOURI
ARKANSAS
N
L
RHODE ISLAND
H
DELAWARE MARYLAND
VIRGINIA
6
LOAD
LOAD B
1
N
H N H
7302 3PST
FLORIDA
18° HAWAII
LOAD A
N
LOAD
L
2
X
2
LOAD
LOAD
GEORGIA
LOUISIANA
30°
X
H
FOR USE WITH 3 PHASE 4-WIRE 7200Z (DPST) 120/208V SYSTEMS.
MEXICO
1
CONNECTICUT NEW JERSEY
NORTH CAROLINA SOUTH LOAD CAROLINA
ALABAMA
MASS
PENNSYLVANIA
4
OHIO
KENTUCKY
TENNESSEE
MISS TEXAS
NH
WEST VIRGINIA
5 OKLAHOMA
VT
2 NEW YORK
CALIFORNIA
34°
X
1
M
MAINE
IOWA
COLORADO
LOAD
M
MICHIGAN
L
WYOMING NEBRASKA
NEVADA
MINN
SOUTH DAKOTA
IDAHO
1
NORTH DAKOTA
MONTANA
7200Z (DPST)
18° PUERTO
M
7120Z (SPDT)
M
M
RICO
L
L
1
X
L
H N H
LOAD
1
X
2
2
LOAD
3
L
4
5
6 LOAD
X
LOAD A
LOAD B
2 H
H
L L
1
LOAD
LOAD
N
N
N
FOR USE WITH 3 PHASE 4-WIRE 120/208V SYSTEMS.
SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur automatically at sunset (in city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustability of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor – Noryl® – 3PST is NEMA 3 metal indoor/outdoor. Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time switch shall be TORK Model 7_ _ _Z (to fit requirement). FOR RESERVE POWER (Add Suffix L): Spring driven reserve shall be provided sufficient to operate the time switch contacts for at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.
TORK 36
8000 SERIES
CONTACT RATINGS
SPECIFICATIONS
MANY DAILY ON/OFF OPERATIONS PER DAY DUTY CYCLE 24 HOUR TIME SWITCH
INPUT VOLTAGE: 120, 208-277VAC or 480VAC, 60Hz, varies by model. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG.
ORDERING INFO ENCLOSURE TYPE
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60Hz
OUTPUT CONTACTS
8001
70001
120
SPDT
8001-N
70025
120
SPDT
8001-NC
70009
120
SPDT
Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R w/ clear Lexan® cover
8001-LC/WB
70010
120
SPDT
Mechanism and bracket
8001-O
70029
120
SPDT
8004
70002
208-277
SPDT
8001U
70003
480/120 Trans.
SPDT
NEW!
8001U-N
70014
480/120 Trans.
SPDT
NEW!
8001U-O
70011
480/120 Trans.
SPDT
Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3
DUTY CYCLE: Adjustable from 1⁄2, 1, 2, 3, 4, 6, 12, and 24 hours.
24 HOUR WITH 7 DAY OMIT 70005
120
SPDT
8007-O
70012
120
SPDT
8008
70006
208-277
SPDT
NEW!
8007U
70008
480/120 Trans.
SPDT
NEW!
8007U-0
70028
480/120 Trans.
SPDT
Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3
24 HOUR WITH 7 DAY OMIT & RESERVE POWER 8007L
70015
120
SPDT
8008L
70016
208-277
SPDT
Metal Indoor NEMA 1 Metal Indoor NEMA 1
24 HOUR WITH 14 DAY OMIT 8007V
70007
120
SPDT
Metal Indoor NEMA 1
SPDT
Metal Indoor NEMA 1
24 HOUR WITH 14 DAY OMIT & RESERVE POWER 8007VL Replacement Motor
TORK 37
120 or 240VAC 480VAC
20A 20A
Motor
120VAC
3/4 HP
OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows 8001 & 8004 to fit into an Intermatic case.
WIRING DIAGRAMS
70017
120
M
ALL SPDT MODELS
C L
H
8007
SKIP-A-DAY: Some models include 7 day or 14 day wheel to omit selected days of the week.
ELECTROMECHANICAL CONTROLS
Resistive
ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).
8001-N
FEATURES
OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.
CONTACT RATING
POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.
For one or multiple daily ON/OFF operations.
SCHEDULING: Minimum ON setting is 15 minutes with minimum OFF setting at 15 minutes. Dial accommodates up to 96 captive tabs.
VOLTAGE
OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
APPLICATIONS Duty cycling Ventilating fans Pumping Irrigation Process control Laboratory experiments
TYPE
120VAC N
NC
NO 2
LOAD 2 CLOSED WITH TAB OUTWARD
LOAD 1 CLOSED WITH TAB INWARD
SPECIFICATION WRITER’S GUIDE The time switches shall be of duty cycle type, capable of programming at 15 minute intervals of the day. Scheduled tabs shall be captive on the dial, and shall be easily set by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the field. FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007 or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.
#101(120V) & #201 (208-277V). For “L” models #36 (120V) & #46 (208-277V)
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 38
8000 SERIES
SPECIFICATIONS
MULTIPLE ON/OFF CYCLES PER DAY REPEATING VARIABLE CYCLE TIME SWITCH
INPUT VOLTAGE: 120VAC, 60Hz.
APPLICATIONS
24 HOUR WATER HEATER TIME SWITCH
INPUT VOLTAGE: 208 – 250V 60 Hz. TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #8 - #14AWG.
TERMINAL RANGE: #8 - #14AWG.
OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
REPLACEMENT TRIPPERS: #P49 for a pair with one ON and one OFF per dial for additional ON/OFF trippers per dial order #P47. 3 omitting screws #53005 supplied. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).
For one or many daily ON/OFF operations.
SPECIFICATIONS
TIMING ACCURACY: Line frequency.
POWER CONSUMPTION: 3 watts maximum.
Duty cycling Ventilating fans Pumping Irrigation Process control Laboratory experiments
WH2
APPLICATIONS
SAVE ENERGY!
POWER CONSUMPTION: 3 watts maximum.
Avoid utility peak rates Turn off when not needed
Automatic ON/OFF control of electric water heaters. Schedules the water heater to turn ON only when needed, avoiding energy waste when hot water is not needed.
ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).
CONTACT RATINGS CONTACT RATINGS
FEATURES SCHEDULING: 60 captive tabs per dial with minimum ON/OFF settings: – 60 minute dial with 1 minute tabs. – 30 minute dial with 30 second tabs. – 12 minute dial with 12 second tabs. – 6 minute dial with 6 second tabs.
TYPE
VOLTAGE
CONTACT RATING
Resistive
120 or 240VAC 480VAC
20A 20A
Motor
120VAC
3/4 HP
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60Hz
OUTPUT CONTACTS
TYPE
8601
70034
120
SPDT
60 Minute
8301
70033
120
SPDT
30 Minute
8121
70032
120
SPDT
12 Minute
C L
H
120
SPDT
6 Minute
120VAC N
Replacement For 8601 #102, for 8301 #108, for 8121 #107, and for 8061 #105. Motor Replacement #P49 for a pair with one ON and one OFF per dial for additional ON/OFF Trippers trippers per dial order #P47. 3 omitting screws #53005 supplied.
ELECTROMECHANICAL PHOTOCONTROLS CONTROLS TORK 39
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
NC
TYPE
VOLTAGE
CONTACT RATING
Resistive
208-277VAC
40 A, 10,000W
Replacement Motor
#201 (208-277V)
Replacement Trippers
Order #P47 for a pair of ON/OFF trippers
EXTERNAL MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes.
M
ALL SPDT MODELS
ORDERING INFO
70031
SCHEDULING: Minimum ON is setting 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs. 3 pairs of trippers supplied.
WIRING DIAGRAMS
DUTY CYCLE: Settings of 1⁄60 th of dial speed.
8061
FEATURES
WIRING DIAGRAMS TYPICAL FOR 240 VOLT SUPPLY
ORDERING INFO
NO 2
LOAD 2 CLOSED WITH TAB OUTWARD
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60Hz
OUTPUT CONTACTS
ENCLOSURE TYPE
WH2
70042
208-250
DPST
Metal Indoor NEMA 1
M
H H
L
1
2
X LOAD
LOAD 1 CLOSED WITH TAB INWARD
TORK 40 40 TORK
1800 SERIES
CONTACT RATINGS
SPECIFICATIONS
FOR MECHANICALLY HELD CONTRACTORS AND LOW VOLTAGE REMOTE CONTROL MOMENTARY CONTACT TIME SWITCH
INPUT VOLTAGE: 120VAC or 208-277VAC, 60Hz, varies by model. TIMING ACCURACY: Line frequency.
TYPE
VOLTAGE
CONTACT RATING
General Purpose
24-277VAC
10A
Pilot Duty
24-277VAC
360VA
TERMINAL RANGE: #12 - #22AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
APPLICATIONS
CALIFORNIA Title 24
Mechanically-held contactors 3-wire momentary lighting systems Remote station switching
POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.
ASHRAE 90.1
ENCLOSURE: NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).
WIRING DIAGRAMS
ORDERING INFO WASHINGTON
FEATURES
CATALOG NO.
SCHEDULING: Choice of three types.
1847A
24 HOUR SKIP-A-DAY: Minimum ON setting is 20 minutes with minimum OFF setting at 75 minutes. Dial accommodates up to 12 pairs of trippers. Omit operations on any day with a 7 spoke wheel marked with days of week.
1848A
UPC CODE
INPUT SUPPLY (VAC) 60Hz
52001 52014
120 208-277
7 DAY SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial will accomodate up to 2 pairs on ON/ OFF trippers per day - 7 pairs are supplied. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
TORK 41
SPDT SPDT
TYPE
42°
24 Hour
OREGON
NORTH DAKOTA
MONTANA
MINN
MICHIGAN
WYOMING
**
120
SPDT
Astronomic
1847AW
52005
120
SPDT
7 Day
WITH RESERVE POWER 1847AL
52006
120
SPDT
24 Hour
1847AZL*
**
120
SPDT
Astronomic
1847AWL
52010
120
SPDT
7 Day
Replacement Trippers
For 24 hour models order #P49 for a pair ON/OFF per dial. Additional ON/OFF trippers per dial order #P47. 3 omitting screws #53005 supplied. 7 day models order #P69 for 7 pairs of ON/OFF trippers.
Replacement Motor
#101(120V) & #201 (208-277V). For “L” models #36 (120V)
*Add degrees latitude to complete number (18, 30, 34, or 42). **Consult factory for UPC number.
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
MAINE
WISCONSIN
SOUTH DAKOTA
IDAHO
UTAH
IOWA
NEW YORK
KANSAS
34°
IND
COLORADO
PENNSYLVANIA
OHIO
KENTUCKY OKLAHOMA ARIZONA
NEW MEXICO
ARKANSAS
TIMING MOTOR
120VAC, 60HZ
L
TENNESSEE
MASS RHODE ISLAND CONNECTICUT
DELAWARE MARYLAND
VIRGINIA
CLOSE COMMON
N
NEW JERSEY
WEST VIRGINIA
MISSOURI
CALIFORNIA
ON
VT NH
ILLINOIS NEVADA
C
MECHANICALLY-HELD CONTACTOR
NEBRASKA
24 Hour
1847AZ*
OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.
ELECTROMECHANICAL CONTROLS
OUTPUT CONTACTS
ON
OPEN
NORTH CAROLINA SOUTH CAROLINA
MISS ALABAMA
TEXAS
ASTRONOMIC SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/20 or 40 minutes from both sunset and OFF times.
OFF
ASTRONOMIC LATITUDE ZONES
OFF
GEORGIA
LOUISIANA
MOMENTARY PUSH BUTTON
MEXICO
30°
FLORIDA
18° HAWAII
18° PUERTO RICO
SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a Momentary Contact time switch. Time switch shall have dial of the (24 hour with day omitting device) (Astronomic with day omitting device) (7 day calendar) type, which shall be suitable to operate mechanically-held contactor of maximum size. Terminal board shall enable fast and correct installation using screw terminals for up to #12AWG wire. Timing motor terminals shall be completely independent from momentary switching circuit. Spring driven reserve mechanism shall be provided sufficient to operate time switch controls at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. Time switch shall include solid state circuit to provide a switch closure not in excess of two seconds on both ON and OFF contactor coil terminals at such times as are set on dial: these settings to be made with removable trippers which can be added and removed without tools (except the astronomic dial). Contactor coil circuits shall be suitable for 10 Amp @ 24-277 VAC, 360 VA. Enclosures shall be NEMA 1 surface (or see other mountings), with provision for positive padlocking. Time switch shall be TORK Model 1847AL, 1848A, (AZL), (AWL).
TORK 42
W SERIES
CONTACT RATINGS
SPECIFICATIONS
DIFFERENT SCHEDULES EACH DAY 7 DAY TIME SWITCH
TYPE
INPUT VOLTAGE: 120 or 208-277VAC, 60Hz, varies by model.
Resistive
TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
CALIFORNIA Title 24
APPLICATIONS
ASHRAE 90.1
Heating Air conditioning Display lighting Ventilating systems Lighted signage Storefront lighting
POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.
40A
120VAC
40A
Inductive
120, 277VAC single phase
20A
Pilot Duty
120 -277VAC
1000VA
Motor
120VAC 240 VAC
2HP 5HP
ORDERING INFO CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60Hz
OUTPUT CONTACTS
W100
30001
120
SPST
33001
120
ENCLOSURE TYPE
WIRING DIAGRAMS
W100 (SPST)
W100 (SPST)
SPDT
M
W200 W202
FEATURES
31001 31011
120 208-277
SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. Models W400A and W402A offer minimum ON/OFF settings of 31⁄2 hours. 7 day calendar dial accommodates up to 2 pairs of ON/OFF trippers per day – 7 pairs are supplied. SKIP-A-DAY: Omit operations on any day. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 24 hours during power outage.
W222 W300 W300-O W302
34001 34011 32001 32003 32002
120 208-277 120 120 208-277
L
Metal Indoor NEMA 1
L
L
L
L XH N H
LOAD 1
N
2
LOAD
H N H
LOAD
2
X
1
2
H L
N
DPDT
1
LOAD
2
L
5
L
4
5
L
N
H
3PST 3PST
35001
120
4PST
W402A
35002
208-277
4PST
Equipment (4PST) W400A Ground
Equipment Ground
LOAD
LOAD
Clock Motor Supply
3 5
6
7
L
X
1
2
H
2
H
B
X
LOAD
1
LOAD
N
N H
N
L
LOAD
B
N
N
2
3
5
LOAD
LOAD
N
4
L
H 3 LOAD
N
5
4
LOAD
LOAD
H N
W202 (DPST)
1
2
3
4
4
MOTOR
MOTOR
MOTOR L
7
8
8
B
H
1
L
6
H
LOAD
H
5
LOAD
L LOAD
A
2
W202MOTOR (DPST) A
2
X
X
M
M A Motor1 Clock Supply
LOAD
A
LOAD
1
L
H
H
Metal Indoor NEMA 1
1
LOAD
1
H
H
6
W400A (4PST)
Metal Indoor/Outdoor NEMA 3
L
LOAD
N
3PST
M
4
L
6 LOAD
2
3
L
LOAD
3
L
LOAD
2
X
M
W220 (DPDT)
M
M
L X
1
W220 (DPDT)
W120 (SPDT)
W120 (SPDT)
DPDT
W400A
H
L
Typical for 208-240VAC
1
X
LOAD
LOAD 1
X
LOAD
H
2
LOAD
2
LOAD
Typical for 277VAC
H
Typical for 208-240VAC
Typical for 277VAC
B
WITH RESERVE POWER W220L
39009
120
DPDT
W222L
39010
208-277
DPDT
W300L
39005
120
3PST
W302L
39006
208-277
3PST
W400AL
39007
120
4PST
Supply Supply
Metal Indoor NEMA 1
Replacement Trippers
Order #P69 for 7 pairs of ON/OFF trippers except W400 series use #P69i.
Replacement Motor
#101 (120V) & #201 (208-277V). For W400 series units order #101i (120V) & #201i (208-277V). For “L” models order #36 (120V) and #46 (208-277V), except W400 series consult factory.
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
M
M
H
W220
W300 (3PST)
W300 (3PST)
M
M
DPST DPST
W200 (DPST)
W200 (DPST)
M
TORK 43
40A
Tungsten
ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp. Other enclosures include metal Indoor/ Outdoor NEMA 3 with suffix "O" (see page 153 for enclosure dimensions).
W120
ELECTROMECHANICAL CONTROLS
120 -277VAC single phase 120 -277VAC single phase
General Purpose
TIMING ACCURACY: Line frequency.
CONTACT RATING
VOLTAGE
To Load(s) To Load(s)
SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, TORK time switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON/ OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402 offer minimum ON and OFF settings of 3.5 hours. Enclosure shall be NEMA 1 surface, finished in baked beige enamel, with combination 1⁄2” - 3⁄4” knock-outs on bottom and both sides. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model W_ _ _ (to fit requirement). FOR RESERVE POWER (Add suffix L): Spring-driven reserve shall be provided sufficient to operate the Time Switch contacts at least 24 hours after power failure (16 hour reserve power on 4PST models). On restoration of power, time switch shall transfer to synchronous motor driven and automatically rewind reserve power unit.
TORK 44
LOAD
T900 SERIES
INPUT VOLTAGE: 120 or 208-277VAC, 60 Hz, varies by model. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG.
APPLICATIONS
TYPE
VOLTAGE
CONTACT RATING
General Purpose
120/277VAC
20A
Motor
120VAC 240VAC
1HP 2HP
OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
CALIFORNIA Title 24 ASHRAE 90.1
Parking lot lighting HVAC Display lighting Security lighting Lighted signage Storefront lighting
CONTACT RATINGS
SPECIFICATIONS
PHOTOELECTRIC & 7 DAY CONTROL COMBO DIFFERENT SCHEDULES EACH DAY RESERVE POWER STANDARD 2 & 3 CIRCUIT LIGHTING CONTROL CENTERS
POWER CONSUMPTION: 5 watts maximum. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp. Other enclosures include cover for access to by-pass switches with suffix "E" or Indoor/Outdoor NEMA 3 metal with suffix "O" (see page 153 for enclosure dimensions).
Optional "E" cover
Model 2101 supplied with unit.
WIRING DIAGRAMS T930L T930L
T920L T920L
ONLYCIRCUITS CIRCUITS1 1AND AND2 2ARE AREINCLUDED INCLUDEDININT920L T920L ONLY
ORDERING INFO FEATURES
CATALOG NO.
SCHEDULING: CIRCUIT 1: ON automatically at dusk, OFF at individual preset times each day, including skipping days when desired. Unit can be set to turn ON before dawn for early morning lighting. CIRCUIT 2: ON at dusk, OFF at dawn automatically, daily. CIRCUIT 3: Individual daily ON and OFF settings at desired times, including skipping any desired day or days Minimum ON is setting 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial will accommodate up to 2 pairs of ON-OFF trippers per day – 7 pairs are supplied. SKIP-A-DAY: Omit operations on any day.
UPC CODE
INPUT SUPPLY (VAC) 60Hz
41033
120
2 SPDT
T920L-E
41034
120
2 SPDT
T920L-O
41035
120
2 SPDT
T930L
41055
120
3 SPDT
T930L-E
41056
120
3 SPDT
T930L-O
41057
120
3 SPDT
Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor/outdoor NEMA 3
ON ON OFF OFF
ON ON OFF OFF
AUTO AUTO
AUTO AUTO
SWITCH TIMETIME SWITCH OFF OFF ON ON
MM
C C
NOTE: NOTE: Contacts 7-12 Contacts 7-12 unpowered. areare unpowered.
RELAY RELAY
PHOTOELECTRIC PHOTOELECTRIC CONTROL CONTROL
ON ON OFF OFF
ON ON OFF OFF
ON ON OFF OFF
AUTO AUTO
AUTO AUTO
AUTO AUTO
NOTE: NOTE: Contacts 4-12 Contacts 4-12 unpowered. areare unpowered.
RELAY RELAY
C C PHOTOELECTRIC PHOTOELECTRIC CONTROL CONTROL
MM
CONTACTOR CONTACTOR CONTROL CONTROL CIRCUIT LINELINE CIRCUIT
RED RED WHITE WHITE BLACK BLACK
L1 L1 OPEN CLOSEOPEN LINELINE CLOSE
1 1
CONTACTOR CONTACTOR CONTROL CONTROL CIRCUIT CIRCUIT
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 H 120V H 120V N N 60C 60C LINELINE
TIME TIME SWITCH SWITCH
TO DAWN SAFETY LIGHTS DUSKDUSK TO DAWN SAFETY LIGHTS (PHOTOCELL - PHOTOCELL (PHOTOCELL ON - ON PHOTOCELL OFF) OFF)
NEU.NEU. OPEN OPEN CLOSE CLOSE
H 120V H 120V N N 60C BLACK 60C BLACK LINELINE WHITE WHITE RED RED
2 2
L1 L1 LINELINE OPEN OPEN OPENLINELINE OPEN CLOSE CLOSE CLOSE CLOSE
3 3
1 1
TO DAWN SAFETY LIGHTS DUSKDUSK TO DAWN SAFETY LIGHTS (PHOTOCELL - PHOTOCELL (PHOTOCELL ON - ON PHOTOCELL OFF) OFF)
2 2
NEUNEU OPEN OPEN CLOSE CLOSE
LOAD LOAD
LOAD LOAD
#P69 for 7 pairs of ON/OFF trippers. #36 (120V) #66061
RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage. NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 45
ENCLOSURE TYPE
OUTPUT CONTACTS
MANUAL BY-PASS SWITCHES: Single pole, 20 Amps – one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent – will not disturb automatic settings.
ELECTROMECHANICAL CONTROLS
MANUAL CONTROLS MANUAL CONTROLS
MANUAL CONTROLS MANUAL CONTROLS
T920L
Replacement Trippers Replacement Motor Replacement Bypass Switch
ALL3 3CIRCUITS CIRCUITSARE AREINCLUDED INCLUDEDININT930L T930L ALL
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
SPECIFICATION WRITER’S GUIDE T900 SERIES – Furnish and install, where shown, a TORK Photo/Time Control of the 7 Day Calendar dial type, which shall be suitable to operate mechanicallyheld contactor(s). Photo/Time Control shall be pre-wired to a central terminal block which provides connecting terminals for Photocontrol and independent contactor control circuit(s). Time switch shall function to prevent energization of lighting for preset periods each day. Time switch dial shall permit different ON/OFF settings for each day of the week, with provision for omitting selected days. Control shall include pre-wired manual switching for each contactor circuit specified. Enclosure shall be NEMA 1 surface. Photocontrol to be remotely installed in appropriate outside location. It shall be fully temperature compensated and shall provide for time delay of at least 15 seconds to prevent false switching. Photocontrol shall operate control center to energize whenever natural lighting falls below 1.5 - 5.5 foot candles turn on. Spring driven reserve timing motor shall be provided sufficient to operate time switch controls at least 24 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. FOR DUSK-TO-DAWN LIGHTS: Control shall provide additional contactor circuit to above specifications except that it shall be responsive to Photocontrol only. Tork Model T-920L or equal. FOR PRESET ON/PRESET OFF: Control shall provide for additional contactor circuit to above specification except that it shall be responsive to time switch only. Tork Model T-930L.
TORK 46
TW SERIES
INPUT VOLTAGE: 120 or 208 - 277VAC, 60Hz, varies by model.
TYPE
VOLTAGE
CONTACT RATING
General Purpose
120/277VAC
20A
Motor
120VAC 240VAC
1HP 2HP
TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG.
CALIFORNIA Title 24
OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
ASHRAE 90.1
APPLICATIONS Heating Air conditioning Display lighting Ventilating systems Lighted signage Storefront lighting
CONTACT RATINGS
SPECIFICATIONS
DIFFERENT SCHEDULES EACH DAY MANUAL BYPASS SWITCHES RESERVE POWER STANDARD 7 DAY TIME SWITCH
POWER CONSUMPTION: 5 watts maximum.
Optional "E" cover
ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).
WIRING DIAGRAMS MANUAL CONTROLS MANUAL CONTROLS ON ON OFF ON
AUTO
ORDERING INFO FEATURES
CATALOG NO.
UPC CODE
OUTPUT CONTACTS
SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial accommodates up to 2 pairs of ON-OFF trippers per day – 7 pairs are supplied.
TW-220L
39013
120
DPDT
TW-220L-E
39021
120
DPDT
TW-222L
39014
208-277
DPDT
SKIP-A-DAY: Omit operations on any day.
TW-300L
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. MANUAL BY-PASS SWITCHES: Single pole, 20 Amps – one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent – will not disturb automatic settings.
TW-302L Replacement Trippers Replacement Motor Replacement Bypass Switch
39016
120
3PST
208-277
3PST
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
1
2
1
#36 (120V) & #46 (208-277V) #66061
3
ON
5
4
5
AUTO
6 6
NOTE: Switching contacts NOTE: are unpowered Switching contacts are unpowered
OFF
OFF AUTO
7
9
8
7
9
8
LINE LOAD LINE LINE LOAD LOAD LINE
N
H N
H
TW300L TW300L
When single line source is When source is used, single jumperline terminals used, jumper terminals 1-5-7-9 and connect all com1-5-7-9 and connect2all commons to terminals and 3. mons to terminals 2 and 3.
LOAD LINE LOAD LINE LOAD
MANUAL CONTROLS MANUAL CONTROLS ON OFF ON
1
2
1
H
3
4
OFF
TW220L TW220L
OFF AUTO
AUTO
TIME SWITCH TIME SWITCH 2 4 3
M M
ON ON
OFF AUTO
AUTO
5 5
6 6
7 7
8 8
CONTACTOR CONTROL CONTACTOR CIRCUIT 9 CONTROL CIRCUIT 9
N
H
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 47
Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1
Order #P69 for 7 pairs of ON/OFF trippers.
RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage.
ELECTROMECHANICAL CONTROLS
ENCLOSURE TYPE
M
ON
OFF
OFF AUTO
AUTO
TIME SWITCH TIME SWITCH 2 4 3
M
INPUT SUPPLY (VAC) 60Hz
39015
ON
OFF AUTO
N
CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT
COMMON OPEN COMMON CLOSE OPEN CLOSE COMMON
COMMON OPEN CLOSE OPEN
Wiring shown is for mechaniWiring shown is for mechanically-held contactors. Use cally-held contactors. CLOSE terminal onlyUse for magCLOSE terminalcontactors only for magnetically-held and netically-held contactors and to control direct loads not toexceeding control direct loads not 2000 watts. exceeding 2000 watts.
CLOSE
SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch of the 7 day type, capable of being set for different ON/OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 24 hours after power outage. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. Time switch shall provide for automatic operation with a minimum of one hour between an ON/OFF operation with minimum of four ON/OFF operations per day. ON/OFF operations shall be accomplished by removable ON/OFF trippers on the dial. Time switch contacts shall be capable of carrying a minimum 20 amperes per pole continuously at 277 volts and shall be DPDT or 3PST. Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with 1⁄2” - 3⁄4” combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking. (Specify “E” door for manual switches to be accessible when case is locked). Shall be TORK Model TW (to fit switch requirement) or equal in general purpose NEMA 1, (general purpose metal) or (Indoor/Outdoor NEMA 3) enclosure.
TORK 48
TZ SERIES
CONTACT RATINGS
SPECIFICATIONS
MANUAL BYPASS SWITCHES RESERVE POWER STANDARD ASTRONOMIC TIME SWITCH
INPUT VOLTAGE: 120 or 208 - 277VAC, 60Hz, varies by model.
TYPE
VOLTAGE
CONTACT RATING
General Purpose
120/277VAC
20A
Motor
120VAC 240VAC
1HP 2HP
TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).
CALIFORNIA Title 24
APPLICATIONS
ASHRAE 90.1
POWER CONSUMPTION: 5 watts maximum.
Schools Industrial yards Shop windows Parking lots Highway signs Bridges
ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp and for some models enclosures is Indoor/Outdoor NEMA 3 metal with suffix "O" (see page 153 for enclosure dimensions).
WIRING DIAGRAMS ASTRONOMIC LATITUDE ZONES 45° 42°
ORDERING INFO FEATURES SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/- 20 or 40 minutes from both sunset and OFF times. Available from 18° - 45° northern latitudes. SKIP-A-DAY: Omit operations on any day with a 7 spoke wheel marked with days of the week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. MANUAL BYPASS SWITCHES: Single pole, 20 Amps - one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent, will not disturb automatic settings.
CATALOG NO.
TZ-220L* TZ-220L-O*
UPC CODE
** **
INPUT SUPPLY (VAC) 60Hz
40° OUTPUT CONTACTS
120
DPDT
120
DPDT
TZ-222L*
**
208 - 277
DPDT
TZ-300L*
**
120
3PST
TZ-300L-O* TZ-302L* Replacement Motor Replacement Bypass Switch
** **
120
3PST
208 - 277
3PST
Metal Indoor NEMA 1 Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1
34°
NOTE: Switching contacts NOTE: are unpowered Switching contacts are unpowered
AUTO WASHINGTON
OREGON
NORTH DAKOTA
MONTANA
MINN
WYOMING
MAINE
WISCONSIN
SOUTH DAKOTA
IDAHO
AUTO
MICHIGAN
NH NEW YORK
NEBRASKA ILLINOIS NEVADA
UTAH
IND
COLORADO KANSAS
PENNSYLVANIA
OHIO
KENTUCKY
ARIZONA
NEW MEXICO
ARKANSAS
TENNESSEE
RHODE ISLAND CONNECTICUT
VIRGINIA
DELAWARE MARYLAND
M
2
1
3
5
4
5
6 6
7 7
9
8
LINE LOAD LINE LINE LOAD LOAD LINE LINE LOAD LOAD LINE LOAD
9
8
N
H
N
H
NORTH CAROLINA SOUTH CAROLINA
MISS ALABAMA
TEXAS
1
MASS
NEW JERSEY
WEST VIRGINIA
MISSOURI
CALIFORNIA OKLAHOMA
M
VT
IOWA
TIME SWITCH TIME 2 SWITCH 4 3
GEORGIA
LOUISIANA
30°
TZ300L TZ300L When single line
sourcesingle is used, When line jumperis terminals source used, 1, 5, 7,terminals 9 and connect jumper 1,all5,commons 7, 9 and toconnect allterminals commons2 and to 3. terminals 2 and 3.
MEXICO FLORIDA
18° HAWAII
MANUAL CONTROLS
18° PUERTO
MANUAL CONTROLS
RICO
M 1 1 H H
M
TIME SWITCH TIME 2 SWITCH 4 3 2
3
4
5 5
6 6
7 7
8 8
9 9
N N
CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT
CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT
COMMON OPEN COMMON CLOSE OPEN COMMON CLOSE
OPEN COMMON CLOSE OPEN CLOSE
TZ220L TZ220L Wiring shown is for
mechanically Wiring shown isheld for contactors. Use mechanically heldCLOSE terminal only contactors. Usefor CLOSE magnetically held terminal only for contactors and magnetically heldto control direct contactors and loads to not exceeding control direct2000 loadswatts. not exceeding 2000 watts.
#66061
*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45). **Consult factory for UPC number.
NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.
TORK 49
38°
For "L" models #36 (120V) & #46 (208-277V)
RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage.
ELECTROMECHANICAL CONTROLS
ENCLOSURE TYPE
MANUAL CONTROLS MANUAL CONTROLS
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device, and a 3-way manual switch for each circuit. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. ON operation shall occur automatically at sunset in (city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustability of 20 or 40 minutes before or after sunset and sunrise. Time switch contacts shall be capable of carrying a minimum of 20 amperes per pole continuously at 277 volts and shall be DPST (3PST). Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with 1⁄2” - 3⁄4” combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking. (Specify “E” door for manual switches to be accessible when case is locked). Time switch shall be TORK Model TZ-___ (to fit requirement).
TORK 50
DIGITAL TIME SWITCHES
FEATURES QUICK LOOK DTU40
DTWH40
E-PB
E
EW
EWZ
DG
DGM
DZS
DTS
DWZ
Page No.
55
55
57
57
59
61
63
63
65
67
69
Number of Channels
1
1
1
1 or 2
1 or 2
1 or 2
1 or 2
1
1, 2, or 4
1, 2, or 4
20 (140)
20
20
20
56
56
99
ON/OFF Set Points
7 pair (98) 7 pair (98)
DW
DZM
ELC71/72 ELC74/78/712
Page No.
69
71
73
1
Number of Channels
2
2
99
99
ON/OFF Set Points
99
99
7/365 day
7/365 day
7/365 day
LIGHTING CONTROLS
CYCLE - SIGNAL TIMER
DGU
DGUM
DGLC
DLC400
DG
DGS
DIN
75
79
79
79
81
85
85
89
1 or 2
4, 8, or 12
1
1
1 or 2
4
1 or 2
1
1 or 2
128
128
56
56
56
99
56
56
8 pair 3 pair/ch
7/365 day
7/365 day
24 Hour
7 Day
7 Day
365 Day/7 Day Scheduling
7 day
7 day
24 hour
24 hour
7 day
7 day
Automatic Daylight Savings Adjustment
Manual
Manual
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Automatic Daylight Savings Adjustment
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Leap Year
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
24
24
24
Individual Holiday Schedules
24
24
26
26
10
10
Yes
Yes
Yes
Yes
Leap Year
7/365 day 7/365 day
ENERGY/LIGHTING CONTROLS
Individual Holiday Schedules Block Holiday
9
9
Season Scheduling
Block Holiday 4
Astronomic (Sunrise/Sunset)
Yes
365 Day/7 Day Scheduling 7/365 day 7/365 day
4
Yes
Yes
Season Scheduling
4
Astronomic (Sunrise/Sunset)
Yes
7/365 day 7/365 day 7/365 day 7/365 day
24 9
9
9 4
Yes
Yes
Yes
Photosensor Input
Photosensor Input
Yes
Yes
Yes
Yes
Yes
Yes
Remote Override Input
Remote Override Input
Yes
Yes
Yes
Yes
Yes
Yes
User Defined Input
User Defined Input
Yes
Yes
Signal/Pulse Duration
Yes
Yes
Yes
Yes
Yes
Yes
Signal/Pulse Duration
Yes
Momentary for Contactors
Option
Option
Option
Yes
Yes
Momentary for Contactors
Duty Cycle
Duty Cycle
31 Day Cycle
31 Day Cycle
Yes
Yes
Yes
Manual Override
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Manual Override
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Clock Format
AM/PM
AM/PM
AM/PM
AM/PM
AM/PM
AM/PM
12/24
12/24
12/24
12/24
12/24
Clock Format
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
12/24
AM/PM
7 day Super Capacitor
7 day Super Capacitor
Power Outage Backup
Permanent
Permanent
Permanent
Schedule Retention without power
Yes
Yes
Power Outage Backup Schedule Retention without power
Rechargeable Rechargeable 4 day Super 4 day Super 4 day Super 4 day Super 7 day Super 7 day Super 7 day Super Battery Battery Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Battery
Battery
Staggered Start
Permanent Permanent Yes
Yes
Permanent Yes
Permanent Permanent Permanent Yes
Yes
Yes
Memory Module Computer Programming Software Output Contacts: Amps Resistive or General Purpose
Staggered Start
Yes
Memory Module
Yes
Computer Programming Software Output Contacts: Amps Resistive or General Purpose Contact Type: Dry Unpowered
40A
40A
30A
40A
40A
40A
20A
20A
30A/20A
30A/20A
30A
Contact Type: Dry Unpowered
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Voltage Input AC
120/208240/277
120/208240/277
120
120-277
120-277
120-277
120-277
120-277
120/208240/277
120/208240/277
120/208240/277
Low Voltage Input (select models) TORK 53
12VDC 24VAC
Voltage Input AC Low Voltage Input (select models)
7 day Super 7 day Super 7 day Super Capacitor Capacitor Capacitor Permanent Permanent Yes
Yes
2 day Capacitor 7 day Super 7 day Super 7 day Super 1 year battery Capacitor Capacitor Capacitor
Capacitor
Battery
Permanent
Permanent
Yes
Yes
Yes
Yes
6 month battery
7 day Super 7 day Super Capacitor Capacitor
Permanent Permanent Permanent Yes
Yes
Yes
Permanent
Yes
Yes
8 year battery Battery
Yes
Yes
Yes
Yes
30A
30A
20A
20A
20A
20A
20A
30A
20A
20A
16A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
24/120/208 240/ 277
120-277
120-277
120-277
120/208240/277
120-277
120-277
120
12VDC 24VAC
24VAC
120/208- 120/208- 120/208-240/ 240/277 240/277 277
24VAC All Models
TORK 54
DT SERIES
NEW!
AUTOMATIC VOLTAGE DETECTION 24 HOUR OR 7 DAY HOUR TIME SWITCH
MORE WIRING SPACE! NEW!
INPUT VOLTAGE: 120/208-240/277 VAC, 50/60 Hz (auto detection). DTWH40 is 120/240VAC (auto detection).
TYPE
VOLTAGE
Resistive
TERMINAL RANGE: #8 - #18AWG. OPERATING TEMPERATURE: -31°F to 116°F (-35°C to +47°C).
APPLICATIONS DTU40 Pumps, motors, fans Signs and lighting Water heaters Heating and air conditioning
CONTACT RATINGS
SPECIFICATIONS
POWER CONSUMPTION: 6VA Max. ENCLOSURE: DTU40 polycarbonate Indoor/ Outdoor NEMA 3R. DTWH40 polycarbonate indoor NEMA 1 enclosure with clear cover. Both with lockable hasp (see page 153 for enclosure dimensions).
DTU40
DTWH40
DTWH40 Water Heaters This timer turns OFF when rates are high and turns OFF when no one is home.
SAVE ENERGY!
120-277VAC
40A
30A
Inductive
120-277VAC
30A
15A
Ballast
120VAC 277VAC
30A 20A
10A 10A
Tungsten
120VAC
15A
120VAC 240VAC 120VAC 240VAC
1HP/30FLA/90LRA 2HP/20FLA/60LRA 720VA 720VA
Resistive
28VDC
20A
Max above 104°
120-277VAC
30A
Pilot duty
1⁄4HP/12FLA/30LRA 1⁄2HP/12FLA/33LRA
290VA 260VA
Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application TIMER SUPPLY N
NC
CATALOG NO.
UPC CODE
TIMER SUPPLY (VAC) 60Hz
NO. OF CHANNELS
DRY CONTACTS (UNPOWERED)
L
N
DTU40
24004
120/208-240/277
1
DPDT
DTWH40
24005
120/240
1
DPDT
H
NC
N
NO
C
LOAD L
N
NC
NO
C
WIRING DIAGRAMS L1
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
C
N
L
Typical Wiring Diagram, 208-240 VAC Application TIMER SUPPLY
DAYLIGHT SAVING: Manual button push for one hour adjustment.
NO LOAD
ORDERING INFO
SCHEDULING: 7 ON & OFF pairs of set points for individual programs on each day of the week. Minimum setting is 1 minute.
NC
DTU40
H
FEATURES
NO
Motor
Avoid utility peak rates Turn off when not needed
RATING
NC
NO
C
LOAD
L2
L1
L2
DTWH40
DTU40
Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application
EXTERNAL MANUAL OVERRIDE: DTWH40 only on clear door. Override without opening case.
TIMER SUPPLY H
N
TIMER SUPPLY NC
NO
C
NC
LOAD
RANDOM MODE: Varies ON and OFF times to create "lived-in" look when away.
L
CLOCK FORMAT: AM/PM.
Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application
N
N
NO
C
H
L
N
L
TIMER SUPPLY H
N
NC
NO
C
L
N
N
L2
NO
C
LOAD L
N
L
Typical Wiring Diagram, 208-240 VAC Application TIMER SUPPLY
NC
NO
C
NC
NO
C
H
N
NC
NO
C
LOAD L1
NC
LOAD
Typical Wiring 208-240 VAC Application Typical Diagram, Wiring Diagram, 240VAC
POWER OUTAGE BACKUP: Battery retains time and schedule.
N
LOAD
L1
NC
NO
C
LOAD L2
L1
L2
L1
L2
DTWH40 Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application
DIGITAL CONTROLS TORK 55
TIMER SUPPLY H
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
N
NC
NO
C
LOAD L
N
N
NC
NO
C
LOAD L
N
L
TORK 56
E & E-PB SERIES
CONTACT RATINGS
SPECIFICATIONS
BACK-UP WITHOUT BATTERY, ECO FRIENDLY!
MULTIPURPOSE CONTROLS 1 OR 2 CHANNEL 24 HOUR TIME SWITCH
INPUT VOLTAGE: E SERIES 120 - 277VAC, 50/60Hz (automatic detection). E-PB 120VAC, 50/60Hz.
APPLICATIONS
TERMINAL RANGE: #8 - #16AWG.
E101B
Signs Air conditioning Lighting Sump pumps Ventilating fans
OPERATING TEMPERATURE: -40° to +149°F (-40° to +65°C).
1
4CONSUMPTION: 6VA Max. 3 POWER
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R is standard with lockable hasp (see page 153 for L N N 120/277VAC enclosure dimensions).
2A
120VAC
5A
720VA
720VA
720VA
120-277VAC
470VA
1HP
1HP 11⁄2HP 2HP
1HP 11⁄2HP 2HP
120VAC 240VAC
1HP 2HP
30A
30A
28VDC
20A
30A
Inductive
120-277VAC
40A
30A
30A
Ballast
120VAC 208-277VAC
30A 20A
30A 20A
Tungsten
120VAC
15A
120-277VAC
Pilot Duty
E101B
3
2
120VAC TIMER 5 SUPPLY LOAD 208VAC 240-277VAC
Motor4
LOAD
LOAD
L
15A
30A
SPDT
1
10A 10A
30A 12A 30A 12A 20A 6A
40A
TIMER SUPPLY
Resistive N
N
N
1 28VDC
SPST 11 2HP
⁄
2HP
2
3
120/277VAC
E101PB VOLTAGE RATING NO
120/240VAC 277VAC 120/240VAC 277VAC 120VAC 277VAC
120-277VAC
SPST
2
E120B RATING NO NC
VOLTAGE
General Purpose
E120B
TIMER SUPPLY
E101B, E103B, E201B RATING NO
TYPE
TIMING ACCURACY: Line Frequency.
4
30A
E120
TIME SUPP 1
LOAD L
N
N
L
120/277VAC
WIRING DIAGRAMS
E103B
DPST
TIMER SUPPLY
E101B 1
FEATURES SCHEDULING: 20 ON/OFF set points repeat each day. Minimum setting 1 minute.
E101B
UPC CODE
82401
INPUT SUPPLY (VAC) 50/60Hz
120-277
NO. OF CHANNELS
OUTPUT DRY CONTACTS
1
E103B
82411
120-277
1
82406
120-277
1
LEAP YEAR: Automatic Compensation.
E201B
82466
120-277
2
E101PB
82401
120-277
L
1N
N
2
3
L
TIMER SUPPLY
L
1
4
N
E101B
2
3
4
N 5
N
3
1 2 TIMER SUPPLY
SPST LOAD
1
N
120/277VAC
2 N
L
6
TIMER SUPPLY 1 LOAD
E101PB DPST
SPDT TIMER SUPPLY 1
3
2
N
L
2
LOAD
4
3
4
LOAD
5
TIMER SUPPLY
5
6
1
2
L
N
4 N
5
N
3
4
5
120/277VAC
N
2
3
4
5
6
PULSE OFF E201B
E201B ONLY: UNIT MUST BE CONFIGURED FOR TIMER MOMENTARY OPTION.
2
L
N
N
3 TIMER SUPPLY LOAD 1
3
CH 1 SP
4
3
2
LOAD
N
120VAC N
6 TIMER SUPPLY
PULSE ON
1
L
E201B
L
L2
208 OR 240VAC
CH 1 SPST
LOAD
LOAD
1
2
L
N
MOMENTA C
3
4
CH 2 SPST
SUPPLY
N
L
2
SPST
120/277VAC
LOAD
N
N
L
DPST
TIMER SUPPLY
MOMENTARY CONFIGURATION CH 1
L1
6
N
120/277VAC
1 LOAD
N
L N N N 120/277VAC
4DPST 5 LOAD
LOAD
3
L
1
120/277VAC L
N
N
TIMER SUPPLY
LOAD
POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup.
5
6
E103B
4
3
LOAD
4
120/277VAC
TIMER SUPPLY LOAD
L2
3
2
L
N
SPDT L1
208 OR 240VAC
SPST
1
2
E120B E103B
LOAD
E120B
SPST SPDT
TIMER SUPPLY
1
1
DPST
CH 2 SPST
LOAD
DPST
TIMER SUPPLY
CH 1 SPST
LOAD
120/277VAC
SPST
L
CLOCK FORMAT: AM/PM.
4
5
6
N
L
N
120/277VAC LOAD
PULSE O
E201B O BE CON MOMEN
120/277VAC
120/277VAC
DPST
TIMER SUPPLY
1
E201B
1
2
4
3
5
6
LOAD L
LOAD N
N
N
L
120/277VAC DPST
TIMER SUPPLY
1
2
3
4
5
6
L2
208 OR 240VAC
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
LOAD
2
3
4
5
6
CH 1 CH 2 SPECIFICATION SPST SPST WRITER’S
MOMENTARY CONFIGURATION
TIMER GUIDE CH 1 SUPPLY TIMER E100B only – 1. Furnish and install a TORK digital time switch with (40 Amp SPST contacts, model E101B,E201B) (40 Amp DPST contacts, model E103B) (30 Amp SPDT SUPPLY L1 L2 contacts, model E120B). 2. Unit shall be capable of 20 set points. 3. Unit shall repeat the same schedule each day. 4. (Model E201B ONLY) Unit shall be capable of being LOAD 208 OR 240VAC 1 2 3 4 5 6 4 maintained 5 1 2 6 a 1 channel momentary 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. Unit shall program in AM/PM a32 channel or LOAD LOAD format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFFL either to thePULSE nextON scheduled event or permanently. 11. Unit shall have a NEMA 3R Indoor/Outdoor PULSE OFF N N L 12. Unit Nshall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model E101B (E103B) (E120B) L N plastic enclosure. 120/277VAC E201B ONLY: UNIT MUST 120/277VAC BE CONFIGURED FOR MOMENTARY OPTION. (E201B).
TIMER SUPPLY L1
DPST
TIMER SUPPLY
E103B
MOMENTARY OPTION: For mechanically held contractors: Model E201B only. Configure with simple jumper change for single-channel momentary operation.
TORK 57
TIMER SUPPLY
120/277VAC
E120B
DIGITAL CONTROLS
E201B SPST 6
5
LOAD
DAYLIGHT SAVING: Automatic adjustment (can be omitted). MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
4
3
2
ORDERING INFO CATALOG NO.
120/2
1
2
L
N
MOMENTARY CONFIGURATION CH 1
3
4
PULSE ON
5
6
PULSE OFF
TORK 58
EW SERIES
AUTOMATIC DST - SAVES TIME CHANGES TWICE A YEAR
MULTIPURPOSE CONTROL 1 OR 2 CHANNEL 7 DAY TIME SWITCH
SPECIFICATIONS
CONTACT RATINGS
TIMING ACCURACY: Line Frequency.
TYPE
INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). energy
APPLICATIONS
ASHRAE 90.1
Outdoor signs Lighting security Heating and air conditioning
40A
120-277 VAC
30A
30A
Inductive
120-277VAC
40A
120-277 VAC
30A
30A
Ballast
120VAC 208-277VAC
30A 20A
120VAC 208-277VAC
30A 20A
10A 10A
Tungsten
120VAC
15A
120VAC
15A
2A
Pilot Duty
120-277VAC
720VA
120-277 VAC
720VA
720VA
Motor
120VAC 208VAC 240-277VAC
SPST 1HP TIMER 120VAC 11⁄2HPSUPPLY 208VAC 2HP 240-277VAC
1HP 11⁄2HP 2HP
1HP 11⁄2HP 2HP
Resistive
28VDC
30A
30A
POWER CONSUMPTION: 6VA Max. ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R. EW101B Suffix -C plastic clear cover Indoor/Outdoor NEMAEW120B TIMER 3R. Suffix SPST -Y metal Indoor enclosure NEMA 1. All TIMER SUPPLY with lockable hasp (see page 153 for enclosure SUPPLY dimensions). 1 2 3 4 1
2
L
N
SPDT
3
LOAD
4
LOAD
5
EW101B
1
2
30A
N
N
WIRING DIAGRAMS
120/277VAC
ORDERING INFO FEATURES SCHEDULING: 20 ON & OFF set points for individual programs for each day of the week. Minimum setting is 1 minute. DAYLIGHT SAVING: Automatic (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup.
1
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 50/60Hz
NO. OF CHANNELS
EW101B
82431
120-277
1
SPST
EW103B
82441
120-277
1
DPST
EW120B
82436
120-277
1
SPDT
EW201B
82467
120-277
2
SPST
EW103B-C
82253
120-277
1
DPST
82255
120-277
1
L
EW120B-Y EW201B-Y
82437 82261 82299
120-277 120-277 120-277
1 1 2
EW101B SPST
TIMER SUPPLY
1
2
1
3
N
3
N
120/277VAC
N L
1
CH 2 SPST
2
120/277VAC
3
4 LOAD PULSE OFF
LOAD
N
N
CH 1
1
2
3
4
5
1
2
N
120/277VAC
PULSE ON
L N
N
N
DPST momentary configuration
3
EW103B 4 5 TIMER SUPPLY
6
1
2
DPST
1
4
3
LOAD
CH 1
TIMER SUPPLY
5
2
3
N
LOAD N
L
N
L
4
5
6
6
120/277VAC N
PULSE ON
PULSE OFF
EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION
120/277VAC
N
DPST
TIMER SUPPLY
CH 1
3
1
2
L1
L2
3
4
5
6
DPST
TIMER SUPPLY 4
5
6
LOAD SPECIFICATION 1WRITER’S GUIDE 4 3 5 6 2 208 OR 240VAC EW SERIES – 1. Furnish and installON a TORKPULSE digital OFF time switch with (40 Amp SPST contacts, model EW101B, EW210B) (40 Amp DPST contacts, model EW103B) (30 Amp PULSE L N LOAD LOAD SPDT contacts, model EW120B). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule each day of the week. 4. (Model EW201B ONLY) 120/277VAC EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. L N N L N Unit shall program in AM/PM format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super 120/277VAC capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFF either to the next scheduled event or permanently. 11. Unit shall have DPST TIMER a NEMA 3R Indoor/OutdoorSUPPLY plastic enclosure. 12. Unit shall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model EW101B (EW103B) (EW120B) (EW201B).
1
2
L1
L2
3
4
5
6
6
208 OR 240VAC L
N
L
EW103B
TIMER SUPPLY
CH 2 SPST
5
LOAD
momentary configuration
CH 1 SPST
N
L2
120/277VAC
EW201B
6
LOAD
208 OR 240VAC
5
EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION
L
5 4
6
PULSE ON
CH 2 SPST
LOAD
TIMER SUPPLY
SPST
TIMER 4 5 SUPPLY 2
4
LOAD
120/277VAC
L1
momentary configuration
TORK 59
2
3
2
120/277VAC
CH 1 SPDT
1 L
TIMER SUPPLY
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
3
CH 1
4
N
MOMENTARY OPTION: For mechanically held contractors: Model EW201B only. Configure with simple jumper change for single-channel momentary operation.
DIGITAL CONTROLS
L
N
EW120B EW201B
TIMER SUPPLY
SPDT SPST
2 1
PULSE OFF
EW201B ONLY: UNIT MUST BE
TIM SU 1
L
CH 1 SPST
LOAD
momentary configuration
DPST SPDT
1
EW
120
SUPPLY
4
N
N
EW201B
TIMER TIMER SUPPLY
120/277VAC
L
EW120B-C
3
N
SPDT DPST
LOAD
LOAD
EW103B-Y
2
4
120/277VAC
EW120B EW103B
SPST CH 2 SPST
CH 1 TIMER SPST SUPPLY
L
N
120/277VAC
EW101B
EW201B
OUTPUT DRY CONTACTS
N
3
28LOAD VDC
LOAD L
RATING NO NC
120-277VAC
OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C).
CALIFORNIA Title 24
EW120B VOLTAGE
General Purpose
TERMINAL RANGE: #8 - #16AWG. responsible
EW101B, EW103B, EW201B RATING VOLTAGE NO
LOAD
TORK 60
EWZ SERIES
PREFERRED FOR OUTDOOR LIGHTING
MULTIPURPOSE CONTROL 1 OR 2 CHANNEL, ASTRONOMIC 7 DAY TIME SWITCH
SPECIFICATIONS
CONTACT RATINGS
TIMING ACCURACY: Line Frequency.
TYPE
INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). energy
APPLICATIONS
ASHRAE 90.1
Outdoor signs Lighting security Heating and air conditioning
40A
120-277 VAC
30A
30A
Inductive
120-277VAC
40A
120-277 VAC
30A
30A
Ballast
120VAC 208-277VAC
30A 20A
120VAC 208-277VAC
30A 20A
10A 10A
POWER CONSUMPTION: 6VA Max.
Tungsten
120VAC
15A
120VAC
15A
2A
ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R
Pilot Duty
120-277VAC
720VA
120-277 VAC
720VA
720VA
Motor
120VAC 208VAC 240-277VAC
1HPTIMER SUPPLY 11⁄2HP 2HP
SPST 120VAC 208VAC 240-277VAC
1HP 11⁄2HP 2HP
1HP 11⁄2HP 2HP
Resistive
28VDC
28 VDC
30A
30A
is standard with lockable hasp (see page 153 forEWZ120 EWZ101 SPST enclosure dimensions).
Suffix -MB without enclosure TIMER and includes mounting bracket. SUPPLY
SPDT
TIMER SUPPLY
1
2
3
4
1
2
3
LOAD
4
LOAD
5
LOAD L
N
N
120/277VAC
L
WIRING DIAGRAMS120/277VAC
SCHEDULING: 20 ON & OFF set points for individual programs for each day of the week. Minimum setting is 1 minute. ASTRONOMIC: Adjustable 10° - 60° Northern or Southern latitudes. Can be individually offset +/- 1-240 minutes from both sunset and sunrise times. DAYLIGHT SAVING: Automatic (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 50/60Hz
1
NO. OF CHANNELS
82470
120-277
1
SPST
EWZ103
82473
120-277
1
DPST
EWZ120
82471
120-277
1
SPDT
EWZ201
82472
120-277
2
SPST
120-277
1
82269
120-277
1
DPST
EWZ120-MB
82275
120-277
1
SPDT
EWZ201-MB
82281
120-277
2
SPST
TIMER SUPPLY
2
1
3
SPST
EWZ103-MB
SPST
2
1 L
N
CH 2 SPST
POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup. MOMENTARY OPTION: For mechanically held contactors: Model EWZ201 only. Configure with simple jumper change for single-channel momentary operation. momentary configuration CH 1
TIMER SUPPLY
TORK 61
3
4 LOAD PULSE OFF
1
N
L1
5
2
3
4
5
2
3
TIMER SUPPLY
L
N
PULSE ON
L N
CH 2 SPST
LOAD
N
N
DPST
EWZ103 4
5
6
4
5
L2
1
2
4
3
LOAD
CH 1
TIMER SUPPLY
DPST
5
1
2
LOAD L
N
3
N
N
L
4
5
6
6
120/277VAC L
N
N
PULSE ON
PULSE OFF
EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION
120/277VAC DPST
TIMER SUPPLY
1
2
3
4
5
6
6
L1 L2 4 3 5 6 1 2 SPECIFICATION WRITER’S GUIDE LOAD 208 OR 240VAC EWZ SERIES – 1. Furnish and install TORK digital time switch with (40 AMP contacts, models EWZ101, EWZ201) (40 Amp DPST contacts, model EWZ103) (30 AMP PULSE ON PULSE OFF LOAD LOAD L N contacts, model EWZ120). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule for each day of the week. 4. Unit shall be have 120/277VAC EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR1°MOMENTARY OPTION astronomic option adjustable from 60° northern or southern latitudes. 5. Unit shall be have astronomic option with offset up to 4 hours and 59 minutes, before or L N N L N after sunrise. 6. (Model EWZ201 ONLY) Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 7. Unit shall have automatic Daylight Savings 120/277VAC Time and Leap Year compensation. 8. Unit shall program in AM/PM format. 9. Display shall be of LCD type. 10. Unit shall have permanent schedule retention. 11. Unit DPST TIMER real time clock shall beSUPPLY retained by capacitor for 100 hours in a power failure. 12. Unit shall be capable of manual override ON or OFF either in the next scheduled event or permanently. 13. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 14. Unit shall have Load Status indication. 15. Unit shall have Power Failure indication. 16. To order1specify 4 3 Model EWZ101 5 (EWZ103) 6 (EWZ120) (EWZ201). 2 TORK
6 L2
PULSE OFF
EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION
TI SU 1
L
5
LOAD
DPST
208 OR 240VAC 120/277VAC
3
208 OR 240VAC
CH 1 EWZ103
L1
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
LOAD
N
TIMER SUPPLY
1
2
6
LOAD
TIMER SUPPLY
momentary configuration
CH 1 SPST
N
5 4
EW
120
CH 1 SPST
6
2
N
momentary configuration
CH 2 SPST
SPST
120/277VAC
EWZ201
4
LOAD LOAD
N
1
EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION
L
120/277VAC
3
TIMER SUPPLY
SPDT CH 1
PULSE ON
N
120/277VAC N
CLOCK FORMAT: AM/PM.
DIGITAL CONTROLS
3 2
L N 120/277VAC
EWZ120 TIMER SUPPLY 4 5
N
EWZ201
120/277VAC
EWZ201 3
L
4
LOAD
DPST SPDT
CH 1
4 LOAD
L
2 1
L
N
momentary configuration
TIMER SUPPLY
3
SUPPLY
1
4
N
2
120/277VAC
TIMER TIMER SUPPLY
120/277VAC
EWZ101
1
30A
N
LOAD L
1
82263
3
OUTPUT DRY CONTACTS
EWZ101
EWZ101-MB
2
EWZ101
EWZ120 EWZ103 SPST CH 2 SPST
CH 1 TIMER SPST SUPPLY
ORDERING INFO
N
N
EWZ101
EWZ201
FEATURES
RATING NO NC
120-277VAC
OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C).
CALIFORNIA Title 24
EWZ120 VOLTAGE
General Purpose
TERMINAL RANGE: #8 - #16AWG.
responsible
EWZ101,EWZ103, EWZ201 RATING VOLTAGE NO
LOAD
TORK 62
DG100 SERIES MULTIPURPOSE CONTROLS 1 OR 2 CHANNEL 365/7 DAY TIME SWITCH
HOLIDAY PROGRAMMING FOR MORE SAVINGS!
NEW!
SPECIFICATIONS
CONTACT RATINGS
TIMING ACCURACY: Line Frequency.
TYPE
VOLTAGE
NO
NC
Resistive
24-277VAC
20A
10A
Ballast
120 VAC 277 VAC
20A
10A
Tungsten
120VAC
15A
INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). TERMINAL RANGE: #12 - #18AWG.
APPLICATIONS
OPERATING TEMPERATURE: -31° to +131°F (-35° to +55°C).
CALIFORNIA Title 24
Pilot Duty
POWER CONSUMPTION: 6VA Max.
ASHRAE 90.1
Indoor/Outdoor lighting HVAC equipment School warning and other Traffic lights Water heaters in offices, churches and factories
Motor
ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R. Suffix -Y metal indoor enclosure NEMA 1. All with lockable hasp (see page 153 for enclosure
Resistive
120VAC 240VAC 120VAC 240VAC 28VDC
RATING
1HP 2HP
290VA 360VA 1⁄4HP 1⁄2HP
20A
10A
720VA
dimensions).
WIRING DIAGRAMS DGM100A
DG200A
ORDERING INFO CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 50/60Hz
NO. OF CHANNELS
OUTPUT CONTACTS
SCHEDULING: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute.
DG100A
82201
120-277VAC
1
DPDT
DG200A
82209
120-277VAC
2
SPDT
MOMENTARY CONTACT: DGM100A has 2 second contact closures for ON & OFF control of mechanically held contactors or latching relays.
DGM100A
82210
120-277VAC
1
DGM100A-Y
82222
120-277VAC
1
SPDT Momentary SPDT Momentary
FEATURES
BLOCK HOLIDAY: 9 holiday blocks can be set for individual days or for duration of any number of days.
DG100A
DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or 24 Hour format.
SPECIFICATION WRITER’S GUIDE DG100/200A SERIES – 1. Furnish and install, where noted, a 1 (2) channel 7-day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast loads at 277VAC. 4. Controller shall be capable fo 56 set points; separate scheduling for each day of the week with one minute resolution. 5. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of days. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON or OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA Type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model DG100A (DG200A). 13. To order momentary contact closure for latching contactor control specify DGM100A.
POWER OUTAGE BACKUP: Permanent schedule retention is provided. Supercapacitor provides 7 days of real time back up.
DIGITAL CONTROLS TORK 63
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 64
DZM200B
DZS SERIES
REMOVABLE MEMORY MODULE FOR COMPUTER PROGRAMMING!
MULTIPURPOSE CONTROLS 1, 2 OR 4 CHANNEL 365 / 7 DAY ADVANCED TIME SWITCH
SPECIFICATIONS N
GND NO
UPPER BOARD
TIMER SUPPLY
C
ON
L
energy
APPLICATIONS
CALIFORNIA Title 24
HVAC equipment Horns and bells Interior lighting Electric motors Outdoor lighting and signs
N
PULSE ON
208-240V
INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz. 277V
N
SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart.
NO. OF CHANNELS
DRY CONTACTS (UNPOWERED)
DZS100BP
82182
120/208-240/277
1
DPDT
DZS200BP
ASTRONOMIC: Adjustable 10˚ - 60˚ Northern or Southern latitudes can be individually offset +/-1 to 240 minutes from both sunset and sunrise times.
DZS400BP USB-MMP
82183 82184
120/208-240/277 120/208-240/277
2
120
4 Memory Module Programmer
82196
SPDT
82215
120/208-240/277
1
DPDT
HOLIDAYS: 1 to 24 individual dates.
DZS200BP-0
82227
120/208-240/277
2
SPDT
SIGNAL/PULSE DURATION: 2 different settings per channel: 1-99 seconds.
DZS200BP-12
82228
12VDC
2
SPDT
DZS200BP-24
82229
24VAC
2
SPDT
DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation.
82230
120/208-240/277
4
SPDT
NC
24-277VAC
30A
30A
24-277VAC
20A
Ballast
120VAC 277VAC
30A 20A
10A 10A
120-277VAC
13A
Tungsten
120-277VAC
15A
2A
NO C
NC
L
L LOAD
N
277V
GND NO
Motor Load
C
NC
NO
C
C
N
120 208-240
120-277VAC
Resistive
28VDC120V
N
720VA
120 208-240277
30A
L
ON
OFF
C
12-277VAC
30A
1HP
ON
PULSE OFF
OFF
720VA 720VA
PULSE ON
PULSE OFF
N
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
1HP
L
PULSE ON
208-240V
8A CH 2
120-277VAC
720VA
20A
N
MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS
LOAD NO NC N
277
CH 1 SPDT L
208-240V
C
TIMER SUPPLY
Pilot Duty
120VAC CH 1
1HP 2HP
277V
L
LOADNC NO
1HP 2HP
208-277VAC
NC
CH 2 SPDT L
WIRING DIAGRAMS AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
CH 4 SPDT
CH 1 SPDT
C
120VAC DZM200B
N
120V
CH 2 SPDT
L LOAD
277V
LOAD
N
NO C
TIMER SUPPLY
LOWER BOARD
N
NC
NO C
NC
DPDT N
120
208-240 277
L
120V
C
208-240V SUPPLY AC LINE INPUT TIMER SELECT PROPER TERMINALS 277V AND APPLY ONLY ONE VOLTAGE
DZS100BP
120
L
LOAD N
NO NC
C
CH 3 SPDT
LOAD N
NO NC
208-240 277
UPPER BOARD
120V
L
208-240V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
L LOAD
277V
LOAD
N
CH 1 SPDT
C
TIMER SUPPLY
DZS200BP
120 208-240
C
C
NO NC
TIMER SUPPLY
LOAD
277V
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. In signal mode, activates pulse.
LOAD
N
N
NC
N
NO C
CH 2 SPDT
NC
NO C
NC
LOWER BOARD 120
208-240 277
L
120V
L
C
L
CH 1 SPDT
N
L
NO
LOAD
N
277
208-240V
NC
L
CH 2 SPDT
NO NC
CH 4 SPDT
LOAD
120V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
GND NO
N
DZS400BP
N
DZS400BP-0
General Purpose
PULSE OFF
CH 2 SPDT
N
LOAD
UPPER BOARD
Includes software
DZS100BP-0
N
CH 3 SPDT
N
SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year.
DZS400BP RATING VOLTAGE NO NC
208-240 277
208-240V
N
SPDT
PULSE ON
NO C
TIMER SUPPLY
TIMER SUPPLY (VAC) 50/60Hz
DZS100BP, DZS200BP RATING VOLTAGE NO NC
TYPE
MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS
ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for enclosure dimensions). DZS400BP DZS200BP
UPC CODE
CONTACT RATINGS
LOAD
120V
®
CATALOG NO.
NC
L
CH 1 SPDT
POWER CONSUMPTION: 5VA Max: DZS100/200BP. 6VA Max: DZS400BP.
FEATURES
OFF
LOWER BOARD
OPERATING TEMPERATURE: -40° to +158°F (-40° to 70°C).
ORDERING INFO
C
ON
PULSE OFF
N
TIMER SUPPLY
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
ASHRAE 90.1
NO
C
LOADL
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
responsible
NC
L
120 208-240277
120V DZS400BP TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #14-#16AWG for line input. #12-#16AWG load outputs.
C
OFF
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
LOAD
208-240V
N
277V
L LOAD N
DPDT
TIMER SUPPLY
DZS100BP
CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent schedule retention with memory module. Supercapacitor provides 7 days of real time backup.
C
NO NC
C
NO NC
SPECIFICATION WRITER’S GUIDE CH 1 CH 2 L DZS SERIES – 1. Furnish and install, where noted, a 4L (2) (1)LOAD channel digital time switch with portable Memory Module on front panel.SPDT 2. MemorySPDT Module shall be LOAD capable of being programmed at any one location and inserted into DZS100BP, 200BP, 400BP Series (with memory module socket) in any other remote location. N N C NO C NO NC 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of NC Memory Modules or DZS200BP individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in L one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day ofLOAD theL week. LOAD 9. Controller shall N N have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall haveDPDT Permanent Schedule Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of manual override ON or OFF to the next Scheduled event using 1 button for each channel. 16. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 17. Controller shall C NO NC beC capable NO NCof having 2 different pulse durations 1-99 seconds, user settable and assignable to each channel. DZS100BP 18. Controller shall be capable of having astronomic on one (or all) channels with 1-240 minutes, plus or minus offset from Sunrise or Sunset. 19. Controller shall be capable of being configured to copy to multiple memory modules. 20. To order L L specify TORK Model DZS100BP (DZS200BP) (DZS400BP). LOAD LOAD N
120
208-240 277
120V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
208-240V
277V
TIMER SUPPLY
MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZS series unit.
N
COPY FEATURE: Unit can be configured to copy program schedule to multiple memory modules. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature.
TORK 65
277
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
208-240V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
277V
TIMER SUPPLY
N
120
208-240 277
120V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
DIGITAL CONTROLS
120 208-240
120V
208-240V
277V
N
N
TORK 66
L
DTS SERIES
MAINTAINED AND SIGNAL TIMING
MULTIPURPOSE CONTROLS 1, 2 OR 4 CHANNEL 365 / 7 DAY ADVANCE TIME SWITCH
DTS400B SPECIFICATIONS
Indoor and outdoor lighting Heating and air conditioning Security systems Horns and bells Low voltage lighting Misting and spraying Roof cooling Clock correction systems Process functions
CH 2 SPDT
NO C
TIMER SUPPLY
N
120
NC
LOAD
POWER CONSUMPTION: 6VA Max.
UPPER
GND NO
ENCLOSURE: Noryl® Indoor/Outdoor NEMABOARD 3R with lockable hasp (see page 153 for enclosure dimensions).
CH 1 SPDT
NO
L
DTS400B
N
120
13A
15A
2A
120VAC
8A
120-277VAC
Pilot Duty
120-277VAC
Motor Load
120VAC 208-277VAC
1HP 2HP
1HP 2HP
28VDC
30A
30A
C
NC
Resistive
720VA 720VA
12-277VAC
720VA 720VA
120-277VAC
1HP
1HP
L
N
NO NC
C
NO NC
CH 1 SPDT
WIRING DIAGRAMS
120-277VAC
20A
LOAD
N
C
TIMER SUPPLY
DTS200B
10A 10A
Tungsten
CH 2 SPDT
LOAD
30A 20A
120VAC 277VAC
CH 4 SPDT
NC
20A
Ballast
LOAD
C
24-277VAC
30A
N
CH 3 SPDT
30A
24-277VAC
L
N
277V
RATING NO NC
General NC Purpose
NO C
L
208-240V
DTS400B VOLTAGE
VOLTAGE
208-240 277
120V
DTS100B, DTS200B RATING NO NC
TYPE
TIMING ACCURACY: Line Frequency.
OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C).
ASHRAE 90.1
CONTACT RATINGS
N CH 1 SPDT
TERMINAL RANGE: AC LINE INPUT #14 - #16AWG for lineSELECT input. PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE #12 - #16AWG load outputs.
CALIFORNIA Title 24
LOAD
N
INPUT VOLTAGE: 120/208-277VAC, LOWER 50/60Hz. BOARD
APPLICATIONS
L
LOAD
CH 2 SPDT
208-240 277
120V
208-240V TIMER SUPPLY
AC LINE INPUT SELECT PROPER TERMINALS LOWER AND APPLY ONLY ONE VOLTAGE
L
NO C
BOARD
N
120
ORDERING INFO FEATURES SCHEDULING: 99 ON/OFF set points allow individual programs for each day of the week at a minimum 1 minute apart. SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year.
CATALOG NO.
UPC CODE
TIMER SUPPLY (VAC) 50/60Hz
DTS100B NO. OF CHANNELS
DRY CONTACTS (UNPOWERED)
DTS100B
82185
120/208-240/277
1
DPDT
DTS200B
82186
120/208-240/277
2
SPDT
DTS400B
82187
120/208-240/277
4
SPDT
LOAD
DPDT L LOAD
C
NC
L LOAD
N
277V TIMER SUPPLY
120
NO C N
208-240 277
208-240V
N
NC
N
120V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
L
LOAD
277V
CH 3 SPDT
N
NO NC
C
NO NC
UPPER BOARD
208-240 277
120V
C
TIMER SUPPLY
N
CH 1 SPDT
CH 2 SPDT
NO NC
C
120
NO
C
DTS400B
LOAD
N
N CH 1 SPDT
NO NC
CH 2 SPDT
NO C
TIMER SUPPLY
NC
L
LOAD
N
208-240 277
120
NC
NO C
NC
208-240 277
L
120V
208-240V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
L
L LOAD
277V
LOAD
N
N
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
L
LOAD
208-240V
LOAD
N
277V
N
DPDT
N
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. In signal mode, activates pulse.
C
TIMER SUPPLY
DTS100B
LEAP YEAR: Automatic Compensation.
120
NO NC
C
NO NC
208-240 277
CH 1 SPDT
120V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
208-240V
L
L LOAD
CH 2 SPDT
LOAD
N N SPECIFICATION WRITER’S GUIDE C NO NC C NO NC DTS SERIES – 1. Furnish and install, where noted, a 4 (2) (1) channel digital time switch.DTS200B 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each L day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasonsACofLINEunlimited duration. 7. Different dailyL schedules shall be INPUT LOAD LOAD SELECT PROPER TERMINALS programmable within each season. 8. Controller shall have Daylight Saving or Standard time. 9.APPLY Controller have automatic Leap Year Ncorrection. 10. Controller shall AND ONLY ONEshall VOLTAGE N have Permanent Schedule Retention. 11. Controller shall have 7 day backup for real time with built in super capacitor. 12. Controller shall be capable of manual override DPDT ON to activate pulse #1 duration. 13. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 14. Controller shall be capable of having two different pulse durations 1-99 seconds, user settable and assignable to each channel. 15. To order specify TORK Model DTS100B (200B) (400B). 277V
TIMER SUPPLY
N
CLOCK FORMAT: AM/PM or Military time.
120
208-240 277
120V
208-240V
POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time back up.
277V
C
TIMER SUPPLY
DTS100B N
TORK 67
NC
L
LOAD
N
120V
DAYLIGHT SAVING: Automatic adjustment (can be omitted).
DIGITAL CONTROLS
C
LOWER BOARD N
SIGNAL/PULSE DURATION: 2 different settings per channel: each 1-99 seconds.
GND NO
L LOAD
277V
DTS200B
HOLIDAYS: 1 to 24 individual dates.
L
208-240V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
CH 4 SPDT
120
NO NC
C
NO NC
208-240 277
120V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
208-240V 277V
L
L LOAD N
LOAD N
TORK 68
DW SERIES
SPECIFICATION FAVORITE!
MULTIPURPOSE CONTROLS 365 / 7 DAY ADVANCED 1 OR 2 CHANNEL TIME SWITCHES
CONTACT RATINGS
SPECIFICATIONS
VOLTAGE
General Purpose
NC
24-277VAC
30A
30A
Ballast
120VAC 277VAC
30A 20A
10A 10A
Tungsten
120-277VAC
15A
2A
Pilot Duty
120-277VAC
720VA
720VA
Motor Load
120VAC 208-277VAC
1HP 2HP
1HP 2HP
Resistive
28VDC
30A
30A
TERMINAL RANGE: #14 - #16AWG for line input. #12 - #16AWG load outputs. OPERATING TEMPERATURE: -40° to +158°(-40° to 70°C).
1 CHANNEL Outdoor lighting Security lighting Parking lot lighting Canopy lighting
RATING NO
TIMING ACCURACY: Line Frequency. INPUT VOLTAGE: 120/208-240-277VAC, 50/60Hz.
APPLICATIONS
POWER CONSUMPTION: 5VA Max. ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for enclosure dimensions). ®
2 CHANNEL HVAC equipment Interior lighting Electric motors Refrigerator defrost control: condensers, heaters.
WIRING DIAGRAMS
DWZ100B DWZ100B SERIES SERIES
ORDERING INFO CATALOG NO.
UPC CODE
TIMER SUPPLY (VAC) 50/60Hz
NO. OF CHANNELS
DRY CONTACTS (UNPOWERED)
SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart.
DWZ100B
82189
120/208-240/277VAC
1
SPDT
DW200B
82190
120/208-240/277VAC
2
SPDT
ASTRONOMIC (DWZ100B only): Adjustable 10°- 60° Northern or Southern latitudes. Can be individually offset +/- 1 to 240 minutes from both sunset and sunrise times.
DW200B-0
FEATURES
TYPE
82231
120/208-240/277VAC
2
SPDT
TIMER SUPPLY TIMER SUPPLY
N
120
120V
N 208-240 120277 208-240
L
120V
277
SPDT
TIMER SUPPLY TIMER SUPPLYC
N
L N
277V
AC LINE INPUT AC LINE INPUT SELECT PROPER SELECTTERMINALS PROPER TERMINALS AND APPLY ONE VOLTAGE AND APPLY ONLY ONEONLY VOLTAGE
LOAD N
CH 1 CH 2 SPDT SPDT
CH 2 SPDT
DW200B DW200B SERIES SERIES
NO CNC NO NC
LOAD
208-240V208-240V 277V
C
SPDT
CH 1 SPDT
120
120V
N 208-240 120277 208-240 120V
L
208-240V208-240V 277V
277V
NO CNC NO C NC NO CNC NO NC
277
L LOAD N
L
L LOAD LOAD N
N
LOAD N
AC LINE INPUT AC LINE INPUT SELECT PROPER SELECTTERMINALS PROPER TERMINALS AND APPLY AND ONLY APPLY ONEONLY VOLTAGE ONE VOLTAGE
HOLIDAYS: 1 to 24 individual dates. DAYLIGHT SAVING: Automatic adjustment (can be omitted).
TWO SPEED TWOPUMP SPEEDWIRING PUMP WIRING
LEAP YEAR: Automatic Compensation scheduled ON or OFF, automatic operation then resumes.
SPECIFICATION WRITER’S GUIDE DWZ100B – 1. Furnish and install, where noted, a 1 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor. 11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 13. Controller shall be capable of having astronomic with 1-240 minutes, plus or minus offset from sunrise or sunset. 14. To order specify TORK Model DWZ100B. DW200B – 1. Furnish and install, where noted, a 2 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor. 11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure.
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup.
DIGITAL CONTROLS TORK 69
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 70
DZM SERIES
GREAT FOR LATCHING CONTACTORS
MOMENTARY OUTPUT 365 / 7 DAY ADVANCED LIGHTING CONTROL TIME SWITCH
APPLICATIONS
CALIFORNIA Title 24
Low voltage latching relays Direct wire to mechanically held contactors
General Purpose
120-277VAC
20A
Pilot Duty
120-277VAC
720VA
POWER CONSUMPTION: 4VA Max. ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for dimensions).
FEATURES
SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year.
RATING
OPERATING TEMPERATURE: -40˚ to 158˚F (-40˚ to +70˚C).
ASHRAE 90.1
ASTRONOMIC: Adjustable 10° - 60° Northern or Southern latitudes can be individually offset +/- 1 to 240 minutes from both sunset and sunrise times.
VOLTAGE
TERMINAL RANGE: #14 - #16AWG for line input. #12 - #16AWG load outputs.
energy
WIRING DIAGRAMS
ORDERING INFO CATALOG NO.
UPC CODE
TIMER SUPPLY (VAC) 50/60Hz
NO. OF CHANNELS
DZM200BP
82188
120/208-240/277
2
DZM200BP-0
82232
120/208-240/277
2
USB-MMP
82196
Memory Module Programmer
DRY CONTACTS (UNPOWERED)
SPDT Momentary SPDT Momentary
TIMER SUPPLY AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
N
120
208-240V
Includes software
277V
CH 1
DAYLIGHT SAVING: Automatic adjustment (can be omitted).
C
ON
CH 2
OFF
C
ON
OFF
MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS
LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
L
L PULSE ON
PULSE OFF
N
CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent scheduled retention with memory module. Supercapacitor provides 7 days of real time backup.
PULSE ON
PULSE OFF
N
SPECIFICATION WRITER’S GUIDE DZM 200BP only – 1. Furnish and install, where noted, a 2 channel digital time switch with portable Memory Module on front panel. 2. Memory Module shall be capable of being programmed at any one location and inserted into DZM200BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 9. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall have Permanent Schedule Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can additionally be offset 1 - 240 minutes for both sunset and sunrise. 16. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button for each channel. 17. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 18. Controller shall be capable of 2 independent momentary outputs ON and OFF for each channel. 19. To order specify TORK Model DZM200BP.
MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZM series unit. COPY FEATURE: Unit can be configured to copy program schedule to multiple memory modules. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature.
TORK 71
208-240 277
120V
HOLIDAYS: 1 to 24 individual dates.
DIGITAL CONTROLS
DZM200BP
TYPE
TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz.
responsible
SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart.
CONTACT RATINGS
SPECIFICATIONS
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 72
ELC SERIES
ENERGY AND LIGHTING CONTROL 1 & 2 ZONE LIGHTING CONTROL TIME SWITCH
THE DO-IT-ALL ENERGY & LIGHTING CONTROLLER
NEW!
FEATURES
CALIFORNIA Title 24
CATALOG NO.
UPC CODE
TIMER SUPPLY (VAC) 50/60Hz
NO. OF CHANNELS
OUTPUT CONTACTS
ELC71PC/120
82517
120
1
DPDT
ELC71PC/208-240
82518
208-240
1
DPDT
ELC71PC/277
82519
277
1
DPDT
ELC72PC/120
82520
120
2
SPDT
ELC72PC/208-240
82521
208-240
2
SPDT
ELC72PC/277
82522
277
2
SPDT
EPC-LC
82233
LCS115M
82082
Accessory Photo Sensor Accessory Momentary Switch
SENSOR EVENT: 32 sensor driven events allow individual programs for each day of the week.
BLOCK HOLIDAY: 10 holiday blocks can be set for individual days or for duration of any number of days and may use one of 3 holiday schedules.
MOMENTARY CONTACT: May be configured for momentary ON/OFF operation to control latching contactors. The ELC71/72 operates as a single-channel unit.
DIGITAL CONTROLS TORK 73
VOLTAGE
General Purpose
POWER CONSUMPTION: 6VA Maximum.
ORDERING INFO
HOLIDAYS: 26 holidays may be set using 10 individual dates, 10 month type (last Monday in May), or 6 specific holidays with one of 3 independent holiday schedules.
UNIVERSAL INPUT: 2 inputs may be assigned to any channel. SWITCHED INPUT: Accepts input from optional momentary or maintained switch. PHOTOSENSOR INPUT: Accepts input from optional sensor. EPC-LC (indoor/outdoor) has a range from 0 to 200 foot-candles. USER DEFINED INPUT: Accepts user supplied 4 – 20 milliamp sensor.
TYPE
OPERATING TEMPERATURE: -20°F to +140°F (-29°C to + 60°C).
ASHRAE 90.1
SCHEDULING: 128 time based events allow individual programs for each day of the week at a minimum 1 minute apart. Event types include ON, OFF, Duration, or Duty Cycle.
ASTRONOMIC: Adjustable 10° - 70° Northern or Southern latitudes. Settings can be offset from both sunset and sunrise times.
TIMING ACCURACY: Line frequency.
TERMINAL RANGE: #10 - #16AWG for line/load. #14 - #22AWG universal input.
energy
HVAC equipment Indoor/Outdoor lighting Meets indoor/outdoor lighting energy code requirements
CONTACT RATINGS
INPUT VOLTAGE: 120, 208-240, 277 50/60Hz (model specific). responsible
APPLICATIONS
SPECIFICATIONS
PULSE/TIME DURATION: 4 different ON settings from 1 second to 23 hours, 59 minutes, 59 seconds. DUTY CYCLE: 4 different ON and OFF patterns from 1 second to 23 hours, 59 minutes, 59 seconds. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. REMOTE OVERRIDE: Universal input may be programmed for timed override from a momentary or maintained dry contact switch.
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
RATING NO
NC
120/277VAC
20 A
10 A
Ballast
120VAC 208-277VAC
20A 10A
10A
Tungsten
120-277VAC
5A
Pilot Duty
120-240VAC
470VA
275VA
Motor
120VAC 208-277VAC
1HP 2HP
1⁄4HP 1⁄2HP
ENCLOSURE: Noryl® clear cover Indoor/ Outdoor NEMA 3R with lockable hasp (see page 153 for enclosure dimensions).
WIRING DIAGRAMS
ELC72
ELC71
SPST
MANUAL OVERRIDE: Keyboard button control until the next regularly scheduled ON or OFF, automatic operation then resumes. STAGGERED START: Optional stagger up time between channels, after a power outage; selectable from 5 seconds, 15 seconds, 30 seconds, 1 minute, 5 minutes, 10 minutes, and 15 minutes. CLOCK FORMAT: AM/PM or 24 hour format POWER OUTAGE BACKUP: Capacitor provides minimum of 1 week of real time backup for program and time of day. SPECIFICATION WRITER’S GUIDE Installer shall furnish and install Tork ELC71 single-channel (or ELC72, two-channel) electronic time control. The control shall have 24 hour, 7 day, 365 day, or astronomic capability with 128 events available. It shall also have 4 user-definable durations and duty cycle lengths plus automatic daylight savings time and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type.) Control shall have keyboard override until overridden again or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Controller shall have 7 day backup for real time with built in supercapacitor. The digital time display shall be 3⁄4” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Wiring terminals shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in NEMA 3R enclosure with clear-view cover and shall be lockable to guard against vandalism or tampering.
TORK 74
ELC SERIES
ENERGY AND LIGHTING CONTROL 4, 8 & 12 ZONE LIGHTING CONTROL TIME SWITCH
THE DO-IT-ALL ENERGY & LIGHTING CONTROLLER
NEW!
energy
CALIFORNIA Title 24 ASHRAE 90.1
HVAC equipment Indoor/Outdoor lighting Meets indoor/outdoor lighting energy code requirements
FEATURES
UPC CODE
TIMER SUPPLY (VAC) 50/60Hz
NO. OF CHANNELS
OUTPUT CONTACTS
ELC74*
82523
24/120/208-240/277
4
SPDT
ELC78
82524
24/120/208-240/277
8
SPDT
ELC712
82525
24/120/208-240/277
12
SPDT
EPC-LC
82233
Accessory Photo Sensor
LCS115M
82082
Accessory Momentary Switch
TORK 75
INPUT VOLTAGE: 24/120/208-240/277VAC, 50/60Hz.
General Purpose
RATING NO
NC
120 - 277VAC
20A
10A
Ballast
120 VAC 208-277 VAC
20A 10A
10A 3A
Tungsten
120-277VAC
5A
Pilot Duty
120-240VAC
470VA
275VA
Motor
120VAC 208-277VAC
1HP 2HP
1⁄4HP 1⁄2HP
WIRING DIAGRAMS
SPST
*Also CSA certified.
BLOCK HOLIDAY: 10 holiday blocks can be set for individual days or for duration of any number of days and may use one of 3 holiday schedules.
DIGITAL CONTROLS
VOLTAGE
ENCLOSURE: Metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions).
CATALOG NO.
SENSOR EVENT: 32 sensor driven events allow individual programs for each day of the week.
MOMENTARY CONTACT: May be configured for momentary ON/OFF operation to control latching contactors. The ELC74 operates as a two channel unit. The ELC78 operates as a four channel unit. The ELC712 operates as a six channel unit.
TYPE
OPERATING TEMPERATURE: -20°F to +140°F (-29°C to + 60°C).
ORDERING INFO
HOLIDAYS: 26 holidays may be set using 10 individual dates, 10 month type (last Monday in May), or 6 specific holidays with one of 3 independent holiday schedules.
UNIVERSAL INPUT: 8 inputs may be assigned to any channel. ELC74 includes 4. SWITCHED INPUT: Accepts input from optional momentary or maintained switch. PHOTOSENSOR INPUT: Accepts input from optional sensor. EPC-LC (indoor/outdoor) has a range from 0 - 200 foot-candels. USER DEFINED INPUT: Accepts user supplied 4 – 20 milliamp sensor.
TIMING ACCURACY: Line frequency.
POWER CONSUMPTION: 10VA Maximum.
SCHEDULING: 128 time based events allow individual programs for each day of the week at a minimum 1 minute apart. Event types include ON, OFF, Duration, or Duty Cycle.
ASTRONOMIC: Adjustable 10° - 70° Northern or Southern latitudes. Settings can be offset from both sunset and sunrise times.
CONTACT RATINGS
TERMINAL RANGE: #10 - #16AWG for line input. #10 - #16AWG for load output. #14 - #22AWG universal input.
responsible
APPLICATIONS
SPECIFICATIONS
PULSE/TIME DURATION: 4 different ON settings from 1 second to 23 hours, 59 minutes, 59 seconds. DUTY CYCLE: 4 different ON and OFF patterns from 1 second to 23 hours, 59 minutes, 59 seconds. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. REMOTE OVERRIDE: Universal input may be programmed for timed override from a momentary or maintained dry contact switch. MANUAL OVERRIDE: Keyboard button control until the next regularly scheduled ON or OFF, automatic operation then resumes.
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
STAGGERED START: Optional stagger up time between channels, after a power outage; selectable from 5 seconds, 15 seconds, 30 seconds, 1 minute, 5 minutes, 10 minutes, and 15 minutes. CLOCK FORMAT: AM/PM or 24 hour format. POWER OUTAGE BACKUP: The program and time of day are maintained for a minimum of 2 days by means of a capacitor. After two days, a lithium battery takes over and provides a minimum accumulated time of 1 year. The lithium battery should provide over 10 years of protection. COMPUTER INTERFACE: Unit may be programmed with a PC. SPECIFICATION WRITER’S GUIDE Installer shall furnish and install Tork ELC74 four channel (ELC78 eight channel or ELC712 twelve channel) electronic time control. The control shall have 24 hour, 7 day, 365 day or astronomic capability with 128 events available. It shall also have 4 (8) user-definable durations and duty cycle lengths plus automatic daylight saving time and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type). Control shall have keyboard override until overridden again or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Control shall provide 2 days of power outage carry-over without a battery. Control shall provide 10 years of power outage protection with a battery. The digital time display shall be 3⁄4” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Control shall be capable of interfacing (sending and receiving data) with a personal computer. Control shall be housed in a NEMA 1, lockable steel enclosure, to guard against vandalism or tampering.
TORK 76
CONTACT RATINGS
Resistive
TERMINAL RANGE: Relay #12AWG; input power terminals #14 - #22AWG; TOD/sensor terminals accept #18 - #22AWG. responsible
energy
APPLICATIONS
ASHRAE 90.1
Pilot Duty
POWER CONSUMPTION: 5VA Maximum.
NO
NC
120/240VAC 277VAC 120VAC 240/277VAC
20A 12A 20A 6A
10A
120/240/277VAC
5A
120/240VAC 277VAC
10A 3A 3A
LIGHT LEVEL
STAGE 1
470VA 690VA
4
5
6
STAGE 2
3
8
2
9 1
275VA 4
7
POWER
1
10
OTHER MOUNTINGS: LC200M mechanism only.
For 120 VAC Operation
NEUT 120V240V 277V
LINE INPUT
N H
WIRING DIAGRAMS
STAGE 1
C
NO NC
5
6
7
3
8
2
SET
ENCLOSURE: LC200 includes metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions).
EPC1 sensor supplied with unit.
Use to control two different outdoor lighting circuits utilizing one photocell. Sign lighting can turn ON at one ambient light level while parking lot lighting turns ON at a different light level.
9 10
RUN
STAGE 2
C
NO NC
OUTPUT 1 OUTPUT 2
WHITE BLACK
LOAD 1 TOD1 C TOD2
LOAD 2
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 50/60Hz
NO. OF ZONES
OUTPUT CONTACTS
PHOTOSENSOR INPUT: EPC1 included.
LC200
82111
120/240/277VAC
2
SPDT
DUAL OUTPUTS: with independent turn-ON adjustment for Stage1 and Stage 2.
LC200M
120/240/277VAC
2
5
6
STAGE 2
4
7
5
6
8
3
8
9
2
9 1
10
SET
LINE INPUT
10
RUN
H H
C
NO NC
C
NO NC
OUTPUT 1 OUTPUT 2
RED BLACK
LOAD 1 STAGE 1
STAGE 2
LOAD 2
SPDT For 277 VAC Operation NEUT 120V240V 277V
LINE INPUT
N H
C
NO NC
C
OUTPUT 1 OUTPUT 2
WHITE BLACK
NEUT 120V240V 277V
LINE INPUT
H H
LINE INPUT
N H
C
NO NC
C
NO NC
OUTPUT 1 OUTPUT 2
WHITE ORANGE
LOAD 1 LOAD 2
LOAD 2
For 240 VAC Operation
NEUT 120V240V 277V
NO NC
LOAD 1
SWITCHED INPUT: Can be used with a time switch for photocell ON of two different lighting circuits at different ambient light levels, then time-of-day OFF.
NEUT 120V240V 277V
7
3 2 1
For 120 VAC Operation
LIGHT LEVEL ACTIVATION: Turn ON is user settable from 2 to 100 footcandle; Independent light level adjustment for each zone. Turn OFF is a maximum of 2 times turn ON level. Built-in delay ON of 30 seconds to avoid reaction to lightning or headlights.
STAGE 1 4
POWER
82113
For 240 VAC Operation
LIGHT LEVEL
EPC
EPC1
ORDERING INFO FEATURES
Tungsten
OPERATING TEMPERATURE: -40°F to +140°F (-40°C to + 60°C).
TOD1 C TOD2
24 hour convenience stores Open wall parking structures Large canopies Building perimeters Atriums
Ballast
RATING
VOLTAGE
EPC
TYPE
INPUT VOLTAGE: 120/240/277VAC, 50/60Hz.
TOD1 C TOD2
SPECIFICATIONS
TOD1 C TOD2
STAGE LIGHTING TURN ON LEVEL
LIGHT LEVEL / TIME OF DAY OPTION 2 ZONES LIGHTING CONTROL TIME SWITCH
EPC1
LC200 SERIES
C
NO NC
C
NO NC
OUTPUT 1 OUTPUT 2
RED BLACK
LOAD 1
SPECIFICATION WRITER’S GUIDE LOAD 2 Furnish and install an electronic light sensor and control with dual outputs for two lighting zones. Each output shall be capable of a different user settable turn ON light level set For points277 fromVAC 2 to 100 footcandles. Turn ON to turn OFF ratio shall be 1:2. Controller shall also offer two digital inputs, which can accept a contact Operation closure from an independent time switch or EMS system, thereby allowing for independent time of day control. LINE INPUT OUTPUT 1 OUTPUT 2 NEUT 120V240V 277V
N H
C
NO NC
C
NO NC
WHITE ORANGE
LOAD 1 LOAD 2
DIGITAL CONTROLS TORK 77
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 78
DGU & DGLC SERIES
CODE SOLUTION FOR SMALL PROJECTS
NEW!
LIGHTING CONTROL WITH PHOTO OR OVERRIDE INPUT, 7 DAY 7 DAY LIGHTING CONTROL TIME SWITCH
TERMINAL RANGE: #12 - #18AWG for line/load. #18 - #26AWG sensor/switch input.
responsible
energy
APPLICATIONS
EXTERIOR LIGHTING Signage and store windows Security Parking lots
FEATURES
ASHRAE 90.1
Model EPC-A supplied with DGLC-A unit.
CATALOG NO. With optional Timed Override
82211
120-277VAC
1
DPDT
DGUM100A
82212
120-277VAC
1
DGUM100A-Y
82224
120-277VAC
1
SPDT Momentary SPDT Momentary
DGLC100A-NC
82223
120-277VAC
1
DPDT
DGLC200A-NC
82213
120-277VAC
2
SPDT
EPC-A
82112
Accessory Photo Sensor
SSA200R-24
14015
24VAC/24VDC
TRP-U
82030
120/277VAC
PHOTOSENSOR INPUT: Unique push button set-up assures accurate operation with automatic calibration that adjusts for wire size and distance. EPC-A photo sensor is included with the DGLC-A and may be ordered as an option for use with model DGU100A & DGUM100A.
MOMENTARY CONTACT - DGUM100A: 2 second contact closure ON & OFF to control mechanically held contactors or latching relays.
DIGITAL CONTROLS TORK 79
OUTPUT CONTACTS
VOLTAGE
Resistive
ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R . Suffix -NC Noryl® Indoor/Outdoor NEMA 3R with clear Lexan® cover. Suffix -Y metal Indoor enclosure NEMA 1. All with lockable hasp (see page 153 for dimensions).
RATING NO
NC
24-277VAC
20A
10A
Ballast
120VAC 277VAC
20A
10A
Tungsten
120VAC
15A
Motor
POWER CONSUMPTION: 6VA Maximum.
INPUT SUPPLY NO. OF (VAC) 50/60 Hz CHANNELS
DGU100A-Y
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
REMOTE OVERRIDE ON: Each channel has independent input for a maintained dry-contact closure. May use TORK model SSA200R-24 and TRP-U for timed override. May use with occupancy sensor as override.
UPC CODE
TYPE
Pilot Duty
OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C).
ORDERING INFO
SCHEDULING: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute.
LIGHT LEVEL ACTIVATION: Turn ON is user settable from 1 to 100 footcandle; Turn OFF is a maximum of 2 times turn ON level. Each channel has an independent setting. Includes a user settable delay before ON or OFF between 1 – 90 seconds.
TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120-277VAC, 50/60Hz (auto detection).
CALIFORNIA Title 24
INTERIOR LIGHTING Open office zoning Hallways Meeting and sales areas Stock rooms and warehouses
CONTACT RATINGS
SPECIFICATIONS
Resistive
120VAC 240VAC 120VAC 240VAC 28VDC
DGU100A
1HP 2HP
290VA 360VA 1⁄4HP 1⁄2HP
20A
10A
720VA
DGUM100A
DGU100A
WIRING DIAGRAMS DGU100A
DGLC100A
DGUM100A
SPDT Transformer Power Pack
SPST
DGUM100A
DGLC100A
DGLC200A
BLOCK HOLIDAY: 9 holiday blocks can be set for individual days or for duration of any number of days. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. CLOCK FORMAT: AM/PM or 24 Hour format. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup.
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
DGLC100A
DGLC200A
SPECIFICATION WRITER’S GUIDE DGU and DGLC SERIES - 1. Furnish and install, where noted, a 1 (2) channel 7 day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5. Controller shall have photo sensor input user adjustable per circuit between 1 and 100 footcandle turn ON level. 6. Each channel shall have and switched input to override circuit ON. 7. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of days. 8. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 9. Controller shall have automatic Leap Year correction. 10. Controller shall have Permanent Schedule Retention. 11. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 12. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button for each channel. 13. Unit shall have NEMA type 3R indoor/outdoor enclosure standard. 14. To order specify TORK Model DGU100A. (Alt 14. To order 1 channel momentary contact closure for latching contactor control specify DGUM100A). (Alt 14. To order controller with EPC-A photo sensor included in package specify TORK Model DGLC100A-NC (DGLC200A) with clear cover.
TORK 80
DLC400BP
FLEXIBLE INDOOR/ OUTDOOR LIGHTING CONTROLLER
4 ZONE LIGHTING CONTROL TIME SWITCH
responsible
energy
APPLICATIONS INTERIOR LIGHTING Open office zoning Hallways Meeting and sales areas Stock rooms and warehouses EXTERIOR LIGHTING Signage and store windows Security Parking lots
FEATURES CONFIGURABLE ZONES: Simple three position slide switch sets logic for each zone: Time ON/Time OFF, Photo ON/Photo OFF, or Photo ON/ Time OFF. SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week. Minimum 1 minute apart. ASTRONOMIC: 1. Adjustable 10° - 60° Northern or Southern latitudes. 2. Can be individually offset +/-1-240 minutes from both sunset and sunrise times. PHOTOSENSOR INPUT: EPC2 photo sensor included. LIGHT LEVEL ACTIVATION: Turn ON and OFF level is user settable from 1 to 100 footcandle. Each channel has an independent setting. REMOTE OVERRIDE: Maintained dry contact closure or use TORK Model SSA200R-24 for timed override with flash warning before OFF. May use with occupancy sensor as override.
DIGITAL CONTROLS TORK 81
CALIFORNIA Title 24
SPECIFICATIONS TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120/208 - 240/277VAC, 50/60Hz.
CONTACT RATINGS TYPE
VOLTAGE
General Purpose 24-277VAC, 30VDC
RATING NO
NC
30A
30A 10A
TERMINAL RANGE: #10 - #14AWG.
Ballast
120-277VAC
20A
OPERATING TEMPERATURE: -40°F to +158°F (-40°C to + 55°C).
Tungsten
120VAC
10A
Pilot Duty
120-277VAC
720VA
720VA
POWER CONSUMPTION: 30VA Maximum.
ASHRAE 90.1
ENCLOSURE: Metal Indoor/Outdoor NEMA 3 with lockable hasp (see page 153 for dimensions).
Model EPC2 supplied with unit. Memory Module Programmer optional
WIRING DIAGRAMS
With optional Timed Override
ORDERING INFO CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 50/60 Hz
NO. OF CHANNELS
OUTPUT CONTACTS
DLC400BP
82191
120/208-240/277
4
SPDT
USB-MMP
82196
Memory Module Programmer
SSA200R-24
14015
24VAC/24VDC
Includes Software SPDT
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year. HOLIDAYS: 1 to 24 individual dates. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. POWER OUTAGE BACKUP: Permanent schedule retention with memory module. Battery provides real time backup for 6 months cumulative. MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZS series unit. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature.
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
SPECIFICATION WRITER’S GUIDE
DLC400BP – 1. Furnish and install, where noted, a 4 zone lighting controller with photosensor input (TORK model EPC2 photosensor to be supplied with controller). 2. Memory Module shall be capable of being programmed at any one location and inserted into DLC400BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Each zone shall be capable of independent, user settable turn ON and turn OFF light level set points ranging from 1 to 100 footcandles. 5. Three position slide switches shall be provided for each of the 4 zones allowing for user settings based on a) time of day or b) combination time of day and light level or c) light level. 6. Controller shall provide 30 Amp General Purpose isolated contacts (unpowered) for each zone as well as a 500 ma, 24VDC output. 7. Controller shall have 1 digital input per channel for: a) remote contact closure which can be used to turn corresponding outputs ON/OFF outside of the normal control time or b) remote timed override which can be accomplished for the corresponding outputs with the use of TORK model SSA200R-24. 8. Enclosure shall provide separate wiring compartments for power connections and auxiliary connections. 9. Controller shall be capable of local override ON or OFF to the next scheduled event using the keypad for each zone. 10. Each zone shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can additionally be offset +/- 1–299 minutes for both sunset and sunrise. 11. Controller shall provide automatic daylight saving time (which can be omitted). Leap year adjustment shall be compensated for automatically. 12. Controller shall have 365 day holiday capability with 24 single dates and 4 seasons of unlimited duration. 13. Controller shall be capable of 99 set points with separate scheduling for each day of the week. 14. Controller shall have back-up capability: a) Schedule shall be retained for 40 years without power, b) real time shall be retained for 6 months using a field replaceable 9V lithium battery. 15. Unit shall have a NEMA type 3, metal indoor/outdoor enclosure.
TORK 82
LD SERIES
ADD A WARNING BLINK TO ANY CONTROL
EXTENDED LIGHTING CONTROL LIGHTING DELAY TIME SWITCH
INPUT VOLTAGE: 120/208/240/277VAC, 50/60Hz. TERMINAL RANGE: #10 - #16AWG. OPERATING TEMPERATURE: -22° to 150°F (-30° to +65°C).
ASHRAE 90.1
APPLICATIONS
CONTACT RATINGS
SPECIFICATIONS
POWER CONSUMPTION: 5VA Maximum.
®
®
ENCLOSURE: Metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions).
®
®
Open offices Gymnasiums Warehouses Outdoor recreation courts User-activated lights with time limits Match with photocontrol and timer to limit hours of use
RATING
TYPE
VOLTAGE
General Purpose Ballast
24/240VAC 277VAC 120VAC 208-277VAC
Tungsten
120-277VAC
5A
3A
Pilot Duty
120-240VAC 27VAC
470VA 690VA
275VA
Resistive
28VDC
20A
10A
NO
NC
20A 20A 20A 10A
10A 3A 10A 3A
WIRING DIAGRAMS LDSH WIRING
LDS WIRING
TORK TIME SWITCH
TORK TIME SWITCH
OUTPUT TERMINALS
OUTPUT TERMINALS OFF
NO
C
OFF
NC
MOMENTARY PUSH-BUTTON SWITCH
C ON OFF DO NOT APPLY VOLTAGE
N
TIME SWITCH INPUT
120
208 240
H
REMOTE INPUT
277 VAC
H C ON OFF DO NOT APPLY
INPUT POWER
VOLTAGE
NO
N
N
C
277 VAC
INPUT POWER
AUX. OUTPUT TERMINALS NC
208 240
120
TIME SWITCH INPUT
MAIN LOAD OUTPUT TERMINALS NC
120 VAC
ON
ON
N
NC
N
N
H
C
MOMENTARY PUSH-BUTTON SWITCH
H
REMOTE INPUT
NO
MAIN LOAD OUTPUT TERMINALS
NO
C
NC
NO
C
H
H
H
AUX LOAD
ORDERING INFO
FEATURES MAINTAINED INPUT WITH LOAD WARNING BLINK: LDS Series controls output load contacts based on power applied to the time switch input contact. At removal of power from the time switch input, LDS Series provides 1 second blink then keeps load contacts closed for an extra 1 or 5 minutes (user selectable) before turn off. MAINTAINED INPUT WITH AUXILARY WARNING: LDSH Series controls output load contacts based on power applied to the time switch input contact. At removal of power from the time switch input, LDSH Series closes a second set of contacts for a user supplied audible or visual warning device. The warning circuit closes for a selected time of 4 seconds (best for audible device or continuous, then keeps load contacts closed for an extra 1 or 5 minutes (user selectable) before turn OFF.
CATALOG NO.
LDS-A LDS LDSH-A LDSH
UPC CODE
81026 81025 81031 81028
INPUT SUPPLY (VAC) 50/60 Hz
120/208-240/277 120/208-240/277 120/208-240/277 120/208-240/277
MOMENTARY INPUT: Provides timed override when time switch input contact is unpowered (timer OFF). When activated during the warning period, load contacts are kept closed and timing starts. Both series can accept momentary input contact closure for ON to start the timing and OFF to end the timing. TIMED OVERRIDE SETTINGS: User may select override times of 1⁄2, 1, 11⁄2, 2, 6, 9, or 12 hours. Warning before OFF is always active after override time.
LOAD
OUTPUT CONTACTS
ENCLOSURE TYPE
SPDT
Metal Indoor NEMA 1
SPDT SPDT SPDT
Mechanism Metal Indoor NEMA 1 Mechanism
N
TORK TIME SWITCH
TORK TIME SWITCH
OUTPUT TERMINALS
OUTPUT TERMINALS OFF
NO
C
OFF
NC
MOMENTARY PUSH-BUTTON SWITCH
VOLTAGE
N
TIME SWITCH INPUT
N
120
208 240
H 120 VAC
REMOTE INPUT
277 VAC
H C ON OFF DO NOT APPLY
INPUT POWER
VOLTAGE
NO
N
N
C
NO
277 VAC
INPUT POWER
AUX. OUTPUT TERMINALS NC
208 240
120
TIME SWITCH INPUT
MAIN LOAD OUTPUT TERMINALS NC
NC
ON
ON
H
C
N
N
C ON OFF DO NOT APPLY
NO
MOMENTARY PUSH-BUTTON SWITCH
H
REMOTE INPUT
N
LOAD
N
MAIN LOAD OUTPUT TERMINALS C
NC
NO
C
H
H
H ON OFF COMMON
AUX LOAD MECHANICALLY HELD CONTACTOR WITH COIL CLEARING CONTACTS
ON
N
MECHANICALLY HELD CONTACTOR WITH COIL CLEARING CONTACTS
OFF COMMON
PHOTOCONTROL
N
N
TORK TIME SWITCH OUTPUT TERMINALS
APPLICATION EXAMPLE
Lighting for a high school’s tennis courts turns on during normal class hours when natural light diminishes using a 7 day time switch and photocell. After 3pm, staff members sometimes use the courts (the time switch is then off). A momentary pushbutton activates the LDSH for timed override of HID lighting. Five minutes before the lights go out, an auxiliary contact flashes an incandescent warning beacon (HID lighting can not be made to blink). Additional timed override can be arranged for via the momentary pushbutton.
APPLICATION WIRING
NO
C
NC
FLASHING LIGHT
H
120V
N
C
ON
H
OFF
N
N
120 208/240277
REMOTE INPUT TIME SWITCH INPUT
MOMENTARY PUSHBUTTON SWITCH
AUXILLARY OUTPUT NO C
LDSH
NC
INPUT POWER N
MAIN LOAD OUTPUT NO C
NC
120V
OFF N ON
H 120V N OFF
SWITCHED CIRCUIT TO TENNIS COURT LIGHTS
ON
N
MECHANICALLY-HELD 4 POLE LIGHTING CONTACTOR
SWITCHED CIRCUIT TO TENNIS COURT LIGHTS
480V CIRCUITS FROM PANEL
DIGITAL CONTROLS TORK 83
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 84
DGS SERIES
SIGNALING AND DUTY CYCLE 24 HOUR OR 7 DAY TIME SWITCH
31 DAY CYCLE TIME: AN INDUSTRY FIRST!
NEW!
SPECIFICATIONS TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120 - 277 VAC, 50/60 Hz (auto detection). TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C).
APPLICATIONS
POWER CONSUMPTION: 6VA Maximum.
Signaling Duty cycle
ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R with lockable hasp (see page 153 for enclosure dimensions). ®
CONTACT RATINGS TYPE
VOLTAGE
Resistive
RATING NO
NC
24-277VAC
20A
10A
Ballast
120VAC 277VAC
20A
10A
Tungsten
120 VAC
15 A
Motor
120 VAC 240VAC 120VAC 240VAC
Resistive
28VDC
Pilot Duty
720VA 1HP 2HP 20A
290VA 360VA 1⁄4HP 1⁄2HP DGS100A
FOR 120V/277VAC 10A
WIRING DIAGRAMS DGS100A FOR 208-240VAC DGS100A FOR 120V/277VAC
DG180A FOR 120V/277VAC
ORDERING INFO
FEATURES DG180A & DG280A: 56 ON & OFF set points provide individual daily programs. Minimum setting is 1 minute. DGS100A: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute. DUTY CYCLE: Two different ON/OFF patterns or signal durations may be programmed. The durations can be up to 23 hours, 59 minutes and 59 seconds in length. SKIP FUNCTION (24 HOUR UNITS ONLY): Each channel can be set for ACTIVE/SKIP operations that alternate from 1 - 31 days. This becomes an effective way to cycle loads on varying days within the month. Using the two-circuit DG280A, two loads can be set to operate on alternate days in a simple manner.
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 50/60 Hz
NO. OF CHANNELS
OUTPUT CONTACTS
24 HOUR MODELS DG180A
82206
120-277VAC
1
DPDT
DG280A
82207
120-277VAC
2
SPDT
DG280A-24
82220
24VAC
2
SPDT
120-277VAC
1
DPDT
DGS100A-12 82218
12VDC
1
DPDT
DGS100A-24 82219
24VAC
1
DPDT
DGS100A FOR 208-240VAC
DG180A FOR 208-240VAC
DG280A
7 DAY MODELS DGS100A
82205
DAYLIGHT SAVING: Automatic adjustment (can be omitted).
DG280A
LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or 24 hour. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup.
DIGITAL CONTROLS TORK 85
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
SPECIFICATION WRITER’S GUIDE DGS100A SERIES –1. Furnish and install, where noted, a 1 channel 7 day programmable digital time switch. (Alt 1 DG180 Series 1. Furnish and install, where noted, a 1 (2) channel 24 hour programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5. unit shall be capable of two duty cycle or signal durations from 1 second to 23 hours, 59 minutes and 59 seconds. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model DGS100A (Alt 12. Controller shall have a 31 day cycle to alternate days that programs are active or to be omitted. 13. To order specify TORK Model DG180A [DG280A]).
TORK 86
EJWT & E500T SERIES
NEW!
PERFECT FOR PROCESS CONTROL
DELAY, INTERVAL & PERCENTAGE TIME CYCLE TIME SWITCHES
SPECIFICATIONS
CONTACT RATINGS
TIMING ACCURACY: 1% of timing range.
TYPE
VOLTAGE
General Purpose Resistive
INPUT VOLTAGE: 120/240VAC, 60Hz. TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: 32°F to +122°F (0°C to + 50°C).
APPLICATIONS
POWER CONSUMPTION: 16VA Maximum.
EJWT
RATING NO
NC
120-240VAC
20A
10A
120-240VAC
20A
10A
Motor
120VAC 208-240VAC
1HP 2HP
1⁄4HP
Pilot Duty
120/240VAC
470VA
275VA
1⁄2HP
ENCLOSURE: Indoor NEMA 4X is standard (see page 153 for enclosure dimensions).
Poultry and livestock Agriculture or greenhouse Oil well pumping Ventilation Process control
E502T
E501T
EJWT
ORDERING INFO FEATURES EJWT – PERCENTAGE TIMER • 960 time combinations with two dials. • Cycle Time Dial sets 32 repeating cycles from 15 seconds to 24 hours. • Percentage ON Dial has 32 steps from 0% to 100%. • Repeats cycle as long as power is applied.
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60 Hz
OUTPUT CONTACT
EJWT
82513
120-240VAC
SPDT
E500T
82514
120-240VAC
SPDT
E501T
82515
120-240VAC
SPDT
E502T
82516
120-240VAC
SPDT
E500T – ON DELAY TIMER • Dial sets 32 time delay durations from 5 seconds to 3 hours. • External switch activated starts delay to ON. • Runs until external switch turns OFF.
WIRING DIAGRAMS
EJWT
E500T / E501T / E502T
E501T – AUTO OFF INTERVAL TIMER • Dial sets 32 time durations from 10 seconds to 12 hours. • Start/Stop button or External switch starts interval ON. • Automatically turns OFF at end of preset time. • START/STOP or External switch turns OFF. E502T – OFF DELAY TIME • Dial sets 32 time durations from 5 seconds to 3 hours. • External switch starts interval ON. • Automatically turns OFF at end of preset time. • External switch turns OFF.
DIGITAL CONTROLS TORK 87
E500T / E501T / E502T
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 88
DIN SERIES
1 OR 2 CHANNEL 7 DAY TIME SWITCH
ASHRAE 90.1
CONTACT RATINGS
SPECIFICATIONS
PANEL BUILDERS CHOICE
CALIFORNIA Title 24
NEW!
OPERATING TEMPERATURE: DIN100B: 14°- 131°F (-10°- +55°C). DIN200B: 14°- 113°F (-10°- +45°C).
Panel builders Indoor/Outdoor lighting Security systems HVAC equipment
CALIFORNIA Title 24
DIN100B
VOLTAGE
Resistive
POWER CONSUMPTION: 4VA Maximum.
ASHRAE 90.1
RATING NO
NC
120VAC
16A
16A
General Purpose
120VAC
8A
8A
Motor (DIN100 only)
120VAC
1⁄2HP
TERMINAL RANGE: #12 - #18AWG.
APPLICATIONS
TYPE
INPUT VOLTAGE: 120VAC, 50/60Hz.
MOUNTING: DIN rail #50022 (35mm) or flat surface using supplied adapter.
DIN200B
WIRING DIAGRAMS
DIN200B DIN200B
DIN100B
DIN100B
ORDERING INFO UPC CODE
DRY CONTACTS
CLOCK INPUT 50/60 Hz
NO. OF CHANNELS
NUMBER OF ON/OFF
DIN100B
82193
SPDT
120VAC
1
8
2
4 Channel A 3 Channel B
DIN200B
82192
SPDT
120VAC
35.80
Channel B (C2) Output
55.00
52.5
NC
14
8
7
6
1
2
3
DIN100B 35.80
46.00 60.00
5
6
1
2
NC
NO
2
3
4
5
Input
D
Channel B (C2)
NO
3
1
Channel A (C1)
14
8
7
6
1
2
3
85
85.00
45.00
7
6
60
Channel B (C2)
8
7
35.2
Channel A (C1) Output
52.5
NC
8
Channel A (C1)
Channel B (C2) Output
55.00
4
NC
NO DIN200B
CLOCK FORMAT: AM/PM.
Channel B (C2)
NO 85
MANUAL OVERRIDE: Until the next regular scheduled ON or OFF, automatic operation then resumes. POWER OUTAGE BACKUP: Battery retains time and schedule.
60
Channel B (C2) 85.00
SCHEDULING: 8 ON and OFF pairs of set points for DIN100B. 4 ON and OFF (CH A) and 3 ON and OFF (CH B) pairs of set points for DIN200B. Individual programs on each day of the week. Minimum setting is 1 minute.
CATALOG NO.
45.00
FEATURES
4
35.2
5
4
5
Channel A (C1)
Channel A (C1) 46.00 60.00
DIGITAL CONTROLS TORK 89
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
Channel A (C1) Output
Input
TORK 90
SMC SERIES
5401 SERIES
SPECIFICATIONS
MOMENTARY CONTACT ADAPTER
INCREASED AMPERAGE & VOLTAGE SWITCHING 40 AMP CONTACTORS
INPUT VOLTAGE: 120VAC, 50/60Hz. TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C). POWER CONSUMPTION: 6VA max.
APPLICATIONS
ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R with lockable hasp (see page 153 for dimensions).
Converts maintained contacts for pulse switching Timer to latching contactor control Photocell to latching contactor control Signaling
CONTACT RATINGS
5401
Lighting loads Exhaust fans Electric and hot water heaters Refrigeration and defrosting
5441
TYPE
VOLTAGE
RATING
Resistive
120-600VAC
50A
FLA
120-600VAC
40A
Motor
120VAC 240VAC 480VAC 600VAC
3HP 7.5HP 20HP 25HP
ORDERING INFO UPC CODE
INPUT SUPPLY (VAC) 50/60Hz
OUTPUT CONTACTS
SMC3D
52011
120
SPDT Momentary
CONTACT RATINGS NC
Resistive
120VAC
10A
10A
General Purpose
120VAC
10A
10A
Motor
120VAC
1⁄4HP
NC
SMC 3D ON RELAY NC NO C
5401
H 120VAC N
INPUT 120 VAC OFF RELAY
BLACK
NC NO C
WHITE
Control circuit from Time Switch
ON PULSE
120VAC
NEUTRAL
N
L
C
NO
AUX
LOAD
DIGITAL CONTROLS TORK 91
LOAD
N
LOAD
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
NC H
CONTACT
277VAC 480VAC
81021 81022
120VAC 208VAC 277VAC 480VAC
Wire B, C the sa
NO. AOF CONTACTORS
120
1
120
4
OUTPUT CONTACTS N
B
3PST
120VAC 208VAC 277VAC 480VAC
Control circuit from Time Switch
24VAC Wire other circuits B, C and D respectively
120 to 480VAC
{
A
N
C
D
C
D
A
Keep low voltage wires inside this compartment.
120VAC 208VAC 277VAC 480VAC
B
Wire contactors B, C and D the same as A.
D
B
120VAC 208VAC 277VAC 480VAC
Wire other c
3PST
C
A
24VAC
5441
120 to 480VAC
Control circu
B
Control circuit from Time Switch
120VAC
C
D
Keep low voltage wires inside this compartment.
Wire other circuits B, C and D respectively
120VAC
120 VAC
SMC 3D ON RELAY
OFF RELAY
NC NO C
NC NO C
PUSH ON
{
N
120VAC
COIL VOLTS
{
TORK DIGITAL CONTROL TERMINAL BLOCK
MAINTAINED CONTACT INPUT
L
5401
{
UPC 120VAC CODE 208VAC
120VAC 208VAC 277VAC 480VAC
Control circuit from Time Switch
Wire contactors B, C and D the same as A.
H
REALAY CONTACTOR
L
CATALOG NO.
5441
PUSH OFF
OFF PULSE
120VAC 208VAC 277VAC 480VAC
5
120VAC 208VAC 277VAC 480VAC
120VAC 208VAC 277VAC 480VAC
ORDERING 5440INFO
N
PUSH ON
LOW VOLTAGE LATCHING RELAY OR MECHANICALLY HELD CONTACTOR
WHITE
ENCLOSURE: 5401 - Metal NEMA 3 enclosure. 5441 - Metal NEMA 1 Indoor enclosure (see page 153 for enclosure dimensions).
TORK DIGITAL CONTROL TERMINAL BLOCK MAINTAINED CONTACT INPUT
NO
BLACK
EASY WIRING: Includes 120 volt control wiring compartment. 5441 has terminal strip pre-mounted for quick connection.
SMC 3D 120VAC, 240VAC Input – Sustained voltage 120VAC WIRING DIAGRAMS 277VAC, 30VDC Momentary Contacts (unpowered) 30 Amps inrush
C
5401
CONTACT RATINGS: Can switch up to 40 AMPS per pole from 120VAC to 600VAC, one to three circuits simultaneously.
{
NO
{
MOMENTARY OUTPUT: SMC3D provides two dry output contacts. The ON contact provides a 2 second contact closure (pulse) when power is applied to the input contacts. The OFF contact provides a 2 second pulse when power is removed from the input contacts.
RATING
VOLTAGE
WIRING DIAGRAMS
FEATURES
{
TYPE
MAINTAINED INPUT: SMC3D accepts maintained input power from any 120 volt control. When power is applied or removed a short contact closure (pulse) is created on the dry output contacts.
Coil Data: 120VAC @ 60Hz 6VA Holding/seal; 60VA inrush
{
FEATURES
CATALOG NO.
{
APPLICATIONS
TORK 92
HPS STARTER
SPECIFICATIONS
FOR HIGH PRESSURE SODIUM LAMPS STARTING AID
LINE VOLTAGE: 105 - 347VAC. LAMP VOLTAGE: 55 or 100VAC.
TRP SERIES
SPECIFICATIONS
LOW VOLTAGE SWITCHING TRANSFORMER RELAY POWER PACKS
CONTACTS: SPST contacts. CONTACT RATING: 20 Amps Ballast @ 120 or 277VAC. 15 Amps Tungsten @ 120VAC. 1.0 Horsepower @ 120VAC.
LAMP WATTAGE: 35 to 400 watts. OPERATING TEMPERATURE: -40°F to +221°F (-40°C to + 105°C).
APPLICATIONS
LEAD LENGTH: 9 inches. ENCLOSURE: Durable, high temperature
Designed to operate as a starting aid, for all H.P.S. ballasts from 35 to 400 watts, with lamp voltage of 55 or 100 volts.
Lexan® housing.
APPLICATIONS
TEMPERATURE RANGE: 0° to 150°F (–18° to 66°C). Pre-wired in metal enclosure.
Low voltage switching of line voltage lighting circuits up to 20 Amp ballasts or 15 amp tungsten loads. Also up to 1.0 HP motors for ventilating and exhaust fans. Low voltage switching by digital or mechanical controls for higher amperage loads including those of two different voltages.
ORDERING INFO FEATURES SMART VOLTAGE: Delivers appropriate trigger spikes for lamp ignition, then reduces voltage to good lamps. Continues to feed voltage spikes to old or poorly working lamps.
CATALOG NO.
UPC CODE
DESCRIPTION
HPS30
81030
High Pressure Sodium Starter
BALLAST
design, color coded for ease of installation.
BLACK RED TAP
H.P.S. STARTER WHITE
LINE
TORK 93
ORDERING INFO CATALOG NO.
UPC CODE
TRP-1**
82032
TRP-2**
82033
TRP400*
82132
TRP402*
82133
TRP800*
82135
TRP802*
82136
DESCRIPTION
Single Transformer Relay Powerpack Single Transformer Relay Powerpack Four Transformer Relay Powerpack Four Transformer Relay Powerpack Eight Transformer Relay Powerpack Eight Transformer Relay Powerpack
INPUT VOLTAGE
120VAC 277VAC 120VAC 277VAC 120VAC 277VAC
SURGE SUPPRESSOR FOR HIGH ELECTRICAL NOISE
EASY INSTALLATION: Universal 3 wire
DIGITAL CONTROLS
ENCLOSURE: Metal NEMA 1 Indoor enclosure (see page 153 for enclosure dimensions).
*Not for use with occupancy sensors. **For replacement parts only. For newer style Transformer Relay Power Pack, see TRP-U on page 116.
WIRING DIAGRAMS
HIGH GRADE MATERIAL: All components are sealed with high grade die-electric material to protect against contaminants and other adverse environmental conditions.
WEIGHT: 7 oz.
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
COMMON
CENTER CONTACT LAMP SHELL
APPLICATIONS For high electrical noise interference, recommended for all digital controls.
ORDERING INFO CATALOG NO.
UPC CODE
DESCRIPTION
90058-1
81024
Surge Suppressor
TORK 94
IN-WALL TIMERS
FEATURES QUICK LOOK
SS720A SERIES
SPECIFICATIONS
24 HOUR OR 7 DAY DIGITAL IN-WALL TIME SWITCH
TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 125VAC, 60Hz. WIRE SIZE: #14AWG. OPERATING TEMPERATURE: 32°F to +104°F (0°C to +40°C).
APPLICATIONS
SS700Z
SS721Z
SS720A
701A
SSA
SSA-R24
SS
D1060 D212
A
C
Page No.
99
99
98
101
102
102
103
104
105
106
Timer Type
7 Day Digital
7 Day Digital
7 Day Digital
24 Hour Mechanical
Auto OFF Digital
Auto OFF Digital
Auto OFF Electronic
Auto OFF Electronic
Auto OFF Mechanical
Auto OFF Mechanical
Voltage
120/277
120/277
120
120
120/277
24
24/120/ 208-240/277
120
ON
1 min.
1 min.
1 min.
30 min.
OFF
1 min.
1 min.
1 min.
30 min.
Minimum Settings
5 min-12 hr 5 min-12 hr 10-60 min. 1 min-18 hr 10 min-8 hr 10 min-8 hr 2-12 hr
Outdoor security lighting Interior lights for lived-in look Fans and motors Appliances
125/250/277 125/250/277 Various 2 min-12 hr
Various 2 min-12 hr
ORDERING INFO Manual Override
Yes
Yes
Sunrise/Sunset
Yes
Yes
ON/OFF Set Points
10 Pair
10 Pair
Yes
Yes
SCHEDULING: 7 ON and OFF pairs of set points for individual programs on each day of the week. Minimum setting is 1 minute. 7 Pair
24
Flash Warning
TORK 97
Capacitor
Capacitor
Battery
Switch Type
SPST
SPST
SPST
Resistive Ratings
16A
16A
15A
SPST
NEW!
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60 Hz
COLOR
SS720A
14017
120
White
SS720AA
14018
120
Light Almond
RANDOM MODE: Varies ON and OFF times to create "lived in" look when away. Yes
Audible Warning
Power Outage Backup
FEATURES
Yes
Yes
Yes
Capacitor
Capacitor
SPST
15 & 20A 800W/1200W
Yes
DAYLIGHT SAVING: Manual button push for one hour adjustment.
Yes
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
CONTACT RATINGS TYPE
VOLTAGE
RATING
General Purpose
120VAC
15A
WIRING: Requires a neutral.
Resistive
120VAC
15A
CLOCK FORMAT: AM/PM.
Tungsten
120VAC
15A
Motor
120VAC
1HP
Electronic Ballast
120VAC
500VA
SPDT
SPST or SPDT
SPST
SPST
SPST or DPST
POWER OUTAGE BACKUP: Rechargeable Ni-MI battery retains time and schedule.
1A
4A or 7.5A
15
20/10/10A
20/10/10A
WALL PLATE: Supplied with standard single gang decorator wall plate.
TORK 98
SS700Z & SS721Z SERIES
BACKUP WITHOUT BATTERY, ECO FRIENDLY!
NEW!
SUNSET / SUNRISE, ASTRONOMIC 7 DAY IN-WALL TIMER
SS700Z SERIES
TIMING ACCURACY: Line frequency.
energy
RATING
INPUT VOLTAGE: 120/277VAC, 50/60Hz.
Resistive
16A
120/277VAC
16A
WIRE SIZE: #12AWG input/output - #16AWG 3-way (remote).
Ballast
10A
120/277VAC
13A
Tungsten
8A
120VAC
8A
Pilot Duty
360VA
120VAC
720VA
Motor
1⁄2HP
120VAC
1HP
CALIFORNIA Title 24 ASHRAE 90.1
Outdoor security lighting Interior lights for lived-in look Fans and motors Appliances
SS721Z SERIES
VOLTAGE
TYPE
OPERATING TEMPERATURE: 32°F to +104°F (0°C to + 40°C).
responsible
APPLICATIONS
CONTACT RATINGS
SPECIFICATIONS
With wall plate (not included)
RATING
WIRING DIAGRAMS
ORDERING INFO
CONTACT RATINGS
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 50/60 Hz
SWITCH TYPE
COLOR
SS700Z
14019
120/277
SPST
White
SS700ZA
14020
120/277
SPST
Light Almond
SS721Z
14027
120/277
SPST
White
SS721ZA
14028
120/277
SPST
Light Almond
FEATURES SCHEDULING: 10 ON and OFF pairs of set points for individual programs on each day of the week. 11 day groups speed programming. Minimum setting is 1 minute. ASTRONOMIC: Sunset and sunrise times are adjustable from 10°- 60° Northern or Southern latitudes. Can be individually offset +/- 1-240 minutes for earlier or later operation. RANDOM MODE: Varies ON and OFF times to create lived in look when away. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
MANUAL MODE: Does not run programs until set to AUTO (automatic) mode. VACATION MODE: No operation when away.
WIRING DIAGRAM: INSTALLATION SS721Z
EASY WIRING: SS700Z does not require a neutral, can be used as a 3-way switch. SS721Z Requires a neutral, can be used as a 3-way switch.
H
COMMERCIAL GRADE SPECS: Control lighting contactors and 277VAC loads. Compatible with CFL lamps.
Blue
Red
Black
Load White
CLOCK FORMAT: AM/PM. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 2 days of real time backup.
Black
N
N
Ground
WIRING DIAGRAM: THREE-WAY INSTALLATION SS721Z Connect a wire inside the gang-box between Traveler A and Hot.
ORDERING INFO Green Black
Blue
Black
Traveler A
H
Black Red Traveler B
Load White
N
N
Ground
Green
IN-WALL TIMERS TORK 99
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 100
701A & 711A SERIES
SPECIFICATIONS SPECIFICATIONS
24 HOUR IN-WALL TIME SWITCH
INPUT VOLTAGE: 125VAC, 60Hz. WIRE SIZE: #14AWG.
SSA SERIES
SPECIFICATIONS
DIGITAL AUTO OFF IN-WALL TIME SWITCH
TIMING ACCURACY: .002%. INPUT VOLTAGE: 120/277 VAC, 50/60Hz.
OPERATING TEMPERATURE: 32°F to +104°F (0°C to +40°C).
APPLICATIONS
WIRE SIZE: #18AWG.
APPLICATIONS Offices, meeting rooms, library aisles Stock and equipment rooms Exhaust fans – work areas, utility rooms, bathrooms Hot tub heaters and circulating pumps Timed override lighting and HVAC for after hours and for loads controlled by electromechanical or digital time switches.
Porch or patio Doorway Pool Outdoor security lighting
ORDERING INFO CATALOG NO.
UPC CODE
INPUT SUPPLY
SSA100
14010
120/277 VAC
SSA200
14011
120/277 VAC
SSA100R-24
14014
24VAC/24VDC
SSA200R-24
14015
24VAC/24VDC
LCS115M
82082
OPERATING TEMPERATURE: 0°F to +100°F (-17°C to +37°C). TIME SETTINGS
OUTPUT CONTACTS
Minutes: 5, 15, 30 Hours: 1, 3, 6, 9, 12 Minutes: 10, 20, 40 Hours: 1, 11⁄2, 2, 4, 8 Minutes: 5, 15, 30 Hours: 1, 3, 6, 9, 12 Minutes: 10, 20, 40 Hours: 1, 11⁄2, 2, 4, 8 Momentary Switch for Override (white)
SPST SPST SPDT SPDT SPST
CONTACT RATINGS
CLOCK FORMAT: AM/PM marked on dial. WALL PLATE: Supplied with single gang wallplate.
INPUT SUPPLY (VAC) 60 Hz
8-IN-1 TIMING: Choose from 8 preset ON intervals.
COLOR
701A
10113
125
White
701AA
10118
125
Light Almond
711A
10114
125
White
MANUAL SCROLL-UP: Option allows adjustment in 10 minute intervals. FLASH WARNING: Optional flicker feature turns load off for 1 second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle.
CONTACT RATINGS TYPE
VOLTAGE
General Purpose
800W 800W 1200W 1⁄6HP
Pilot Duty 30V 1V min.
120VAC 30V 1V min.
240VA 1A 100µA
RATING 701A SERIES
711A SERIES
125 VAC
20A
15A
Resistive
125 VAC
20A
15A
Tungsten
125 VAC
1500W
1250W
Motor
125 VAC
1 HP
1⁄2HP
Ballast
SSA100/200
SSA100/200R-24
WIRING DIAGRAMS SSA100/200
AUDIBLE WARNING: Optional beep will sound every 12 seconds during the last 2 minutes of timed cycle.
BLACK
HOT
GREEN
120V GROUND
GREEN /YELLOW
277V GROUND
RED
TAMPER RESISTANT: Time ON interval preset hidden behind wall plate.
RED
EASY SET: Dip switches provide quick set-up of timing and options. EASY WIRING: No neutral needed, great for retrofit. BACKLIT DISPLAY: Numerical read-out of time remaining includes graphic bar showing time remaining in 10% increments. Stands out strongly in lighted and dark areas.
BLACK ORANGE BLUE GREY
REMOTE OVERRIDE
(+) 24VAC or (–) VDC
NC C NO
YELLOW YELLOW
SSA200R-24 USING TRP TRANSFORMER RELAY POWERPACK BLACK ORANGE BLUE GREY
REMOTE OVERRIDE
NC C NO
YELLOW YELLOW
LOW VOLTAGE
20 AMP LOAD
L
RED
WALL PLATE: Supplied with white standard single gang decorator wall plate. SSA-R24: Offers low voltage control with SPDT output and includes momentary input.
NEUTRAL
LOAD
RED
WIRING: Requires a neutral.
Motor
120VAC 120VAC 277VAC 120VAC
RED BLACK BLUE
N
BLACK
VACATION MODE: Set timer OFF with no change of tripper settings.
Tungsten
RED
BYPASS SWITCH: Slide switch for ON, OFF, or TIMER (automatic) operation.
NEW!
UPC CODE
RATING
TORK TRP
SCHEDULING: Minimum ON setting is 30 minutes. Dial has 48 captive trippers.
CATALOG NO.
VOLTAGE
WHITE
ORDERING INFO FEATURES
TYPE
FEATURES
L
IN-WALL TIMERS TORK 101
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 102
SS SERIES
SPECIFICATIONS
AUTO OFF IN-WALL TIME SWITCH
TIMING ACCURACY: ±5% @ 60° to 80°F.
D SERIES
SPECIFICATIONS SPECIFICATIONS
NEW!
ELECTRONIC AUTO OFF IN-WALL TIME SWITCH
TIMING ACCURACY: Line voltage. INPUT VOLTAGE: 120VAC, 60Hz.
INPUT VOLTAGE: 24/120/208-240/277VAC, 50/60Hz.
WIRE SIZE: #14AWG. OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C).
WIRE SIZE: #18AWG. OPERATING TEMPERATURE: 0°F to +100°F (-17°C to +37°C).
APPLICATIONS
APPLICATIONS Whole house fans Indoor/Outdoor lighting Bathroom fans and lights Self storage
Bathroom fans and lights Indoor/Outdoor lighting Storage areas Hospitality areas
ORDERING INFO
ORDERING INFO FEATURES VARIABLE TIMING: Choose from 1 minute to 18 hours. FLASH WARNING: “F” suffix models with flicker feature turns load off for 1⁄2 second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle. AUDIBLE WARNING: “B" suffix model will buzz that every 12 seconds during the last 2 minutes of timed cycle. TAMPER RESISITANT: Time ON interval preset is hidden behind wall plate. EASY SET: Small screw driver adjustment provides quick set-up of timing. EASY WIRING: No neutral needed, great for retrofit.
CATALOG NO.
INPUT SUPPLY (VAC) 50/60Hz
WARNING BEFORE TIME OUT
SWITCH TYPE
SS20
14005 24/120/208-240/277
None
Single pole
SS20F
14008 24/120/208-240/277
*Flicker
Single pole
SS13F
14007 24/120/208-240/277
*Flicker
3-way
SS13B
14006 24/120/208-240/277
**Beep
3-way
*Flicker feature turns load OFF for ½ second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle. **Beep feature will begin a ½ second audible warning every 12 seconds during the last 2 minutes of timed cycle.
CONTACT RATINGS TYPE
SS13F & SS13B
3-WAY: SS13 SERIES replaces standard 3-way switch with no re-wiring. COLOR: White.
UPC CODE
SS20 & SS20F
FEATURES VARIABLE TIMING: Button push changes time ON setting. D1060M: 10, 20, 30, 60 minute. D212H: 2, 4, 8, 12 hour. LED DISPLAY: Indicator moves to new range as timer counts down. TAMPER RESISTANT: Time ON interval preset. EASY SET: No adjustments, just wire and go! WIRING: Requires a neutral. THREE COLORS: Ivory, Light Almond, White.
MINIMUM LOAD
CONTACT RATINGS
VOLTS
WATTS
.25-4.0A Resistive .25-4.0A Ballast* .25-4.0A Tungsten 1⁄8HP @ 120VAC 1⁄3HP @ 240VAC .50-7.25A Resistive .50-7.25A Ballast* .50-4.0A Tungsten 1⁄6HP @ 120VAC 1⁄2HP @ 204VAC
24 120 208 240 277 24 120 208 240 277
6 30 50 60 70 12 60 105 120 150
CATALOG NO.
UPC CODE
INPUT SUPPLY (VAC) 60Hz
TIME SETTINGS
OUTPUT CONTACTS
D212H
14021
120
Ivory
2, 4, 8, 12 HOURS
D212HA
14022
120
Light Almond
2, 4, 8, 12 HOURS
D212HW
14023
120
White
2, 4, 8, 12 HOURS
D1060M
14025
120
Ivory
10, 20, 30, 60 MINUTES
D1060LA
14024
120
Light Almond
10, 20, 30, 60 MINUTES
D1060MW
14025
120
White
10, 20, 30, 60 MINUTES
CONTACT RATINGS TYPE
VOLTAGE
RATING
General Purpose
120VAC
15A
Resistive
120VAC
1000W
Tungsten
120VAC
1000W
Motor
120VAC
1⁄4HP
*Not compatible with compact fluorescent lamps (CFL) and electronic fluorescent ballasts.
IN-WALL TIMERS TORK 103
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 104
A SERIES
SPECIFICATIONS
SPRINGWOUND AUTO OFF IN-WALL TIME SWITCH
INPUT VOLTAGE: 125/250/277VAC, 50/60Hz. TERMINAL SIZE: #12AWG.
C SERIES
SPECIFICATIONS
COMMERCIAL STYLE SRINGWOUND AUTO OFF IN-WALL TIME SWITCH
INPUT VOLTAGE: 125/250/277VAC, 50/60Hz. TERMINAL SIZE: #12AWG.
OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C).
OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C).
ORDERING INFO
APPLICATIONS Whole house fans Indoor/Outdoor lighting Bathroom fans and lights Self storage
CATALOG UPC NO. CODE 15 MINUTE MAX.
Wallplate not included
A515MH
15020
A515MHW
15120
A515M
15013
A515MW
15113
A515MA
15127
HOLD FEATURE
With Hold
APPLICATIONS COLOR
Ivory White Ivory
No Hold
Wallplate included
Ventilating fans HVAC Whirlpools Self storage Motors and pumps
White Light Almond
30 MINUTE MAX.
A530MH
15021
A530MHW
15121
A530M
15014
A530MW
15114
CONTACT RATINGS FEATURES
TYPE
VARIABLE TIMING: Twist knob for time ON setting. Time ON lengths from 15 minutes to 12 hour vary by model.
VOLTAGE
RATING
125VAC 250VAC 277VAC 125VAC 250VAC 277VAC
20A 10A 10A 20A 10A 10A
125VAC
7A
Resistive Inductive
HOLD FEATURE: Some models have position for constant ON.
Tungsten
EASY SET: No adjustments. Just wire and go! EASY WIRING: No neutral required. Great for retrofit! Use as single or in multi-gang box with no de-rating.
125VAC 250VAC
Motor
1HP 2HP
A530MA
15022
A560MHW
15122
A560M
15015
A560MW
15115
A502HHW
15123
A502H
15016
A502HW
15116
3
9
6
0
0
12
12
3
9
6
9
A506HHW
15125
A506H
15018
9
A506HW
15118
With Hold
No Hold
Ivory White
With Hold No Hold
With Hold No Hold
FEATURES VARIABLE TIMING: Twist knob for time ON setting. Time ON lengths from 15 minutes to 12 hour vary by model.
Ivory
HOLD FEATURE: Some models have position for constant ON.
White
EASY SET: No adjustments. Just wire and go!
White
EASY WIRING: No neutral required. Great for retrofit!
Ivory
SWITCH TYPE: SPST, except C460M and C412H – DPST
White
COLOR: Metal-brushed aluminum.
White
WALL PLATE: Includes real metal wall plate with screw mounting, to add extra security for commercial applications.
Ivory
TYPE
VOLTAGE
RATING
125VAC 250VAC 277VAC 125VAC 250VAC 277VAC
20A 10A 10A 20A 10A 10A
Tungsten
125VAC
7A
Motor
125VAC 250VAC
1HP 2HP
Resistive Inductive
3
A512HH
15026
A512HHW
15126
A512H
15019
A512HW
15119
9
0 3
21
CAUTION: This timer is not to be used in precision timing applications where inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.). 6
15501
HOLD FEATURE
No Hold
30 MINUTE MAX.
C530M
15503
No Hold
60 MINUTE MAX.
NEW!
C560M
15505
No Hold
C560MH
15506
With Hold
C460M*
15011
No Hold
2 HOUR MAX.
C502H
15507
No Hold
6 HOUR MAX.
C506H
15511
No Hold
12 HOUR MAX.
21
T OR K
1
C515M
White
With Hold
Ivory NEW!
White
C512H
15513
No Hold
C512HH
15514
With Hold
C412H*
15010
No Hold
*DPST switch type.
1
2
CATALOG UPC NO. CODE 15 MINUTE MAX.
12 HOUR MAX.
0 1
6
2
Light Almond
ORDERING INFO
CONTACT RATINGS
1
T OR K
2
White
6 HOUR MAX.
POT
2
0 12
No Hold
2 HOUR MAX.
POT
0
White Ivory
15128
A560MH
COLOR: Ivory, Light Almond, White.
12
Ivory
60 MINUTE MAX.
SWITCH TYPE: SPST. WALL PLATE: Fits standard or decorator style wall plates, see below (not included).
With Hold
9
No Hold
Ivory White
CAUTION: This timer is not to be used in precision timing applications where inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.).
All A Series timers have SPST switch type.
IN-WALL TIMERS TORK 105
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 106
OCCUPANCY SENSORS
OSWS SERIES
SENSOR TECHNOLOGY & PLACEMENT GUIDE TECHNOLOGY PIR AND ULTRASONIC
A Passive Infrared Sensor (PIR sensor), is a device that measures infrared radiation (IR), or heat, from objects in its field of view. Because it only receives information, it is considered passive. The IR sensor views a human body as an IR generating object. The lens of the occupancy sensor breaks up the field of view into IR sensitive bands. The occupancy sensor is designed to only react when heat is sensed moving from band to band. For PIR occupancy sensors to work object must have direct “line of sight” to the PIR sensor.
PLACEMENT GUIDELINES
PIR SENSOR, DECORATOR STYLE IN-WALL OCCUPANCY SENSOR
• Designed for ceiling mounting at a height of 8-10 feet (mounting sensor at greater heights decreases the sensitivity to motion, while lower mounting height will decrease range). • The sensor needs a visually unobstructed view of the normally occupied workspace and entry door(s). • Avoid sensor placement with a direct view out a doorway. Placing the sensor offset from the center and away from the door is recommended. Both technologies show higher sensitivity closer to the sensor to allow small • If the occupant cannot see a PIR sensor from their normal work movements to be noticed. Sensitivity reduces further away from the sensor and position, the sensor will not be able to detect their presence. may require a walking step to activate the sensor. • File cabinets, partitions, or walls are typical types of obstructions. If there are other obstructions between the sensor and the occupant, an ultra-sonic or dual technology ceiling sensor is recommended. • When the light level feature is used, mount within 15 feet of the widows or skylight and avoid mounting the sensor close to lighting WALL SENSOR fixtures. A Wall Switch Sensor provides a 180° coverage pattern, extending outward • Place the sensor no closer than 5 feet to an HVAC airCEILING duct whenAND usingWALL OCC SENSOR SENSING PATTERNS CEILING AND WALL OCC SENSOR SENSING PATTERNS from the sensor. This will allow for instant turn ON when an occupant enters the dual technology sensors. space. Total area covered will be over 400 square feet. • Open office designs encourage placement of the sensors to allow overlapping coverage of small motion range and a clear view into • Proper placement gives the sensor a clear line of sight to the entry door each cubicle. Walking step motion may cover the entry to the space. without viewing the hallway. Dual technology units provide added sensitivity to small motion. • The occupant must be able to see the sensor from their normal work position otherwise the sensor will not be able to detect their presence. • For offices where there are other obstructions between the sensor and the occupant or the entry door, a ceiling sensor is required. An Ultrasonic Sensors (US sensor) is a technology that works on a principle similar to radar or sonar. It is an active technology that sends and receives. It emits an inaudible high-frequency sound wave and evaluates the echo which is received back after bouncing around in the room. This allows the sensor to evaluate the whole room and can “look” over walls and obstructions to identify movement.
PLACEMENT GUIDELINES
CEILING AND WALL OCC SENSOR SENSING PATTERNS
CONTACT RATINGS: OSWS9P-120: 1000W Ballast, 800W Incandescent, 1⁄6HP at 120VAC. OSWS9P-277: 1800W Ballast at 277VAC. OSWS9PD & OSWS9PDM: 1000W Ballast, 800W Incandescent, 1⁄6HP at 120VAC, 1800W Ballast at 277VAC.
responsible
energy
CALIFORNIA Title 24
CEILING SENSOR
A Ceiling Sensor provides a 360° coverage pattern of up to 1200 square feet when using passive infrared only. When using dual technology the coverage pattern extends to over 2000 square feet. Barriers within the space that block line-of-sight to sensor detection will decrease coverage area when using passive infrared by itself, ultrasonic dual technology will allow the sensor to get around the obstructions.
SPECIFICATIONS
ASHRAE 90.1
APPLICATIONS
ADJUSTABLE TIME DELAY: 30 seconds - 30 minutes.
Offices and hotels Classrooms Conference rooms Lavatories Hallways
OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C). MOUNTING: Box mount.
FEATURES OSWS9P-120, OSWS9P-277 & OSWS9PD: OPERATION: Automatic ON and automatic OFF based on occupancy detection. OFF DELAY: Selectable from 30 seconds to 30 minutes. MANUAL OVERRIDE: Includes ON and OFF switch. EASY WIRING: No neutral required. Great for retrofit. OSWS9PD ALSO INCLUDES: SENSITIVITY ADJUSTMENT: For PIR range. DAYLIGHTING MODE: Adjustable level to keep lights OFF even when occupancy is sensed if adequate light exists in the room from windows or skylights.
ORDERING INFO CATALOG NO.
UPC CODE
DESCRIPTION
OUTPUT CONTACTS
OSWS9P-120
82077
PIR in-line wall switch
120VAC
OSWS9P-277
82078
PIR in-line wall switch
277VAC
OSWS9PD
82079
120/277VAC
OSWS9PDM
82080
PIR in-line wall switch with ambient light sensor PIR in-line wall switch manually activated
WIRING & COVERAGE DIAGRAMS Wall Mounting Box
OSWS9PDM - VACANCY SENSOR: OPERATION: Manual push button on and then automatic OFF.
LINE (Black)
OFF DELAY: Selectable from 30 seconds to 30 minutes.
LOAD (Red)
SENSITIVITY ADJUSTMENT: For PIR range. DAYLIGHTING MODE: Adjustable level to keep lights OFF even when occupancy is sensed if adequate light exists in the room from windows or skylights. MANUAL OVERRIDE: Includes ON and OFF switch.
120/277VAC
GND (Green)
Top and Side Coverage Pattern Diagrams
EASY WIRING: No neutral required.
35'
16' 180° Coverage 15°
4.0' 15° 35'
TORK 109
TORK 110
OSC15PLS
SPECIFICATIONS
PIR SENSOR, WITH AMBIENT LIGHT OVERRIDE, MULTI-VOLTAGE INTEGRAL POWERPACK, CELING MOUNTED OCCUPANCY SENSOR
VOLTAGE: 120 - 347VAC. ADJUSTABLE LIGHT LEVEL: 5FC - 200FC.
responsible
energy
CALIFORNIA Title 24 ASHRAE 90.1
ADJUSTABLE TIME DELAY: 30 seconds 30 minutes (DIP switch). TEST MODE: 5 seconds, upon initial power-up or DIP switch reset.
APPLICATIONS
PIR COVERAGE: 1200 sq. ft.
Offices and hotels Classrooms Conference rooms Lavatories Hallways
sensitivity adjustment: Full or 50% low (DIP switch). operating temperature: 32° to 131°F (0° to 55°C). mounting: Ceiling or box mount. contacts: SPST dry contacts.
FEATURES
contact ratings: 800W Incandescent, 1000W ballast at 120VAC. 1800W Ballast at 277VAC. 2200W Ballast at 347VAC.
OPERATION: Automatic ON and automatic OFF based on occupancy detection.
OSC12PL & OSC5PL
SPECIFICATIONS VOLTAGE: 24VDC.
PIR SENSOR CELING MOUNTING OCCUPANCY SENSORS
UPC CODE
INPUT SUPPLY
COVERAGE (FEET)
DESCRIPTION
OSC15PLS
82076
120-347VAC
1200
WHITE
WIRING & COVERAGE DIAGRAMS
OSC15PLS SENSOR
N
LOAD
WHITE (NEUTRAL) BLACK (LINE)
RED
RED
ADJUSTABLE LIGHT LEVEL: 10FC - 150FC.
Offices Classrooms Conference rooms Lavatories Hallways
ADJUSTABLE TIME DELAY: 5 seconds - 30 minutes (DIP switch). TEST MODE: 5 seconds, upon initial power-up or DIP switch reset. PIR COVERAGE: 1200 sq. ft.
OSC5PL / OCCUPANCY SENSOR ASSORTED SENSING PATTERNS OSC5PL / OCCUPANCY SENSOR ASSORTED SENSING PATTERNS
FEATURES
18ft
SENSITIVITY ADJUSTMENT: Full or 50% low (DIP switch).
18ft
MOUNTING: Ceiling or box mount.
OPERATION: Automatic ON and automatic OFF based on occupancy detection.
DAYLIGHTING MODE: Selectable to keeps lights off when occupancy is sensed if adequate light exists in the room from windows or skylights.
CATALOG NO.
POWER SUPPLY: TRP-U Power Pack (up to 6 units).
CALIFORNIA Title 24
APPLICATIONS
OFF DELAY: Selectable from 30 seconds to 30 minutes.
POWER SWITCHING: Built-in power pack for direct line voltage control.
energy
ASHRAE 90.1
OFF DELAY: Selectable from 30 seconds to 30 minutes.
ORDERING INFO
CURRENT CONSUMPTION: 9mA.
responsible
OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C).
ORDERING INFO
12ft COVERAGE (FEET)
12ft
ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time.
CATALOG NO.
UPC CODE
INPUT SUPPLY
WALK-THROUGH MODE: Selectable to turn lights OFF after only 3 minutes. If no activity is detected after 30 seconds of occupancy detection, lights turn OFF.
OSC5PL
82083
24VDC
500
White
OSC12PL
82081
24VDC
1200
White
TRP-U
82030
120/277VAC
DAYLIGHTING MODE: Selectable to keep lights OFF when occupancy is sensed if adequate light exists in the room from windows or skylights.
LCS115M
82082
DESCRIPTION
Power Pack Momentary Switch
COVERAGE DIAGRAMS
PRESENTATION MODE: Optional MANUAL OFF by an accessory wall switch (LCS115M). Sensor will keep lights OFF while movement in room is detected, then return to automatic ON after 5 minutes.
DIP SWITCH Sensitivity
Time Delay
1
50%
VACANCY MODE: Optional MANUAL ON by an accessory wall switch (LCS115M) and then automatic OFF.
100% Walk Through
3
Audible Alert
4
Enabled Visible Alert
Vacancy
6
Disabled Enabled
WARNING BEFORE OFF: Optional visual flash warning and/or audible beep warning one minute before turn OFF.
Enabled
20 Minutes 25 Minutes
Hold ON
30 Minutes
Disabled
OFF
ON
8
Disabled
15 Minutes
Enabled
7
Disabled
30 Seconds 5 Minutes 10 Minutes
5
Disabled
MANUAL OVERRIDE: Optional manual control by an accessory wall switch (LCS115M) for ON and OFF.
2
5 Sec/EcoSet
Factory Setting
9
Enabled
OSC5PL
OSC12PL
PLUG TERMINAL: Quick disconnect for sensor. POWER SWITCHING: Transformer relay power pack (TRP-U) required to power sensor and provides line voltage switching. (see page 116 for product information).
OCCUPANCY SENSORS TORK 111
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
22 6.7
11
7
3
3
7
11
TORK 112
OSC2OUP
DUAL TECHNOLOGY CELING MOUNTED PIR/ULTRASONIC OCCUPANCY SENSOR
SPECIFICATIONS VOLTAGE: 24VDC. energy
CALIFORNIA Title 24 ASHRAE 90.1
APPLICATIONS
PIR COVERAGE: 1500 sq. ft. (adjustable). SENSITIVITY ADJUSTMENT: Individual setting range for ultrasonic of 50% and PIR of 75%. ULTRASONIC OUTPUT: 32Hz MOUNTING: Ceiling or box mount.
OPERATION: Automatic ON and automatic OFF based on occupancy detection. OFF DELAY: Selectable from 8 to 40 minutes. ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time.
POWER SWITCHING: Transformer relay power pack (TRP-U) is required to power sensor and provide line voltage switching (see page 116 for product information).
ADJUSTABLE TIME DELAY: 8 - 40 minutes.
US COVERAGE: 2000 sq. ft. (adjustable).
FEATURES
TORK 113
VOLTAGE: 24VDC. responsible
energy
CALIFORNIA Title 24 ASHRAE 90.1
APPLICATIONS
HUMIDITY: 0 to 95% R.H. non-condensing for indoor use only.
OFF DELAY: Selectable from 8 to 40 minutes.
ORDERING INFO CATALOG NO.
UPC CODE
INPUT SUPPLY
COVERAGE (FEET)
DESCRIPTION
OSCS20UP
82075
24VDC
2000 ft US 1500 ft PIR
White
TRP-U
82030
120/277VAC
Power Pack
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
POWER SWITCHING: Transformer relay power pack (TRP-U) is required to power sensor and provide line voltage switching (see page 116 for product information).
ADJUSTABLE TIME DELAY: 8 - 40 minutes.
SENSITIVITY ADJUSTMENT: Manual setting range of 50%. ULTRASONIC OUTPUT: OSC5U: 40kHz OSC10U/OSC20U: 32kHz MOUNTING: Ceiling or box mount. OPERATING TEMPERATURE: 32° to 104°F (0° to 40°C). HUMIDITY: 0 to 95% R.H. non-condensing for indoor use only.
ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time. MOTION INDICATION: Green for ultrasonic motion. Indicator may be disabled.
POWER SUPPLY: TRP-U Power Pack (up to 4 units).
US COVERAGE: 2000 sq. ft. (adjustable).
FEATURES OPERATION: Automatic ON and automatic OFF based on occupancy detection.
CURRENT CONSUMPTION: 33mA.
TEST MODE: 8 seconds, upon initial power-up for 1 hour.
Offices and hotels Classrooms Conference rooms Lavatories Hallways
OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C).
COVERAGE DIAGRAMS
OCCUPANCY SENSORS
SPECIFICATIONS
ULTRASONIC, CEILING MOUNTING OCCUPANCY SENSORS
POWER SUPPLY: TRP-U Power Pack (up to 3 units).
TEST MODE: 8 seconds, upon initial power-up for 1 hour.
Offices and hotels Classrooms Conference rooms Lavatories Hallways
MOTION INDICATION: Red for infrared motion, Green for ultrasonic motion. Indicators may be disabled.
CURRENT CONSUMPTION: 33mA.
responsible
OSC SERIES
ORDERING INFO CATALOG NO.
UPC CODE
INPUT SUPPLY
COVERAGE (FEET)
DESCRIPTION
OSC5U
82072
24VDC
500 SQ FT
White
OSC10U
82073
24VDC
1000 SQ FT
White
OSC20U
82074
24VDC
2000 SQ FT
White
TRP-U
82030
120/277VAC
Power Pack
COVERAGE DIAGRAMS
TORK 114
ELS
TRP-U
SPECIFICATIONS
INDOOR LIGHT LEVEL ELECTRONIC CCUPANCY SENSOR
responsible
energy
VOLTAGE: 24VDC.
ASHRAE 90.1
LOAD REQUIREMENTS: Ballast 20amp @120/277VAC. Incandescent 20amp@120VAC. Motor 1HP @120/240VAC. Output 150mA @24VDC (with relay connected).
POWER SUPPLY: TRP-U Power Pack (up to 4 units). operating temperature: 50° to 104°F (10° to 40°C).
APPLICATIONS
mounting: Ceiling or box mount.
Offices Classrooms Conference rooms Hallways
LOW VOLTAGE INPUT: Control ON: 12 - 24VDC Hold ON: 12 - 24VDC Hold OFF: 12 - 24VDC
Power and switching for occupancy sensors Power and switching for SSA R-24 series BAS input compatible Demand shedding applications Device override to hold on Momentary switched override Low voltage 3-way wiring
FEATURES DAYLIGHTING CONTROL: Turns OFF when sufficient daylight present. ADJUSTABLE LIGHT LEVEL: 10FC - 250FC (DIP switch).
FEATURES
EASY MOUNTING: Low voltage Class 2 wiring allows recommended mounting about 3 feet from daylight sources.
OPERATION: Switches line voltage loads ON/OFF based on a contact closure from an occupancy sensor, AUTO OFF switch, or relay.
PRESET ON DELAY: 30 seconds prevents false triggering.
VOLTAGE: 120/230/277VAC, 50/60Hz.
CURRENT CONSUMPTION: 9mA.
CALIFORNIA Title 24
APPLICATIONS
ADJUSTABLE OFF DELAY: Set from 3 to 15 minutes.
SPECIFICATIONS
INTELLEGENT POWER PACK
ORDERING INFO CATALOG NO.
UPC CODE
INPUT SUPPLY
DESCRIPTION
ELS-1
82049
24VDC
Indoor Daylight Sensor
TRP-U
82030
120/277VAC
Power Pack
operating temperature: 32° to 131°F (0° to 55°C).
ORDERING INFO
INTELLEGENT INPUT: Three additional input wires: 1. Hold OFF for demand shed control. 2. Hold ON override of local devices such as sensors. 3. Momentary switch input for remote override.
CATALOG NO.
UPC CODE
INPUT SUPPLY
DESCRIPTION
TRP-U
82030
120/277VAC
Power Pack
MULTI-VOLTAGE: Tri-voltage input for flexibility.
LCS115M
82082
QUICK MOUNTING: Snaps into 1⁄2" box KO.
WIRING DIAGRAMS
MOUNTING: Box mount to 1⁄2" KO.
Momentary Switch
WIRING DIAGRAMS
ON 1 2 3 4 5 6 7
Power Pack 277V Model TRP2 or Power Pack 120V Model TRP1
New Extension Box
Existing Junction Box
TRP-U LOW VOLTAGE WIRING
New Cover With 1/2 K.O. Provision PHOTO SENSOR ORIENTATION ARROW UNDER IVORY COVER
PROGRAMMABLE 7-SECTION SLIDE SWITCH FOOT CANDLE SELECTION* +
1 2 3 4 56 FOR7
SLIDE
FOOT CANDLE
#1
10FC
Warehouse
#2
25FC
#3
50FC
#4
75FC
Corridors Machine equipment display showroom (such as automobile and farm equipment) LOBBY (such as airport waiting area). Classrooms, common office areas
#5
100FC
Drafting rooms
#6
150FC
Retail display areas
250FC
High critical areas, product sorting and grading, paint quality control.
#7
Bend Tabs After Inserting in K.O. Hole New Extension Box Only Used When Low Voltage Wiring Has to be Enclosed
*Slide only one switch to ON for selection, all other switches remain OFF.
OCCUPANCY SENSORS TORK 115
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 116
PLUG-IN TIMERS
400A SERIES
400D SERIES
INDOOR GENERAL PURPOSE 1875W MECHANICAL MULTIPLE ON/OFF TIMERS
INDOOR GENERAL PURPOSE 1800W DIGITAL PROGRAMMABLE ON/OFF TIMERS
NEW! responsible
energy
CALIFORNIA Title 24 ASHRAE 90.1
401A
APPLICATIONS
460D
APPLICATIONS 405A
Lamps, radios, televisions Appliances Automatically turn ON/OFF items in the home, gives the home a "lived in" look while away.
Lamps, radios, televisions Appliances NEW!
455D
Automatically turn ON/OFF items in the home, gives the home a "lived in" look while away.
402A
FEATURES
454D
NEW!
422A
FEATURES
457Z
REPEAT SCHEDULE: Daily.
REPEAT SCHEDULE: 7 day programming.
VARIABLE TIMING: Multiple ON/OFF times.
VARIABLE TIMING: 460D, 454D, 455D: Manual Daylight Savings adjustment. Random mode for lived-in look. Manual Override ON/OFF.
ON/OFF: Manual ON/TIMER switch. ENERGY SAVINGS: Works with CFLs and LED lamps.
403A
457Z: Turns ON at Sunset; turns OFF at Sunrise or other times; automatic DST adjustment; Random Mode for lived-in look; Manual Override ON/OFF. BACKUP: Battery back-up. ENERGY SAVINGS: Works with CFLs and LED lamps. ACCURACY: Digital accuracy to 1 minute.
ORDERING INFO CATALOG NO.
UPC CODE
401A
16001
402A
16002
403A
16013
405A
16014
422A
16019
ORDERING INFO
RATINGS
125 VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten 125VAC, 1⁄3HP
125VAC 15A, 1875W Resistive 125VAC 500W Tungsten 125VAC TV-4
NO. OF OUTLETS ( )
TYPE OF PLUG
DESCRIPTION
VARIABLE TIMING SEGMENTS
CATALOG NO.
UPC CODE
1
Polarized
Multiple ON/OFF Lighting Timer
15 minute
460D
16017
1
Grounded
Heavy Duty 24 hour Timer
15 minute
454D
16009
1
Polarized
Powerful & Compact Automatic Timer
30 minute
455D
16015
2
Grounded
Heavy Duty 15 AMP Automatic Timer
15 minute
1
Grounded
Heavy Duty 24 hour 15AMP Timer
30 minute
NOTE: " " = Indicates outlet location.
457Z
16016
RATINGS
120VAC, 15A, 1800W General Purpose 120VAC, 15A, 1800W Resistive 120VAC, 1000W Tungsten 120VAC, 1⁄3HP, TV-5 120VAC, 15A, 1800W General Purpose 120VAC, 15A, 1800W Resistive 120VAC, 960W Tungsten 120VAC, 1⁄3HP TV-5
NO. OF OUTLETS ( )
TYPE OF PLUG
DESCRIPTION
1
Polarized
Daily Programmable Digital Timer
24 ON/OFFs
VARIABLE TIMING SEGMENTS
1
Grounded
Daily Programmable Digital Timer
Different schedule for each day of the week.
2
Grounded
Daily Programmable Digital Timer
Multiple ON/OFFs 20 ON/OFFs
2
Grounded
Ultimate Plug-In 2-Outlet Timer
Different schedule for each day of the week. ON at Sunset OFF at Sunrise
NOTE: " " = Indicates outlet location.
PLUG-IN TIMERS TORK 119
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 120
600D SERIES
600A SERIES
OUTDOOR NEW! GENERAL PURPOSE 1875W 7 DAY DIGITIAL WITH PHOTOCELL, 7 DAY DIGITAL OUTDOOR TIMERS
OUTDOOR GENERAL PURPOSE 1875W MECHANICAL PLUG-IN PHOTOCELL COUNTDOWN TIMERS
APPLICATIONS
responsible
energy
CALIFORNIA Title 24 ASHRAE 90.1
Photocell
APPLICATIONS
Landscape or Christmas lighting Controls small pumps, fountains, motors
Landscape and Christmas lighting Control small pumps, fountains, motors, etc. Energy saving
601A 602A
621D & 631D
(621D without photocell)
611A
611D
FEATURES
FEATURES
REPEAT SCHEDULE: Daily.
REPEAT SCHEDULE: 7 day programming.
VARIABLE TIMING: Multiple ON/OFFs, Manual ON/ TIMER switch.
VARIABLE TIMING: Manual Daylight Savings adjustment. Random mode for lived-in look. Manual ON/TIMER switch. Multiple ON/OFF for each day of the week.
PHOTO TIMER: Two styles 652A - Dial setting. ON at dusk and OFF 2, 4, 6, or 8 hours later. 654A - Digital setting. ON dusk and OFF 1 to 9 hours later or at random times.
652A
BACKUP: Battery back-up. ACCURACY: Digital accuracy to 1 minute.
ENERGY SAVINGS: Works with CFLs and LED lamps.
654A
ORDERING INFO CATALOG NO.
UPC CODE
601A
16020
602A
16021
611A*
16022
652A
16026
654A
16025
RATINGS
125 VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten 125VAC, 1⁄2HP 125VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAc, 650W Tungsten 125VAC, 1⁄3HP, TV-5
NO. OF OUTLETS ( )
TYPE OF PLUG
DESCRIPTION
1
Grounded Mechanical Outdoor Timer, with18" cord
2
Grounded Mechanical Outdoor Timer, with18" cord
1
Wall Mountable Grounded Mechanical Outdoor Timer, with 24" cord
2
Grounded
Photocell Outdoor Timer with 6.5" cord
2
Grounded
Photocell Outdoor Timer with 6.5" cord
VARIABLE TIMING SEGMENTS
15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs Photo ON Dawn or timed OFF Photo ON Dawn or timed OFF
*611A: 1⁄3HP
PHOTOCELL: 611D and 631D have built-in photocell to always turn ON at dusk and OFF at dawn. Add a time OFF schedule
655D
655D Remote
WIRELESS REMOTE: 655D receives ON/OFF signal up to 80 feet away.
ORDERING INFO CATALOG NO.
UPC CODE
611D
16018
621D
16056
631D 655D*
RATINGS
NO. OF OUTLETS ( )
TYPE OF PLUG
1
Grounded
2
Grounded
16027
125 VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAC, 1000W Tungsten 125VAC, 8A Ballast 125VAC, 1⁄2HP
2
Grounded
16042
125VAC, 5A, 625W Resistive 125VAC, 600W Tungsten
2
Grounded
DESCRIPTION
Wall Mountable Photocell & 7 Day Digital 2-in-1 Timer, with 24" cord Wall Mountable, 7 Day Digital Timer, with 18" cord Wall Mountable Photocell & 7 Day Digital 2-in-1 Timer, with 18" cord Remote control indoor/outdoor receiver
VARIABLE TIMING SEGMENTS
Photo ON Dawn or timed OFF Multiple ON/OFFs for each day of the week Photo ON Dawn or timed OFF Handheld remote ON/OFF
* ETL listed for U.S. and Canada.
NOTE: " " = Indicates outlet location.
NOTE: " " = Indicates outlet location.
PLUG-IN TIMERS TORK 121
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 122
800 SERIES
NEW! OUTDOOR GENERAL PURPOSE 1875W MECHANICAL & DIGITAL STAKE TIMERS
APPLICATIONS Landscape and Christmas lighting Other outdoor lighting Energy saving 803B 806B
FEATURES REPEAT SCHEDULE: Mechanical timer 24 hours. Digital timer 7 day programming. 806D
MECHANICAL TIMING: Multiple ON/OFFs, Manual ON/ TIMER switch. DIGITAL TIMING: Manual ON/TIMER switch. Multiple ON/OFF for each day of the week. PHOTOCELL: 806D has optional built-in photocell to always turn ON at dusk and OFF at dawn or 1 to 12 hours later. ENERGY SAVINGS: Works with CFLs and LED lamps.
ORDERING INFO CATALOG NO.
UPC CODE
803B
16057
806B
16037
806D
16038
RATINGS
125VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten
125VAC, 15A, 1875W Resistive
NO. OF OUTLETS ( )
TYPE OF PLUG
3
Grounded
6
Grounded
6
Grounded
DESCRIPTION
VARIABLE TIMING SEGMENTS
Mechanical Outdoor Stake Timer, with 2' cord Mechanical Outdoor Stake Timer, with 2' cord. 3 timed outlets and 3 untimed.
15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs Multiple ON/OFFs for each Digital Outdoor Stake Timer, with 6' cord. 3 day of the week or Photo timed outlets and 3 untimed. ON and Dawn or 1-12 hours OFF.
NOTE: " " = Indicates outlet location.
PLUG-IN TIMERS TORK 123
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 124
TORKALERT
™
MECHANICAL STROBE HORNS
ALARM SOUNDS
MULTI-TONE ELECTRONIC HORNS
ALARM TONE
BELL HI-LO CHIME SINGLE STROKE BELL HORN 3 BEEPS, PAUSE SIREN SLOW WHOOP
24VDC &115VAC
APPLICATIONS
APPLICATIONS
TA880-N5
High performance for industrial signaling applications. Offers high sound output, low current draw and dependable operation. Strobes use xenon flashtube, ideal for maximum efficiency and reliability.
TA5508H-G1
ORDERING INFO CATALOG NO.
UPC CODE
INPUT VOLTAGE
INPUT CURRENT (AMPS)
dB @10 FEET
CANDELA
TA880-N5
96015
120VAC
0.115
96
15
ALARM: Penetrating mechanical sound.
TA5508H-G1
96071
24VDC
.059
strobe only
15/75
WIRING: Low current draw.
NOTE: TA880-N5 For outdoor use, unit must be mounted in a TA-WBBF outdoor backbox. See page 138 for ordering. TA5508H-G1 for indoor mounting only.
FEATURES
MOUNTING: 4" square surface mounting.
TA875-1G1
For indoor and outdoor use. Superior sound penetration for various room conditions. Screw terminals accept #12AWG.
MECHANICAL HORNS
FEATURES OPERATING TEMPERATURE: TA-MTS: -31˚F to +150˚F (-35˚C to +66˚C). DIMENSIONS AND MOUNTING: TA-MTS: 41⁄18”H x 41⁄8”W x 317⁄32”D Can be mounted on celing or wall. TA875-1G1: 43⁄4”H x 43⁄4”W x 13⁄8”D 1 gang, 2 gang or 4" square backbox.
TA875-1G1 24VDC HORN CURRENT (AMPS)
TA-MTS
ALARM TONE
HORN BELL HORN 2 CODE 3 HORN CODE 3 TONE SLOW WHOOP SIREN HI-LO
TYPICAL dB @10 FEET
0.020 0.025 0.028 0.026 0.023 0.023 0.040 0.040
91 96 93 93 97 97 95 96
TA-MTS 115VAC HORN AMPS @ 120VAC TYPICAL dB @10 FEET HIGH STANDARD HIGH STANDARD OUTPUT OUTPUT
0.050 0.041 0.050 0.050 0.042 0.050 0.045 0.042
0.042 0.039 0.040 0.042 0.040 0.042 0.041 0.039
85 82 85 82 79 85 85 82
82 75 79 75 75 82 82 79
ORDERING INFO CATALOG NO.
UPC CODE
INPUT VOLTAGE
DESCRIPTION
TA875-1G1
97641
20-31VDC, 24VDC
Multi-tone Electric Horn
TA-MTS
97674
115 VAC
Multi-tone Electric Horn
HEAVY DUTY BELLS
4", 6", 10" DIAMETERS AC VIBRATING BELLS
ORDERING INFO
APPLICATIONS
CATALOG NO.
Loud tone with typical decibel output of 103 dB. Low frequency resonation for strong penetration of noisy areas like boiler rooms, water pumping stations, elevators and air compressor rooms.
UPC CODE
INPUT VOLTAGE
INPUT CURRENT (AMPS)
APPLICATIONS
SURFACE TYPE
TA874-N5
96023
120VAC, 60Hz
0.070
TA874-N5R (Red)
97613
120VAC, 60Hz
0.070
TA875-G1
97687
24VDC
0.035
For indoor or outdoor applications. High sound output, durable and dependable performance. Ideal for schools and hopsitals.
ORDERING INFO INPUT VOLTAGE CURRENT (AMPS)
dB @ 10 FEET
CATALOG NO.
UPC CODE
SHELL SIZE
TA340-4G5
96001
4”
24VAC
0.320
81-90 Dawn Mist
TA340-4N5
96002
4”
120VAC
0.065
81-90 Dawn Mist
TA340-6G5
96003
6”
24VAC
0.320
81-95 Dawn Mist
TA340-6N5
96004
6”
120VAC
0.065
81-95 Dawn Mist
COLOR
WITH WEATHERPROOF BACKBOX TA-WBBF UL LISTED FOR OUTDOOR USE
FEATURES
TA876-N5
INPUT VOLTAGE: Wide input voltage ratings for compatibility with unregulated power supplies.
HOUSING: Steel, painted Dawn Mist. Resonant grill design for high sound output.
WIRING: Screw terminals for convenient IN/OUT wiring. Low current draw for minimizing power supply and wiring cost.
MOUNTING: To indoor box TA-BBSF or outdoor box TA-WBBF, see accessories page 13*.
NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.
96026
120VAC, 60Hz
0.070
FEATURES TERMINAL SIZE: #12 - 22 AWG.
TA340-10G5
96005
10”
24VAC
0.320
84-98 Dawn Mist
WIRING: Screw terminals permit fast IN/OUT field wiring.
TA434-4N5
98005
4"
120VAC
0.065
81-95
Red
HOUSING: Steel gong and cast aluminum. See page 138 for dimensional drawings.
TA434-6N5
97521
6”
120VAC
0.065
81-95
Red
TA434-10N5
96522
10”
120VAC
0.065
84-98
Red
NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.
TORK ALERT ™ TORK 127
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 128
LIGHT DUTY AND GENERAL PURPOSE BELLS & BUZZER
WEATHERPROOF MOTOR DRIVEN SIREN
DIMENSIONS FRONT VIEW
8-1/4"
Power wires 2 feet long
APPLICATIONS
APPLICATIONS Designed to operate on either bell ringing transformers or batteries. Non-adjustable sound.
TA725
(2) 9/32" mounting holes
Mount siren (hardware not included) 15-3/8"
FRONT VIEW
For industrial and outdoor use. Ideal for evacuation and warning systems.
TA740
6-7/8"
7-1/2" dia. (2) nuts, loosen to adjust siren direction. 8-1/4"
FEATURES ALARM: Bell ringing, non-adjustable sound. DIMENSIONS FOR TA725: 3" H x 21⁄2" W x 1" D. MOUNTING: Fully enclosed sturdy steel bases and covers. Base and cover snap together, no screws required.
ORDERING INFO
FEATURES
CATALOG NO.
UPC CODE
SWITCH
VAC
VDC
AMPS
dB
TA740
96228
21⁄2” Gong
8-16
3-6
1
76 @ 10'
TA744
96230
4" Gong
8-16
3-6
1
78 @ 10'
TA725
96226
Buzzer
8-16
3-6
1
88 @ 3'
ORDERING INFO
MOUNTING: Fully enclosed sturdy steel bases.
Junction box & (2) wire nuts (not furnished)
ORDERING INFO CATALOG NO.
UPC CODE
INPUT VOLTAGE
dB @10 FEET
AMPS
VA
TA315-1N5
96599
120VAC/DC
117
2.5
300
APPLICATIONS
Powerful and loud, pleasant sounding push-button chimes. Ideal for homes, apartments and offices.
ALARM: Chime.
HOUSING: Red enamel paint over heavy gauge aluminum housing. Fully enclosed motor. 180° swivel and adjustable direction.
Siren power wires
(2) 9/32" mounting holes
PULL-DOWN STATION
APPLICATIONS
INPUT: 16V, 10VA, 120VAC.
1/2" conduit (not furnished) 6-7/8"
MANUAL FIRE ALARM
CHIMES & CHIME KITS
FEATURES
Power wires 2 feet long
INPUT VOLTAGE: 120AC & DC, 60Hz. ALARM: Loud, distinctive tone. Designed to be effective over standard horns or bells.
8-1/2" dia.
1/2" conduit connector
CATALOG NO.
UPC CODE
TAC212WS
96064
TAC212WL
96054
TAC210W
96052
DESCRIPTION
16VAC Chime + Push Button clip for Stucco + 10VA Transformer 16VAC Chime + 2 Push-buttons + 10VA Transformer 16VAC Chime
DIMENSIONS
73⁄16”L x 4”W x 2”D 71⁄4”L x 43⁄4”W x 21⁄2”D 71⁄4”L x 43⁄4”W x 21⁄2”D
Designed for indoor use. Ideal for schools, hospitals, industrial plants, warehouses and retail stores. Key required to close and reset device. Meets requirements, BSA, MEA, CA and UL. FEATURES ALARM: Loud, distinctive tone. Designed to be compatible with any control panel to initiate local alarm signals, trip municipal fire alarm box and start fire pumps.
ORDERING INFO CATALOG NO.
UPC CODE
SWITCH
VOLTS
AMPS
TA270A
96521
SPST, NO
30V AC/DC
1
MOUNTING: Sturdy metal construction, mounts to a standard single gang electrical box.
TORK ALERT ™ TORK 129
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 130
TELEPHONE RELAY
TELEPHONE STROBE
APPLICATIONS
APPLICATIONS For single-line analog phone lines. Emits a high intesity flashing light when the telephone rings. Ideal for alerting the hearing impaired, high ambient noise environments and quiet zones. ADA compliant.
This device activates appliances when a telephone ring voltage is detected. For indoor and outdoor use with horns, bells or strobes. Recommended use where ambient noise levels are high. FCC approved.
ORDERING INFO
FEATURES PLUG: RJ-11C connection. TA-B-KHD-120VAC, includes 120VAC power cord.
RINGER PEAK EQUIVALENCE CANDLEPOWER
CATALOG NO.
UPC CODE
INPUT TELEPHONE RING VOLTAGE
POWER
TA-B-KHD-120VAC
97101
45-130V, 20-30Hz
120VAC
0.4
50-130V, 20-30Hz
Analog line ring voltage
1.5
TA-B-KHD-1000-PP
97102
ORDERING INFO
FEATURES
CATALOG NO.
UPC CODE
INPUT TELEPHONE RING VOLTAGE
AC INPUT VOLTAGE
RINGER EQUIVALENCE
PEAK CANDLEPOWER
70,000
INPUT: Accepts RJ-11C phone plug.
TA-B-8332
97100
39-150V/20-30Hz
WIRING: Hard wire connections, for analog phone lines.
Up to 115VDC-500MA
0.6
8,000
115VAC-5A, 230VAC-2A
MOUNTING: Easily mounts to interior surfaces, for indoor use.
MOUNTING: Weatherproof, indoor and outdoor, includes mounting bracket.
TELEPHONE HORN
WALL CLOCKS QUARTZ & ELECTRIC
ORDERING INFO QUARTZ CLOCK
APPLICATIONS
APPLICATIONS High quality compact signaling device. For indoor use. Easily connects to phone systems and enables locations with moderate to high ambient noise to have a loud telephone alert. FCC approved.
Each model meets United States Government Specifications. All Clocks provide second hand for accurate timing. ORDERING INFO
FEATURES ALARM: Adjustable tone and volume.
FEATURES
CATALOG NO.
UPC CODE
INPUT TELEPHONE RING VOLTAGE
dB @3 FEET
RINGER EQUIVALENCE
TA-B-KHS-1000-PP
97103
50-130V, 20-30Hz
90
0.8
PLUG: RJ-11C modular connection. MOUNTING: Grey enclosure. For indoor use, surface mountable.
QUARTZ Accurate to one minute per year. Low power consumption for long battery life. Uses AA battery (not supplied). ELECTRIC 110VAC, 60 Hz synchronous motor. 66 inch line cord and plug. Does not require grounding. MOUNTING: Concealed mounting brackets allow for simple, neat placement on walls.
CATALOG NO.
UPC CODE
TYPE
SIZE
FRAME COLOR
TA1886 G
96156
QUARTZ
8”
Grey
TA1886 B
96155
QUARTZ
8”
Brown
TA1887 G
96159
QUARTZ
12”
Grey
TA1887 B
96157
QUARTZ
12”
Brown
TA1887 BK
96158
QUARTZ
12”
Black
ELECTRIC CLOCK CATALOG NO.
UPC CODE
TYPE
SIZE
FRAME COLOR
TA1880 G
96152
ELECTRIC
8”
Grey
TA1880 B
96151
ELECTRIC
8”
Brown
TA1882 G
96154
ELECTRIC
12”
Grey
TA1882 B
96153
ELECTRIC
12”
Brown
TORK ALERT ™ TORK 131
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 132
PUSH-BUTTONS ILLUMINATED, NON-ILLUMINATED & WEATHERPROOF
ELECTRIC DOOR OPENERS REMOTE CONTROL & CONTACT DEVICES
DIMENSIONS TA1786B Only 1 3/8" (34mm)
2-3/8" DIA.
1-13/16" BETWEEN CL
2 13/32" (61mm)
MOUNTING HOLES ON MODEL TA1786B and TA1786CB
MODEL TA1786CB
For unlocking or locking metal or wooden doors using low voltage wiring. For AC, use TA591 or TA592 transformer.
MORTISE TYPE REMOTE OPENER
Reversible for right or left hand door. Use with mortise entrance locks having a latch bolt with up to 1⁄2" width and throw. Dimensional drawings available on page 138. DEVICE
CATALOG NO.
UPC CODE
VOLTS
AMPS
For outdoor use to activate low voltage bells, buzzers, horns or any other audible signal. Ideal for factory doors, receiving departments, small office buildings, limited access retail stores and private homes.
BUTTON
For activating a variety of signals, ideal for limiting space applications. Self-insulating and can be mounted in any direction. All units include companion magnet. Dimensions: 23⁄16”L x 1⁄2”W x 1⁄2”D UPC CODE
DESCRIPTION
TA60
96975
Circuit closed with magnet engaged
TA61
96976
Make & break NO and NC
TA62
96977
Circuit open with magnet engaged
VOLTS
24VAC 12VDC
TA09
96960
8-16VAC 3-6VDC
.95-1.75 1.25-1.80
AMPS MAX.
TA154
.5
96962
16VAC 3-6VDC
BUTTON
Signals automatically with the opening and closing of doors, windows and transoms. Operates from pressure in any direction. Non-tilt, non-jamming design. Fits 3⁄4" hole; no need to mortise. DEVICE
CATALOG NO.
UPC CODE
DESCRIPTION
TA44
96995
Normally closed Push to open
TA45
96996
Normally open Push to close
TA46
Momentary contact 96997 Push to make & break
VOLTS
AMPS MAX.
CATALOG NO.
Reversible for right or left hand door. Standard surface type used with lock latches with up to 5⁄8" width and throw. 6" wire leads. Dimensional drawings available on page 138. CATALOG NO.
UPC CODE
TA603L
2
ELECTRIC DOOR SWITCH
TA152
96961
UPC CODE
DESCRIPTION
INPUT VOLTAGE
TA1786B
96090
Without conduit backplate
TA1786CB
96091
With conduit backplate
Momentary Contacts 4 amps AC/DC @ 12V 4 amps AC, 2 amps DC @ 24V 2 amps AC 1 amp DC @48V
NON-ILLUMINATED PUSH-BUTTONS, UP TO 24VAC
COLOR
96035
Gold
CATALOG NO.
UPC CODE
COLOR
SIZE
TA600
96041
Polished Brass
21⁄4” (diameter)
TA603
96044
Polished Brass
13⁄4” (diameter)
TA631
96088
White
23⁄4 x 7⁄8"
TA635
96047
Ivory, black bar
23⁄4 x 7⁄8"
TA666BK
96048
Black, ivory bar
23⁄4 x 23⁄4
TA602
96043
Polished Brass
13⁄8 x 51⁄4 ”
TA601
96042
Sprayed Brass
2 x 29⁄16 ”
5⁄8"
TA620*
96045
Chrome
5⁄8” (diameter)
5⁄8"
TA620B*
96046
Brass
5⁄8” (diameter)
SIZE
13⁄4"
(diameter)
VOLTS
TA631L 12-24V AC/DC
UPC CODE
RIM TYPE REMOTE OPENER
DEVICE
CATALOG NO.
.95-1.75 1.25-1.80
ILLUMINATED PUSH-BUTTONS, UP TO 16VAC
DOOR/WINDOW CONTACTS, ROLLING BALL TYPE
MODEL TA1786B
WEATHERPROOF PUSH-BUTTONS / SOLID CAST BRASS
MAGNETIC SWITCH CONTACTS CATALOG NO.
2 13/32" (61mm)
APPLICATIONS
APPLICATIONS
DEVICE
1 3/16" (30mm)
96089
White
23⁄4 x 7⁄8"
8-16VAC, 3-6VDC
DOOR TRIP SWITCH
TA656B
96039
Gold
TA215LB
96031
Brass
TA620L*
96037
Chrome
TA620LB*
96038
Brass
15⁄16
x 23⁄4”
BUTTON
For turning lights/signals on or off when doors are opened or closed. Ideal for closets, dark rooms, Signals automatically as door is openend. Commonly used on store doors to announce storage areas of walk-in refrigeration. Rust resistant steel case with 4 knockouts, antique brass plate. entrance of customers. Mounts on top of door frame. Solid cast brass. Size: 3 x 15⁄8“ Box dimensions: 11⁄4"W x 3 7⁄8"H x 2”D. Plate dimensions: 11⁄4”W DEVICE
CATALOG NO.
UPC CODE
DESCRIPTION
VOLTS
AMPS MAX.
TA502
96964
Light ON when door is open
125VAC 250VAC
6 3
DEVICE
CATALOG NO.
TA236 TA503
96965
Light OFF when door is open
125VAC 250VAC
6 3
UPC CODE
96963
VOLTS
12-24VAC
AMPS MAX.
2
11⁄4 x 2”
(diameter) (diameter)
*Stainless steel plate to fit TA620 models: Order TA 147-1
TORK ALERT ™ TORK 133
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 134
WARNING LIGHTS INDUSTRIAL UNITS
WARNING LIGHTS VEHICULAR UNITS
ORDERING INFO
APPLICATIONS
COLOR
LETTER TO REPLACE "*"
Red Amber Clear Blue
R A C B
conduit mounting. Full selection of dome colors, see "Ordering Info". For outdoor use. All units must be mounted vertically with base at bottom.
DESCRIPTION
TA52*N5 – COMPACT ROTATING BEACON DEVICE
117VAC 117VAC
TA53*E1 – ROTATING BEACON
Light intensifying reflector rotates arounf a low current 25 watt bulb. Bayonet socket for easy lamp replacement. Ideal for restricted or dangerous areas.
VOLTS AMPS
90 FPM Corrosion resistant/Outdoor use Glass filled polypropylene housing Acrylic dome TA47AN5 96161 Tamper resistant dome clamps Nominal current draw TA47AR5 96162 91⁄2"H x 81⁄2” diameter
TA47RN5 96061
CATALOG UPC NO. CODE
TA52RN5 96063 .9
TA52AN5 96163
240VAC, 60Hz
TA52BN5 96263
DESCRIPTION
VOLTS AMPS
DEVICE
CATALOG UPC NO. CODE
TA53RE1 96083
80-90 FPM 360˚ rotation Dependable belt & turntable design 117VAC .21 Acrylic dome Nominal current draw 61⁄2”H x 55⁄8” diameter
TA53AE1 96183 TA53AF1 96185
Solid state circuitry in a low profile design. No moving parts means less Maintenance!
TA93-2AN5 97623 TA93-2CN5 96968 TA93-2BN5 97624
Single point shock-mounting. Ideal for use on security or service vehicles.
DESCRIPTION
VOLTS
90-100 FPM Dependable belt & turntable design 25 watt lamp Acrylic Dome Nominal current draw 71⁄2”H x 6” diameter
12VDC
DEVICE
CATALOG UPC NO. CODE
DESCRIPTION
VOLTS
75 FPM, 12 watt lamp 12VDC Quiet belt-drive motor. Teardrop design fits under windshields. Includes glare shield, velcro tape TA54RE1 96087 41⁄2”H x 71⁄2” diameter
TA54AE1 96187
36VDC 24VDC
TA371L*N5 – ROTATING SEALED TWIN BEAMS
TA93-2*N5 – MIDI-STROBE
TA93-2RN5 99622
R A
TA54*E1 – PORTABLE, MAGNETIC, ROTATING BEACON
Single point shock-mounting. Ideal for use on security or service vehicles.
TA53AG1 96184
DEVICE
Red Amber
conduit mounting. Full selection of dome colors, see "Ordering Info". For outdoor use. All units must be mounted vertically with base at bottom.
TA47*N5 / TA47*R5 – ALL PURPOSE 360° BEACON
CATALOG UPC NO. CODE
LETTER TO REPLACE "*"
1⁄2"
Large parabolic reflector rotates around a 100 wall bulb. Long range beam. Use to indicate equipment malfunctions, security intrusion, etc. CATALOG UPC NO. CODE
COLOR
APPLICATIONS
1⁄2"
DEVICE
ORDERING INFO
DESCRIPTION
Heavy Duty, double sealed beam, revolving light with 30 watt lamps. Each 35,000 CP bulb provides long range visibility.
VOLTS AMPS
70-80 FPM Solid state electronic circuitry High output 3-4 watt, 3.6 joules Vertically mounted flash tube 117VAC .04 Snap out socket base for 360˚ Fresnel dome optics Nominal current draw 6 1⁄2”H x 5 1⁄8” diameter
DEVICE
CATALOG UPC NO. CODE
TA371LRN5 96500
DESCRIPTION
TA131D*N5 / TA131D*U1 – DOUBLE FLASH SUPER STROBE
VOLTS AMPS
80-90 FPM 117 VAC Lexan® dome Quiet belt drive motor Anodized aluminum housing with polished aluminum, non-tarnishing base Snap lock retaining ring for quick & economical changeout 91⁄2”H x 8 1⁄2” diameter
.8
Ideal for industrial applications requiring extremely high visibility. One model covers all popular mounting methods: 1⁄2" pipe, surface, flange, electrical box. DEVICE
CATALOG UPC NO. CODE
TA131DRN5 96510 TA131DAN5 96610 TA131DRU1 96511 TA131DAU1 97611
TA94*N5 – ELECTRONIC STROBE
DESCRIPTION
VOLTS AMPS
120VAC 60 FPM, 7.5 JPF High intensity 85,000 peak CP Flashtube Rated at 7000-8000 hrs. Durable Lexan® housing 10.55”H x 71⁄4” diameter
.2
TA879 – VEHICULAR BACKUP ALARM
Solid state electronic unit. Helps to comply with OSHA and State regulations. Makes distinctive noise, ideal for extreme variations in background noise DEVICE
CATALOG UPC NO. CODE
TA879
96102
DESCRIPTION
VOLTS
2 sound levels 97 or 87 dB +/- dB at 4ft Multi-voltage Water-resistant housing
12 to 48VDC
31.0VDC
High intensity strobe tube with inner fluted lens for maximum brilliance. No moving parts makes it immune to shock and vibration. Ideal for security alert. DEVICE
CATALOG UPC NO. CODE
DESCRIPTION
VOLTS AMPS
70-80 FPM Solid state electronic circuitry High output 3-4 watt, 3.6 joules Acrylic dome TA94AN5 97627 117VAC .04 Glass filled polypropylene housing Suitable for outdoor use TA94BN5 97628 91⁄2”H x 81⁄2” diameter TA94RN5 97626
NOTE: "FPM" = Flashes per minute "JPF" = Joules per flash For replacement parts and accessories, see page 138.
TORK ALERT ™ TORK 135
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 136
ACCESSORIES, REPLACEMENT PARTS & DIMENSIONS
POWER SUPPLY UNITS 24 VDC UNITS
TA640 TA606
Red Amber Clear Blue Green White
Units provide power to multiple signaling devices depending on requirements.
TA606 Regulated and filtered 24VDC up to 600mA. Easy to use screw terminals, accepts #16-24AWG. No conduit is required for installation.
RIPPLE OUTPUT CURRENT REGULATION VOLTAGE
CATALOG NO.
UPC CODE
INPUT VOLTAGE
OUTPUT VOLTAGE
TA606
96109
117VAC
24VDC
600mA
TA640
96110
115VAC
24VDC
4A
+/-5%
10mVRMS
TA640 Dual output unit, each providing 2 Amps fo current. If connected in parallel, will provide up to 4Amps. Circuit breaker provides input protection.
TRANSFORMERS
UNIT
ORDERING INFO UPC CODE
TYPE
TA590
96104
Bell
TA591
96105
Chime
VOLTS-AMPS PRIMARY SECONDARY (VA) VOLTAGE VOLTAGE
5 10
120 120
10 16
Hz
60 60
TA592
96106
Tri-Volt
10-10-20
120
8-16-24
50/60
TA598
96602
Tri-Volt
20-30-30
120
8-16-24
60
TA599 TA1245Y-50 TA1245Y-75
96108 96166 96167
Heavy Duty Heavy Duty Heavy Duty
96971
Acrylic Dome – Amber
TA-M1
96138
12VDC Motor
TA53, TA54
TA-B1
96114
Small Drive Belts
TA53, TA54
TA-B2
96115
Large Drive Belts
TA371L
TA-B3
96116
Drive Belts
TA53, TA54
TA-L3
96129
12VDC Bulb
TA53
TA-L4
96130
24VDC Bulb
TA93-2
TA-L6-2
96982
110VAC Xenon Flash Tube
TA52
TA-L8
96134
110VAC Bulb
TA47
TA-L9
96135
110VAC Bulb
TA-L10
96136
110VAC Xenon Flash Tube
TA-L10-1 96981
110VAC Xenon Flash Tube
40 50VA 75VA
120 120/208/240 120/208/240
24 24 24
60 60 60
TA-L12
97625
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
WIRING DIAGRAMS
1/2"
2-7/8"
1-13/16"
TA874 Series
TA-BBSF 97694
TA874 Series
TA-WBBF 97692
Backbox – 4" painted Dawn Mist Weatherproof Backbox – .5" KOs 4" painted Dawn Mist Semi-Flush plate – Dawn Mist
3"
3-1/2"
TA-ADR
96111
Acrylic Dome – Red
TA47, TA94
TA-ADA
96311
Acrylic Dome – Amber
TA47, TA94
TA-ADB
96411
Acrylic Dome – Blue
TA52, TA53
TA-D5B
96419
Acrylic Dome – Blue
WIRE LEADS 11/16"
3/32" 1-3/8"
TA-D6A
96320
Dome – Amber
TA54
TA-D6C
96422
Dome – Clear
TA93, TA94
TA-D7R
96121
Fresnal Dome – Red
TA93, TA94
TA-D7A
96321
Fresnal Dome – Amber
TA-D7B
96421
Fresnal Dome – Blue
TA131D
TA-D8R
96970
4-1/16"
15/16" 3/16" 7/16"
HEAVY DUTY BELLS 6” 10" DIA.
10”
6" 4-1/16" 3-3/8"
3-3/8"
10" DIA.
4-1/16"
3-3/8" 3-3/8" 4-1/16"
3-3/8"
3-1/4" .173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES
3-3/8" 4-1/16"
3-3/8"
.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES
4 1/16” 3-3/8"
3-3/8"
3-1/4"
4-1/16"
.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES
.173 DIA. CSK 80 ° TO 82° 6" 11/32" DIA. – 4 PLACES TO
4-1/16" 3-3/8"
Acrylic Dome – Red
.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES 3-1/4"
3-3/8"4-1/16"
3-1/4"
3-1/4"
3-1/4"
.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES
4” 3-3/8"
10" DIA.
6"
4-1/16"
4-1/16" 3-3/8"
4-1/16"
Fresnal Dome – Clear
TA93, TA94
5/8"
27/32" 23/32"
Dome – Red
TA54
CL
1-9/16"
No. 6 FLAT HEAD WOOD SCREW
Semi-Flush plate – Red
TA47, TA94
3/32"
7/16"
CL
TA154
1/4" 15/16"
7/32"
1/8"
5/8" 1-1/4"
Replacement switcH
96621
1-1/4"
110VAC Bulb
4-1/16"
TORK 137
NO. 8 FLAT HEAD WOOD SCREW
TA503SW 96969
TA-D7C
1"
CL
TA503
TA93, TA94
5/8" 1-3/4"
5-7/8"
Replacement switch
96120
1-9/16"
3-5/8"
TA502SW 96966
TA-D6R
3/4"
5-3/8"
TA502
TA54
3/8"
1-3/8"
Backbox
TA-BBSF, TA-WBBF TA-SFPFR 97697
11/32"
2-3/4"
3/32"
TA502-BX 96967
97707
1/8"
1/16"
TA09
TA502
TA-BBSF, TA-WBBF TA-SFPF
1/16"
9/16"
DESCRIPTION
3-3/8"
TORK ALERT ™
11/16"
No. 6 MOUNTING SCREWS (3)
1/2"
CL
TA-D8A
TA94
APPLICATIONS
CATALOG UPC NO. CODE
WIRE LEADS
CL 1-3/8"
2-1/8"
< Full selection of dome colors. To designate color, place desired letter in place of " * "
TA53
TA-94
CATALOG NO.
3-5/16"
1-3/16"
TA131D
TA371L
Engineered to ensure long use on bells, buzzers and chimes.
9/16"
TA152
ORDERING INFO
ORDERING INFO FEATURES
REMOTE CONTROL DOOR OPENERS
15/16"
APPLICATIONS
LETTER TO REPLACE "*" R A C B G W
COLOR
DIMENSIONS
4-1/16"
2-7/8"
.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES
TORK 138
POOL&SPA CONTROLS
PP PANEL SERIES POOL AND SPA PANELS WITH TIME SWTICHES
APPLICATIONS Pumps Swimming pools Fountains Ponds
LISTED POOL/SPA CONTROL PANEL 3NZM
PP-100R-P4
ORDERING INFO
PP-20R-2P4
CONTROL INPUT
CONTROL #2
120VAC
N/A
Rated for 15A, 1⁄2HP @ 120VAC
53011
Mechanical 24 hour timer Digital 7 day timer
120VAC
N/A
Rated for 15A, 1⁄2HP @ 120VAC
PP-20R
94015
N/A
120/240VAC
N/A
Panel only. Add controls from page 147 and 148.
PP-20R-P1
53000
P1101-M
120VAC
N/A
PP-20R-P4
53001
P1104-M
240VAC
N/A
DEVICE MOUNTING: Provision for mounting one or two devices in any combination accepts toggle, GFCI, X-10 and UPB type devices in, PP-100R and PP-125R enclosures.
PP-20R-2P1
53002
P1101-2M
120VAC
PP-20R-2P4
53003
P1104-2M
240 VAC
Included with control #1 mechanism Included with control #1 mechanism
PP-100R
94016
N/A
120/240VAC
TRANSFORMER: Select panels include 120V input: 100 watt with output 12V/13V or 300 watt with output 12V/13V/14V.
PP-100R-P4
53004
P1104-M
240VAC
PP-100R-P4P1
53005
P1104-M
240VAC
P1101-M
120VAC
PP-100R-2P4
53006
P1104-M
240VAC
P1104-M
240VAC
PP-100R-P4P4FM
53009
P1104-M
240VAC
P1104FM-M
240VAC
PP-125R
94017
N/A
120/240VAC
PP-125R-P4
53007
P1104-M
240VAC
PP-125-2P4
53008
P1104-M
240VAC
P1104-M
240VAC
PP-125R-P4-100X
94018
P1104-M
240VAC
PP-125R-P4-300X
94019
P1104-M
240VAC
PP-10R-M-GFCI
FEATURES COMBINATION PANEL: The PP panel series provides a flexible platform to create a custom pool and spa control at an off the shelf price. Start with a blank panel and addtimers, freeze controls, circuit breakers, switches and outlets for a custom installation. Or select a pre-assembled timer/panel available in many popular combinations. PP-10R: 15 amp timed GFCI protected outlet with additional GFCI outlet. PP-20R: 20 amp load center 120-240V, 1/2 circuit breaker base. PP-100R: 100 amp load center 120-240V, 5/10 circuit breaker base. PP-125R: 125 amp load center 120-240V, 8/16 circuit breaker base. CONTROLS: Freeze protection or mechanical and digital timers are all available with unique features not found elsewhere in the industry. Find specification details on pages 147 and 148. BREAKERS: Listed for Cutler Hammer (BR), GE (THQL), Murray/Siemens (MP) and Square D (HOM) (not included).
REVERSIBLE DOOR: Easy-Hinge patented removable and reversible door. Change from left to right opening. Solves installation issues in the field. WHILE-IN-USE COMPARTMENT: Inside mounting for two devices with cord exit.
COMPACT 2-IN-1: PP-20R-2P1 and PP-20R-2P4 includes two timers in a compact housing. Interlock switch allows second timer to turn ON only if first timer is in operation. ENCLOSURE: Metal NEMA 3R with lockable hasp. See page 153 for dimensions.
NOTE: " " = Indicates freeze protection.
POOL & SPA CONTROLS TORK 141
PP-125R-P4-100X
PP-125R-P4
PP-20R-P4
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
CATALOG NO.
UPC CODE
PP-10R-M-GFCI
53010
PP-10R-E-GFCI
CONTROL #1
CONTROL INPUT
ADDITIONAL INFORMATION
120VAC
Two timers design 50A panel
240VAC
Two timers design 60A panel Panel only. Add controls from page 147 and 148. Add another control from page 147 and 148.
Timer 2 includes Fireman Switch Panel only. Add controls from page 147 and 148. Add another control from page 147 and 148.
Includes 100 watt Low Voltage Transformer Includes 300 watt Low Voltage Transformer
TORK 142
PFP SERIES
1100 SERIES
POOL FREEZE PROTECTION SWIMMING POOL TIME SWITCHES
SPECIFICATIONS
SAME ON/OFF TIMES EACH DAY SWIMMING POOL TIME SWITCHES
INPUT VOLTAGE: 120 or 208-277VAC, 60Hz (varies by model). TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40° to 165°F (-40° to +74°C).
APPLICATIONS
APPLICATIONS
POWER CONSUMPTION: 3 watt max.
Pool pumps Heaters Lighting
Pumps Swimming pools Fountains Ponds
ENCLOSURE: Lockable hasp. Type varies by model. See page 153 for dimensions and additional enclosure information.
FEATURES SCHEDULING: Minimum ON setting is 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes.
FEATURES FREEZE PROTECTION ONLY: Sensor turns on load when outdoor air temperature drops to user settable level between 33°F to 42°F. Moving water prevents costly freeze damage. TIMERS WITH FREEZE PROTECTION: Control loads with mechanical or digital timer with regular on and off schedule. Built-in temperature sensor forces load on if outdoor air temperature drops to user settable level between 33°F to 42°F. COMBINATION PANEL Combination of timers, freeze protection, breaker base, and device mountings. PP-20R: 20 amp load center 120-240V, 1⁄2 circuit breaker base. PP-100R: 100 amp load center 120-240V, 5⁄10 circuit breaker base.
ORDERING INFO CATALOG NO.
UPC CODE
CONTROL
CONTROL INPUT
NOTES
CATALOG NO.
UPC CODE
PFP2
94035
PFP2-M
240VAC
Freeze protection only
1101
10011
PFP3
94036
PFP3-M
120/240 w/neutral
Freeze protection only
1101-M-IAP
10052
PFP1102
94037
PFP1102-M
240VAC
1104
10014
PFP1103
94038
PFP1103-M
120/240 w/neutral
1104-N
10042
PFPEW1102
94039
PFPEW1102-M
240VAC
1104-O
10017
PFPEW1103
94040
PFPEW1103-M
120/240 w/neutral
1104-M-IAP
10051
PP-20R-F2
94033
PFP1102-M
240VAC
1101FM-N
10043
94034
PFP1102-M & P1104FM-M
240VAC
Freeze protection with timer Freeze protection with timer Freeze protection with Digital timer Freeze protection with Digital timer Freeze protection with timer Timer 2 includes Fireman Switch
1104FM-N
10044
120/240VAC
Thermostat accessory
1101FM-M
10043
1104FM-M
10044
1101D
10028
1104D
10029
1104DF
10032
PP-100R-F2F4FM PFPT
94028
BEAKERS: Listed for Cutler Hammer (BR), GE (THQL), Murray/Siemens (MP) and Square D (HOM) (not included). WHILE-IN-USE COMPARTMENT: Inside mounting for two devices with cord exit.
Replacement Trippers
DEVICE MOUNTING: Provision for mounting one or two devices in any combination accepts toggle, GFCI, X-10 and UPB type devices.
POOL & SPA CONTROLS TORK 143
NOTE: "
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
CONTACT RATINGS
ORDERING INFO
" = Indicates Freeze Protection.
Replacement Motor
INPUT SUPPLY (VAC) 60Hz
OUTPUT CONTACTS
ENCLOSURE TYPE
Metal Indoor NEMA 1 Mechanism and 120 SPST mounting plate Metal Indoor 208-277 DPST NEMA 1 ® Indoor/Outdoor Noryl 208-277 DPST NEMA 3R Metal Indoor/Outdoor 208-277 DPST NEMA 3 Mechanism and 240 DPST mounting plate Noryl® Indoor/Outdoor NEMA 120 SPST 3R with fireman switch ® Indoor/Outdoor NEMA Noryl 208-277 DPST 3R with fireman switch Mechanism with fireman 120 SPST switch Mechanism with fireman 208-277 DPST switch Two 1101 Metal Indoor/Outdoor 120 SPST each NEMA 3R Two 1104 Metal Indoor/Outdoor 208-277 DPST each NEMA 3R One 1104 Metal Indoor/Outdoor NEMA 208-277 One 1104FM 3R Order #P47 for a pair of ON/OFF trippers Order #PF48 for a pair of ON/OFF trippers for 1100FM series 120
SPST
TYPE
VOLTAGE
CONTACT RATING
40A
Resistive
120-277VAC single phase 120-277VAC single phase
Tungsten
120VAC
40A
Inductive
120, 277VAC single phase
20A
Pilot Duty
120-277VAC
1000VA
Motor
120VAC 240VAC
2HP 5HP
General Purpose
40A
#101 (120V) & #201 (208-277V)
TORK 144
DW200B TIMER
CONTACT RATINGS
SPECIFICATIONS
TWO SPEED PUMP CONTROL TIME SWITCH
TYPE
TIMING ACCURACY: Line Frequency. INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz.
Two speed pumps SVRS device
30A
30A
Ballast
OPERATING TEMPERATURE: -40°F to 158°F (-40°C to +70°C).
120VAC 277VAC
30A 20A
10A 10A
Tungsten
120-277VAC
15A
2A
POWER CONSUMPTION: 5VA max.
Pilot Duty
120-277VAC
720VA
720VA
ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R is standard with lockable hasp. See page 153 for enclosure dimensions and accessories.
Motor Load
120VAC 208-277VAC
1HP 2HP
1HP 2HP
Resistive
28VDC
30A
30A
CH 1 SPDT
SPDT
DWZ100B SERIES
TWO CHANNEL: Two programmable contacts for independent control of pool equipment and SVR or coordinated control for two speed pumps. SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart.
ORDERING INFO CATALOG NO.
DW200B DW200B-0
UPC CODE
82190 82231
TIMER SUPPLY (VAC) 60Hz
120/208-240/277VAC 120/208-240/277VAC
SPDT C
TIMER SUPPLY
NO. OF CHANNELS
2 2
DRY CONTACTS (UNPOWERED)
DWZ100B SERIES TIMER SUPPLY
N
SPDT SPDT
120
208-240 277
120V N
120
208-240 277
208-240V
120V
C
NO NC
TIMER SUPPLY
N
L N
L
277V
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
TIMER SUPPLY
LOAD N
CH 1 SPDT
DW200B SERIES
NO NC
AC LINE INPUT SELECT277V PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
DAYLIGHT SAVING: Automatic adjustment (can be omitted) for year-round pools.
DW200B SERIES
LOAD
208-240V
HOLIDAYS: 1 to 24 individual dates for preprogrammed longer run times for heavy use times.
NC
24-277VAC
WIRING DIAGRAMS
FEATURES
NO
General Purpose
TERMINAL RANGE: #12 - #16AWG.
APPLICATIONS
CONTACT RATING
VOLTAGE
120
120V N
120
C
208-240 277
208-240 277
CH 2 SPDT
C
NO NC
NO NC
C
277V L
208-240V
LOAD AC LINE INPUT N SELECT PROPER TERMINALS 277V AND APPLY ONLY ONE VOLTAGE
C
NO NC
NO NC
L
208-240V
120V
CH 2 SPDT
L LOAD L N
LOAD N
LOAD N
AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE
TWO SPEED PUMP WIRING
MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.
TWO SPEED PUMP WIRING
CLOCK FORMAT: AM/PM or Military time POWER OUTAGE BACKUP: Permanent schedule retention when timer is powered down at the end of the season. Super capacitor provides 7 days of real time backup.
POOL & SPA CONTROLS TORK 145
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
TORK 146
P1100 SERIES
QUICK INSTALL/RELEASE LEVER: For easy installation and removal when installing into pool panels.
SWIMMING POOL TIMERS, 24 HOUR ELECTROMECHANICAL CONTROL
LOAD INDICATOR LAMP
P1100 SERIES
QUICK INSTALL/RELEASE LEVER: For easy installation and removal when installing into pool panels.
SWIMMING POOL TIMERS, 7 DAY DIGITAL CONTROL
LOAD INDICATOR LAMP LARGE LCD DISPLAY
CONVENIENT EXTERNAL ROCKER SWITCH: 3 position switch: OFF/ON/AUTO. Use switch to turn OFF pump at the end of pool season.
LARGE "MANUAL" BUTTON: 3 operating modes available: OFF/ON/AUTO. Using the OFF mode, the pool can be closed down without disrupting the time settings.
REAL TIME SWITCH FACE: Easy to set and check time.
POWER OUTAGE BACKUP: Battery retains time and schedule.
CAPTIVE TRIPPERS: 15 minute intervals, no lost trippers. HEATER CONTACTS: FM suffix includes "Fireman Switch" to turn off pool heater 20-30 minutes before timer turns OFF. Contact rates SPST, 15A @120V.
7 DAY PROGRAMMING ONE MINUTE INTERVAL: Allows for the control of various electrical equipment on a 7 day schedule. 15 schedule weekly programs.
THERMOSTAT: PFP models include built in Freeze Protection. No extra wiring. Thermostat turns on load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage. ACCESSORY CONTACT: PF models include extra contact to accept PFPT Freeze Protection Accessory. Thermostat turns ON load at user settable level between 33°F adn 42°F. Moving water prevents costly freeze damage. TIMER INTERLOCK: Makes one second timer dependant on operation of another timer.
ORDERING INFO CATALOG NO.
RESISTIVE/ UPC INPUT SUPPLY CODE (VAC) 60Hz CONTACTS INDUCTIVE RATINGS
HP RATING
PFP2-M
94026
240
DPST
40A
7.5HP @ 240V
PFP3-M
94027
120/240 w/neutral
DPST
40A
3 HP @ 120V 7.5HP @ 240V
P1101-M
10056
120
DPST
40A
3 HP @ 120V
P1101FM-M
10060
120
DPST
40A
3 HP @ 120V
PF1101-M
94020
120
DPST
40A
3 HP @ 120V
PF1101FM-M
94024
120
DPST
40A
3 HP @ 120V
PFP1102-M
94022
240
DPST
40A
7.5HP @ 240V
PFP1103-M
94023
120/240 w/neutral
DPST
40A
3 HP @ 120V 7.5HP @ 240V
P1104-M
10057
240
DPST
40A
7.5HP @ 240V
P1104FM-M
10061
240
DPST
40A
7.5HP @ 240V
PF1104-M
94021
240
DPST
40A
7.5HP @ 240V
PF1104FM-M
94025
240
DPST
40A
7.5HP @ 240V
P1101-2M
10058
120
DPST
40A
2HP @ 120V
P1104-2M
10059
240
DPST
40A
5HP @ 240V
POOL & SPA CONTROLS TORK 147
NOTES
Thermostat only Thermostat only
Fireman Switch Accepts PFPT thermostat input Fireman Switch & Accepts PFPT thermostat input Freeze Protection included Freeze Protection included
Fireman Switch Accepts PFPT thermostat input Fireman Switch & Accepts PFPT thermostat input Replacement for PP-20R-2P1 Replacement for PP-20R-2P4
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
THERMOSTAT: PFPEW models include built in Freeze Protection. No extra wiring. Thermostat turns on load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage. ACCESSORY CONTACT: PFEW models include extra contact to accept PFPT Freeze Protection Accessory. Thermostat turns ON load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage.
ORDERING INFO CATALOG NO.
RESISTIVE/ UPC INPUT SUPPLY CODE (VAC) 60Hz CONTACTS INDUCTIVE RATINGS
HP RATING
PEW101-M
82432
120
DPST
40A
3 HP @ 120
PFEW101-M
94029
120
DPST
40A
PFPEW1102-M
94031
240
DPST
40A
PFPEW1103-M
94032
120/240 w/neutral
DPST
40A
Accepts PFPT thermostat input protection 7.5HP @ 240V Freeze included 3 HP @ 120V Freeze protection 7.5HP @ 240V included
PEW104-M
82442
240
DPST
40A
7.5HP @ 240V
PFEW104-M
94030
240
DPST
40A
Accepts PFPT 7.5HP @ 240V thermostat input
NOTES
TIMER INTERLOCK: Makes one timer dependant on operation of another timer.
3 HP @ 120
NOTE: "
" = Indicates Freeze Protection.
WIRING DIAGRAMS
POOL & SPA JUNCTION BOXES
A
B
C
APPLICATIONS For installation of underwater pool lights or low voltage connections. Solid brass with grounded post and 3 ground terminals for use with metallic or PVC conduit. NOTE: "
" = Indicates Freeze Protection.
ORDERING INFO CATALOG NO.
UPC CODE
NPF CONDUIT HUB PIPE INPUT A/B/C SIZE
PB-50
94041
1⁄2"
/ 1⁄2" / 1⁄2"
1⁄2"
PB-75
94042
3⁄4"
/ 3⁄4" / 3⁄4"
.3⁄4"
PB-100
94043
3⁄4"
/ 1"/ 3⁄4"
3⁄4"
& 1"
TORK 148
SR-500 & SR-500PS
NEW!
SAFETY VACUUM RELEASE SYSTEMS
2 1 Of all the protections you can put between your family and the risk of entrapment, the best protection is
APPLICATIONS
AT THE SOURCE.
®
A Safety Vacuum Release System (SVRS) works by monitoring the vacuum on the suction side of the pool or spa pump. When a blockage occurs in the main drain or skimmer, a sudden rise in vacuum will cause the SR-500 and SR-500PS to shut down and activate an audible alarm. The pump will remain off with the alarm sounding until manually reset.
Make Your Pool & Spa Safer, Update your
LAYERS OF PROTECTION Door alarms on doors leading to the pool or spa area help to alert parents or staff to anyone entering the pool from the house or building.
Commercial & Residential Swimming pools and spas Fountains Ponds Any pump size
WARNING ALARM: Multiple audible alarm capabilities – allows for quicker alert to harmful situations. AUXILARY CONTACTS: Accessible extra dry contact – auxiliary equipment can be added. EQUIPMENT PROTECTION: Low vacuum sensing - (prevents cavitations or running the pump dry, eliminating costly equipment failure). SCHEDULING: Programmable 24 hour timer, or as stand-alone SVRS working in conjunction with existing pool controller.
POOL & SPA CONTROLS TORK 149
Remote alarms linked to the Safety Vacuum Release System (SVRS) alert parents or attendants when the SVRS is activated, indicating that someone in the pool may need help.
ORDERING INFO
FEATURES PROTECTION: • Provides an important layer of protection, reducing entrapment risk. • Turns off pump in milliseconds upon detecting sudden vacuum change. • Vacuum monitored 128 times per second, rapid response and accurate readings. • Power monitored 50/60 times per second, insures continuous power detection. • Newest state-of-art NEC microprocessor technology-- guaranteed reliability and performance.
OUTSIDE THE POOL AREA Keep children from accessing the pool or spa when unattended
DOOR ALARMS
1
POWER OUTAGE BACKUP: Insures settings and reading will be saved, 30 minute rapid recharge.
INPUT SUPPLY DRY CONTACTS (VAC) 60Hz (UNPOWERED)
CATALOG NO.
UPC CODE
SR-500
95425
120/240
DPST
SR-500PS
95426
120/240
DPST
MAINTENANCE OVERRIDE: 30 minute maintenance override - (for pool or spa service). BUILT-IN DIAGNOSTICS: Displays error codes, prevents guessing during troubleshooting. EASY RETROFIT: Integrates with common existing timer box Trouble free installation, no pipes to cut or glue. COMPLIANCE: ASME/ANSI 112.19.17 as required by the International Building Codes (IBC) and the International residential Codes (IRC). Meets all current codes and standards for SVRSs on new and existing pools and spas. ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R with lockable hasp. See page 153 for dimensions and additional information.
2
Restrict access to a pool or spa by surrounding the area with fencing that is equipt with a self-closing, self-latching gate closure. Utilize gate latches that are adjustable, magnetically operated as well as key lockable.
CONTACT RATINGS TYPE
General Purpose Motor
VOLTAGE
120VAC 240VAC 120VAC 240VAC
FENCE & GATE
3
An emergency STOP button allows parents or attendants in the area to immediately and easily shut down the pump system in the event of entrapment.
INSIDE THE POOL AREA Minimize the risk of entrapment injuries or drowning
CONTACT RATING
20A 3HP
EMERGENCY STOP
4
SVRS
The SVRS automatically shuts down the vacuum pump when sensing a rise in vacuum pressure – in some cases, reacting to potential entrapment conditions in LESS THAN ONE SECOND! Audible alarms linked to the SVRS alert those nearby to a potential entrapment. SVRS should meet or exceed ASME/ANSI A112.19.17 standards in order to comply with IRC and IBC codes.
5
3
DRAIN COVERS
Minimize potential entrapments or “Differential Hold Down Forces,” thereby minimizing the potential for a swimmer to be entrapped.
4
5
Anti-entrapment drain covers should meet or exceed ASME and ANSI A112.19.8 2007 and 2007 Federal Pool & Spa Safety Act and have a Certified Safe Flow Rating. Many compliant drain covers are easily retrofitted to existing drains.
ALL ITEMS AVAILABLE FROM NSi/TORK!
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
More details available in our Safety Products catalog and Layers of Protection brochure, ask your sales representative for more information.
ANTI-ENTRAPMENT DRAIN COVERS
SELF-LATCHING GATE CLOSURES & SELF-CLOSING GATE HINGES
NEW!
NEW!
640-475XV TCA1-MK2 DS360M
TCHD1ARP-MK2 AV20X20 & AV26X26
FEATURES DS360M DRAINSAFE • Designed for use with suction outlet sumps up to 8" in size, will retrofit smaller 5” sumps using additional knockouts. • Certified Safe flow of 123 GPM. • ASME/ANSI A112.19.8 2007 Standard Compliant. DS12X12P DRAINSAFE • Designed to retrofit Pentair style frames, and functions on dual drain as well as single suction outlets. • Certified Safe flow of 250 GPM @ 1.5 FPS. • ASME/ANSI A112.19.8 2007 Standard Compliant. DS12X12H DRAINSAFE • Designed to retrofit Hayward style frames, and functions on dual drain as well as single suction outlets. • Certified Safe flow of 250 GPM @ 1.5 FPS. • ASME/ANSI A112.19.8 2007 Standard Compliant.
FEATURES
DS12X12P
DS12X12H
ORDERING INFO CATALOG NO.
UPC CODE
DESCRIPTION
SURFACE AREA (SQ.IN)
RETROFIT FRAME
DS360M
95431
Drainsafe Anti-Entrapment Type Suction Outlet Cover
27
N/A
DS12X12P
95429
53
Pentair
DS12X12H
95430
53
Hayward
640-475XV
95432
159.6
18 x 18
AV20X20
95433
AV26X26
95434
Drainsafe 12 x 12" Anti-Entrapment Type Suction Outlet Cover Drainsafe 12 x 12" Anti-Entrapment Type Suction Outlet Cover Waterway 18 x 18" Anti-Entrapment Drain Cover Eureka 20 x 20" Anti-Entrapment Drain Cover Eureka 26 x 26" Anti-Entrapment Drain Cover
640-475XV WATERWAY • Designed for single and multiple drain use, the 640-475XV works on dual drain as well as single suction outlets. • Minimizes “Differential Hold Down Forces” of dual drain systems. • Certified Safe flow rate of 540 GPM @ 1.09 FPS.
73.6 108.9
12 x 12 (9 x 9 minimum) 18 x 18 (12 x 12 minimum)
MAGNA•LATCH GATE CLOSURES MagnaLatch quality latches are self-latching with permanent magnets which never lose power, for safer, child-resistant security for your swimming pool gate. The Top Pull model can be mounted so the release knob reaches the minimum code height, typically 54", on a shorter gate. It's adjustable for when the gate gets out of alignment. The Vertical Pull model is designed for gates and fences that are 60” or more in height. TRU•CLOSE GATE HINGES TruClose® hinges are designed so the residential homeowner can quickly and easily adjust tension to support a 375lbs gate load and self-closes up to a 55lb gate, for the ultimate safety around pools and other areas requiring self-closing gates. Hinges are rust-free and are self-lubricating. Regular duty and heavy duty models available.
FENCE MATERIAL
PACKAGING AVAILABLE
CATALOG NO.
UPC CODE
DESCRIPTION
MLTPS2BGA
95439
MagnaLatch Top Pull Gate Latch
MLTPRP
95445
MLVPS2BGA
95440
MLVPRP
95444
MLS2RPAKA
95446
Round Post Adapter Kit
Wholesale
MLSPACER
95447
MagnaLatch Gap Spacer
Retail
Wholesale
MagnaLatch Top Pull Gate Latch, 2" Gap
Retail
Spacer included
Wholesale
MagnaLatch Vertical Pull Gate Latch MagnaLatch Vertical Pull Gate Latch, 2"
Retail
Gap Spacer included
REGULAR DUTY MODELS TCA1RP-MK2
98018
TruClose® Regular Range Gate Hinge
Metal
Retail
TCA1-MK2
98026
TruClose® Regular Range Gate Hinge
Metal
Wholesale
TCA3RP-MK2
98019
TruClose® Regular Range Gate Hinge
Vinyl, Wood
Retail
TCA3-MK2
98027
TruClose® Regular Range Gate Hinge
Vinyl, Wood
Wholesale
TCAMA2RND
98024
TruClose® Regular Range Gate Hinge, Round frames adjustable gap
Wholesale
HEAVY DUTY MODELS
DS-MR
DS-AA
TORK 151
MLTPS2BGA
POOL & SPA SAFETY ACCESSORIES
AV20X20 & AV26X26 EUREKA • Eureka drain covers unique grating system is designed for new construction and retrofit, to add protection from entrapment. • ASME/ANSI A112.19.8 2007 Standard Compliant. • Certified Safe flow rate of 223 GPM (20x20), 495 GPM (26x26).
POOL & SPA CONTROLS
ORDERING INFO
TCHD1ARP-MK2
98020
TruClose® Heavy Duty
Metal
Retail
TCHD1AL2-MK2
98021
TruClose® Heavy Duty, with 2 legs
Metal
Wholesale
TCHD2RP-MK2
98022
TruClose® Heavy Duty
Vinyl, Wood
Retail
TCHD2L2-MK2
98023
TruClose® Heavy Duty, with 2 legs
Vinyl, Wood
Wholesale
SAFETY ACCESSORIES
SR-RA
SR-ESB
SR-RA
95437
Remote Alarm
SR-ESB
95438
Emergency Stop Button
DS-AA
95435
Drainsafe Masonry Anchor Kit - for DS360M
DS-MR
95436
Drainsafe Mud Rings, Universal Fit
ALL ITEMS AVAILABLE FROM NSi/TORK!
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com
More details available in our Safety Products catalog and Layers of Protection brochure, ask your sales representative for more information.
TORK 152
ENCLOSURES
ENCLOSURES STANDARD FOR MODELS
METAL INDOOR NEMA 1 ENCLOSURE #68229
STANDARD FOR MODELS
METAL INDOOR/OUTDOOR NEMA 3 MODEL #9006
STANDARD FOR MODELS
METAL INDOOR NEMA 1 ENCLOSURE #63016-1
MECHANISM & MOUNTING BRACKET #62153-1
MODELS
1101
7120
TZ220L-0
TZ300L-0
TZ220L
TW220L
Use Bracket #64039
1102
7122
TZ300L-0
T920L-0
TZ300L
TW300L
W100
W120 W220
3-5/8 "
W222
3-1/16"
1103
8001
W300
T920L
W200
1104
8004
W302
T930L
W202
1101FM
8061
W300L
TW222L
1104FM
8121
W302L
TW302L
7100
8301
#62158 "E" DOOR
7102
8601
T920L-E
7200
8602
TW220L-E
T930L-0
7202
TU40-Y
1101-7
EW201-Y
TRP400
7220
1847AZL LDS-A
7222
8007
7200L
8007L
7202L
8007V
7120L
8150
1847A
8150U
1848A
8007U
1849A
8007VL
1847AZ
8008
1847AL
8008L
STANDARD FOR MODELS
2-1/2"
ELC72PC/120 ELC72PC/208-240
11-1/2"
12"
W302
DLC400BP
LDSH-A
STANDARD FOR MODELS
DLC400BP
12-1/4"
T930L-E
MECHANISM ONLY
MECHANISM MECHANISM WITH BRACKET WITH BRACKET #62153-1 #64039
4"
1101NC DGLC100A-NC
1101-M-IAP
7200
1103NC DGLC200A-NC
1104-M-IAP
7202
1104NC
1102
7120
8001-NC
1103
7122
METAL INDOOR NEMA 1 ENCLOSURE #70100
DG SERIES
W200
W222L
E101PB
1103-N
W202
1847AW
E Series
W120
TU40
7-5/8"
1847AWL
DTU40
EW Series
11-7/8"
W220
DG Series DZS Series
TERMINAL BLOCK
MECHANISM ONLY GROUND 4-9/16 " SCREW
MECHANISM & BRACKET
CLEARANCE HOLE FOR GROUND SCREW
4-9/16 "
MODELS 5441
6-5/8 "
5-1/16" 4-9/16 "
7-5/8"
BRACKET
4-9/16 "
MECHANISM ONLY 4-9/16 "
3-5/8 "
TERMINAL BLOCK
MECHANISM & BRACKET
EWZ101-MB 2-3/32 "
E, EWZ, EH SERIES
EWZ103-MB
11-1/2"
BRACKET
SMC-3D
4-9/16MECHANISM " 3-5/8 " & BRACKET
6-5/8 "
EWZ201-MB
6-5/8 "
MECHANISM & BRACKET 3-3/8"
MECHANISM ONLY
EWZ120-MB 8-5/16"
3-1/16 "
2-1/2"
1-15/16 "
14-1/8"
12-3/4"
3-1/2"
TERMINAL BLOCK
MECHANISM & BRACKET DG SERIES
WIRING COMPARTMENT 10-1/8"
WITH MOUNTING BRACKET #64039
STINGL
3/4" or 1" KO
7-5/8"
6-5/8 "
3-5/8 "
1/2" or 3/4" KO
3-1/16"
Note: Indoor Enclosure Only
11-1/2"
TERMINAL BLOCK
TERMINAL BLOCK
9000PC 3-1/16"
1-15/16 "
DZS, DTS, DZM, DW, DWZ SERIES
3-1/4"
STANDARD FOR MODELS
W400A
1101D
1101DF
W402A
1114D
1114DF
W400AL
1104D
1104DF
METAL DUPLEX INDOOR/OUTDOOR NEMA 3 MODEL #9004L
4-9/16 "
4-9/16 "
6-5/8 "
EW103B-C EW120B-C
TERMINAL BLOCK
3-1/16 "
DZM, DW, DWZ BRACKET SERIES
6-5/8 "
TERMINAL BLOCK
1-15/16 "
MECHANISM & BRACKET DZS, DTS,
MECHANISM ONLY
PLASTIC INDOOR/OUTDOOR NEMA 3R WITH CLEAR WINDOW
MODELS
4-9/16 "
TERMINAL BLOCK
1-15/16 "
MECHANISM & BRACKET
8-5/16"
STANDARD FOR MODELS
SMC-3D
3-1/16 "
MECHANISM & BRACKET E, EWZ, 3-3/8"
EH
SERIES
MECHANISM ONLY
LC200M
MODELS
TERMINAL BLOCK
4-17/32 "
1102-M
1103-M
1104-M SMC-3D 8001-LC/WB
DTWH40
8601
8121
8602
8061
5-1/2"
3.4000"
EJWT E500T
MECHANISM & BRACKET 3-13/32 "
E501T
7 1/2” 7 1/ ” 2
1-13/16 "
9-3/8"
7-1/2"
PP-20RPP-20R PP-20R-P1 PP-20R-P1 PP20R-P4 PP20R-P4 PP-20R-2P1 PP-20R-2P1 PP-20R-2P4 PP-20R-2P4
MECHANISMS/BRACKETS
5-37/64 " 3-1/16 "
STANDARD FOR MODELS
STANDARD FOR MODELS 1101-O
1104-O
7302, L, Z, ZL 8001U-0
1102-0
7200-O
1103-0
7202-O
8007-0
POOL PANEL SERIES
4"
MECHANISM ONLY
METAL INDOOR/OUTDOOR NEMA 3 MODEL 9000B – SUFFIX "O"
LC200M MOUNTING WITH BRACKET
MODELS
4-11/16"
MECHANISM WITH BRACKET
LC200M
LC200M
MECHANISM & BRACKET 4-17/32 "
3-9/32 "
LDS LDSH
MECHANISM & BRACKET LC200M 3-13/32 "
LDS SERIES MOUNTING WITH BRACKET
MODELS
3.4000"
MECHANISM & BRACKET
LDS
1-13/16 "
2-1/8 "
4-17/32 "
LDSH
3-9/32 "
3.4000"
LDS LDSH
MECHANISM & BRACKET 3-13/32 "
13 3/8” 13 3/ ” 8
PP-100R PP-100R PP-100R-P4 PP-100R-P4 PP-100R-P1P4 PP-100R-P1P4 PP-100R-2P4 PP-100R-2P4 PP-100R-P4P4FM PP-100R-P4P4FM
17 3/4” 17 3/ ” 4
SHOWN WITH SNAP TRACK
3-3/8"
4 5/8” 4 5/ ” 8
4 1/4” 4 1/ ” 4
4"
7 1/2”
7300, L, Z, ZL 8001-0 8007U-0
4-11/16"
11”
3-3/4"
MECHANISM & BRACKET
8301 3-1/16"
11”
E502T
#64039/62153-1/65447
5-13/16 "
TERMINAL BLOCK
EWJT & E500T SERIES ENCLOSURE
SR-500PS
3-1/2"
4-9/16"
1-15/16 " 7000 Series 1847A, Z
1848A
3-9/32 "
STINGL SVRS ENCLOSURE
WITH MOUNTING BRACKET #62153-1
2-1/8 "
1101-M
MECHANISM & BRACKET
LDS LDSH
MECHANISM & BRACKET
MECHANISM & MOUNTING BRACKET #65446
6-5/8 "
4"
MODELS
SR-500
BRACKET
6-5/8 "
TERMINAL BLOCK
3-1/16 "
ADAPTER MECHANISM & BRACKET PLATE 4-9/16 "
MECHANISM ONLY
5-1/16"
NEMA 1 ENCLOSUREE, EWZ, EH SERIES
METAL INDOOR/OUTDOOR NEMA 3 MODEL 9000A – SUFFIX "0"
ELC712
1/2" or 3/4" KO 3/4" or 1" KO
2-3/32 "
6-5/8 "
ELC78
4-3/16"
8-3/4"
1/4" MOUNTING HOLE
W222
METAL INDOOR NEMA 1 ENCLOSURE FOR W400 SERIES
ELC78 & ELC712 ENCLOSURE
5401 ENCLOSURE
BRACKET
4-11/16"
DWZ Series
4"
12"
3-1/16 "
1-15/16 "
EWZ SERIES
MECHANISM ONLY
EWZ Series
DZM Series
STANDARD FOR MODELS
TERMINAL BLOCK
9000P
1102-N
SMC-3D
EW Series
PLASTIC INDOOR/OUTDOOR NEMA 3R #9000P
MODELS
7120Z, ZL
DW Series
E Series
7102
10"
5441 and 5440 REMOTE CONTACTORS
7202Z, ZL
DTS Series
7100
6-5/8 "
1104-N
18"
6-5/8 "
3-3/8"
W220L
BRACKET
3-5/8 "
4"
70100
W100
8001-N
4-9/16 "
12"
DWZ SERIES
1101-N
8001U-N
MECHANISM & BRACKET
2-3/32 "
ELC74 ENCLOSURE
ELC74
9/32" MOUNTING HOLES
TRP800
6-5/8 "
DZS, DTS,
7200Z, ZL
7122Z, ZL
4-9/16 "
4"
12"
TRP800
TRP 800 (GROUP OF 8)
9/32" MOUNTING HOLES
IAP BRACKET MECHANISM ONLY DG SERIES INTERMATIC ADAPTER PLATE
EWZ SeriesDZM, DW,
STANDARD FOR MODELS
10"
TRP800
NORYL® & LEXAN® INDOOR/OUTDOOR NEMA 3R MODEL #9000NC
14-1/4"
NORYL® INDOOR/OUTDOOR NEMA 3R MODEL #9000N
ELC72PC/277 18"
STANDARD FOR MODELS
DLC400BP
9/32" MOUNTING HOLES
ELC71PC/277
EW130B-Y EW120B-Y
METAL INDOOR NEMA 1 ENCLOSURE #63100
ELC71 & ELC72 SERIES ENCLOSURE
ELC71PC/120 ELC71PC/208-240
3-1/2"
TRP 400 (GROUP OF 4)
STANDARD FOR MODELS
TRP 800 (GROUP OF 8)
9/32" MOUNTING HOLES
TRP402
7-5/8"
Use Bracket #62153-1 W300
TRP400
TRP 400 (GROUP OF 4)
PP-20R PP-20R-P1 PP20R-P4 PP-20R-2P1 PP-20R-2P4
7 1/2”
PP-20R PP-20R-P1 PP20R-P4 PP-20R-2P1 PP-20R-2P4
1-13/16 "
11”
13 3/8”
13 3/8”
6 1/8” 6 1/ ” 8
12 3/4” 12 3/ ” 4
11”
PP-100R PP-100R PP-100R-P4 PP-100R-P4 PP-100R-P1P4 PP-100R-P1P4 PP-100R-2P4 PP-100R-2P4 PP-100R-P4P4FM PP-100R-P4P4FM
PP-125R PP-125R PP-125R-P4 PP-125R-P4 PP-125R-2P4 PP-125R-2P4 PP-125R-P4-100X PP-125R-P4-100X PP-125R-P4-300X PP-125R-P4-300X 17 3/ ” 17 3/ ” 4
4
PP-10R-M-GFCI PP-10R-M-GFCI PP-10R-E-GRCI PP-10R-E-GRCI
20 3/4” 20 3/ ” 4
9 3/4” 9 3/ ” 4
2-1/8 "
DZS100BP-0 DZS200BP-0 DZS200BP DW200B-0 DZM200BP-0
5-13/16 "
5-37/64 "
5-13/16 "
5-37/64 "
5401
4 1/4”
SHOWN WITH SNAP TRACK
4 5/8”
4 1/4”
4 5/8”
4 5/8” 4 5/ ” 8
4 1/2” 4 1/ ” 2
SHOWN WITH SNAP TRACK 12 3/4”
12 3/4”
PP-125R
PP-125R
6 1/8”
6 1/8”
TORK 153 PP-10R-M-GFCI PP-10R-M-GFCI
TORK 154
ALPHANUMERIC INDEX
ALPHANUMERIC INDEX
1101 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144
2104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
652A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8001U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS100BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
654A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS200BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65
1101D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
2115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
655D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS200BP-12 . . . . . . . . . . . . . . . . . . . . . . . 65
1101FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144
2116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
701A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8007L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS200BP-24 . . . . . . . . . . . . . . . . . . . . . . . 65
1101FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144
2117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
701AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8007-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS200BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2223 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
711A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8007U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D1060LA . . . . . . . . . . . . . . . . . . . . . . . . . . 104
DZS400BP . . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144
2224 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8007U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D1060M . . . . . . . . . . . . . . . . . . . . . . . . . . 104
DZS400BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65
1101-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2421 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8007V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D1060MW . . . . . . . . . . . . . . . . . . . . . . . . . 104
E101B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1101-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8007VL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D212H . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
E101PB . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1101-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7120L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D212HA . . . . . . . . . . . . . . . . . . . . . . . . . . 104
E103B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7120Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
8008L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
D212HW . . . . . . . . . . . . . . . . . . . . . . . . . . 104
E120B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7120ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
8061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
E201B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
1102-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
401A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
E500T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1102-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7122ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
8301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DG180A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
E501T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
403A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DG200A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
E502T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
405A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7200L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
90058-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
DG280A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
EJWT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
1103-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
422A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
7200-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DG280A-24 . . . . . . . . . . . . . . . . . . . . . . . . . 85
ELC712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1103-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
454D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
7200Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A502HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGLC100A-NC . . . . . . . . . . . . . . . . . . . . . . . 79
ELC71PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73
1103-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
455D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
7200ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A502HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGLC200A-NC . . . . . . . . . . . . . . . . . . . . . . . 79
ELC71PC/208-240 . . . . . . . . . . . . . . . . . . . 73
1104 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144
457Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
7202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGM100A . . . . . . . . . . . . . . . . . . . . . . . . . . 63
ELC71PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73
1104D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
460D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
7202L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A506HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGM100A-Y . . . . . . . . . . . . . . . . . . . . . . . . 63
ELC72PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73
1104DF . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
5001M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7202-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A506HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGS100A . . . . . . . . . . . . . . . . . . . . . . . . . . 85
ELC72PC/208-240 . . . . . . . . . . . . . . . . . . . 73
1104FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144
5004M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7202Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGS100A-12 . . . . . . . . . . . . . . . . . . . . . . . . 85
ELC72PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73
1104FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144
5007M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7202ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGS100A-24 . . . . . . . . . . . . . . . . . . . . . . . . 85
ELC74 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5008M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A512HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGU100A-Y . . . . . . . . . . . . . . . . . . . . . . . . . 79
ELC78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1104-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144
5021M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A512HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGUM100A . . . . . . . . . . . . . . . . . . . . . . . . . 79
ELS-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
1104-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
5024M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DGUM100A-Y . . . . . . . . . . . . . . . . . . . . . . . 79
EPC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
1104-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5026M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A515MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DIN100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EPC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
1104-O . . . . . . . . . . . . . . . . . . . . . . . . 31, 144
5231 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A515MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DIN200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EPC-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
1847A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5237 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A515MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . 81
EPC-LC . . . . . . . . . . . . . . . . . . . . . . . . . . 73, 75
1847AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
7300Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A515MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS12X12H . . . . . . . . . . . . . . . . . . . . . . . . 151
1847AW . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7300ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS12X12P . . . . . . . . . . . . . . . . . . . . . . . . . 151
EW101B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 EW103B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AWL . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A530MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS360M . . . . . . . . . . . . . . . . . . . . . . . . . . 151
EW103B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5404-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
A530MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS-AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
EW103B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1847AZL . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7302Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A530MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DS-MR . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
EW120B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
1848A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
7302ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
A530MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTS100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
EW120B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
73866 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
A560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTS200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
EW120B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
803B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
A560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTS400B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
EW201B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2000-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5500-OC . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5737TM . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
806B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
A560MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
EW201B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5737TZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
806D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
A560MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
EWZ101 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
601A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
AV20X20 . . . . . . . . . . . . . . . . . . . . . . . . . 151
DW200B . . . . . . . . . . . . . . . . . . . . . . . . . . 145
EWZ101-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2005A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
602A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8001-LC/WB . . . . . . . . . . . . . . . . . . . . . . . . 37
AV26X26 . . . . . . . . . . . . . . . . . . . . . . . . . . 151
DW200B-O . . . . . . . . . . . . . . . . . . . . . . . . 145
EWZ103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2007A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
611A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
8001-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C412H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
EWZ103-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2008A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
611D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8001-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C460M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DWZ100B . . . . . . . . . . . . . . . . . . . . . . . . . . 69
EWZ120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
621D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8001-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZM200BP . . . . . . . . . . . . . . . . . . . . . . . . . 71
EWZ120-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
2022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
631D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8001U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZM200BP-O . . . . . . . . . . . . . . . . . . . . . . . 71
EWZ201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
640-475XV . . . . . . . . . . . . . . . . . . . . . . . . 151
8001U-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
DZS100BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65
EWZ201-MB . . . . . . . . . . . . . . . . . . . . . . . . 61
TORK 155
TORK 156
ALPHANUMERIC INDEX
ALPHANUMERIC INDEX
HPS30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
PFP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
T920L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA93-2RN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TCHD1ARP-MK2 . . . . . . . . . . . . . . . . . . . . . 152
LC200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
PFP2-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147
T920L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA503SW . . . . . . . . . . . . . . . . . . . . . . . . . 138
TA94AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TCHD2L2-MK2 . . . . . . . . . . . . . . . . . . . . . . 152
LC200M . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
PFP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
T920L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA52AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA94BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TCHD2RP-MK2 . . . . . . . . . . . . . . . . . . . . . . 152
LCS115M . . . . . . . . . . . . . . . . . . . . . . . 75, 112
PFP3-M . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
T930L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA52BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA94RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TRP-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PFPEW1102 . . . . . . . . . . . . . . . . . . . . . . . 143
T930L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA52RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA-ADA . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDS-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PFPEW1102-M . . . . . . . . . . . . . . . . . . . . . . 148
T930L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TA53AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-ADB . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PFPEW1103 . . . . . . . . . . . . . . . . . . . . . . . 143
TA09 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA53AF1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-ADR . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
LDSH-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
PFPEW1103-M . . . . . . . . . . . . . . . . . . . . . . 148
TA1245Y-50 . . . . . . . . . . . . . . . . . . . . . . . 137
TA53AG . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-B1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
MLS2RPAKA . . . . . . . . . . . . . . . . . . . . . . . . 152
PFPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
TA1245Y-75 . . . . . . . . . . . . . . . . . . . . . . . 137
TA53RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-B2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP802 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
MLSPACER . . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R . . . . . . . . . . . . . . . . . . . . . . . . . . 141
TA131DAN5 . . . . . . . . . . . . . . . . . . . . . . . 136
TA54AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-B3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TRP-U . . . . . . . . . . . . . . . . . . . . . 79, 112, 116
MLTPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R-2P4 . . . . . . . . . . . . . . . . . . . . . . 141
TA131DAU . . . . . . . . . . . . . . . . . . . . . . . . 136
TA54RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TA-B-8332 . . . . . . . . . . . . . . . . . . . . . . . . . 132
TU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MLTPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R-F2F4FM . . . . . . . . . . . . . . . . . . . . 143
TA131DRN5 . . . . . . . . . . . . . . . . . . . . . . . 136
TA5508H-G1 . . . . . . . . . . . . . . . . . . . . . . . 127
TA-BBSF . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TU40-Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MLVPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141
TA131DRU1 . . . . . . . . . . . . . . . . . . . . . . . 136
TA590 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-B-KHD-1000-PP . . . . . . . . . . . . . . . . . . 131
TW-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
MLVPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152
PP-100R-P4P1 . . . . . . . . . . . . . . . . . . . . . . 141
TA152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA591 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-B-KHD-120VAC . . . . . . . . . . . . . . . . . . 131
TW-220L-E . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC10U . . . . . . . . . . . . . . . . . . . . . . . . . . 114
PP-100R-P4P4FM . . . . . . . . . . . . . . . . . . . 141
TA154 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA592 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-B-KHS-1000-PP . . . . . . . . . . . . . . . . . . 131
TW-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . 112
PP-10R-E-GFCI . . . . . . . . . . . . . . . . . . . . . . 141
TA1786B . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA598 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TAC210W . . . . . . . . . . . . . . . . . . . . . . . . . 129
TW-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . 111
PP-10R-M-GFCI . . . . . . . . . . . . . . . . . . . . . 141
TA1786CB . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA599 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TAC212WL . . . . . . . . . . . . . . . . . . . . . . . . 129
TW-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
OSC20U . . . . . . . . . . . . . . . . . . . . . . . . . . 114
PP-125-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141
TA1880 B . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TAC212WS . . . . . . . . . . . . . . . . . . . . . . . . . 129
TZ-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
PP-125R . . . . . . . . . . . . . . . . . . . . . . . . . . 141
TA1880 G . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D5B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ220L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSC5U . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
PP-125R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141
TA1882 B . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D6A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSCS20UP . . . . . . . . . . . . . . . . . . . . . . . . . 113
PP-125R-P4-100X . . . . . . . . . . . . . . . . . . . 141
TA1882 G . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D6C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9P-120 . . . . . . . . . . . . . . . . . . . . . . . 110
PP-125R-P4-300X . . . . . . . . . . . . . . . . . . . 141
TA1886 B . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA603L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D6R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ-300L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9P-277 . . . . . . . . . . . . . . . . . . . . . . . 110
PP-20R . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
TA1886 G . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA606 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-D7A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TZ-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
OSWS9PD . . . . . . . . . . . . . . . . . . . . . . . . . 110
PP-20R-2P1 . . . . . . . . . . . . . . . . . . . . . . . 141
TA1887 B . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA61 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA-D7B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
USB-MMP . . . . . . . . . . . . . . . . . . . . . . . . . . 65
OSWS9PDM . . . . . . . . . . . . . . . . . . . . . . . . 110
PP-20R-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141
TA1887 BK . . . . . . . . . . . . . . . . . . . . . . . . 132
TA62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA-D7C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147
PP-20R-F2 . . . . . . . . . . . . . . . . . . . . . . . . . 143
TA1887 G . . . . . . . . . . . . . . . . . . . . . . . . . 132
TA620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D7R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147
PP-20R-P1 . . . . . . . . . . . . . . . . . . . . . . . . 141
TA215LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA620B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D8A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147
PP-20R-P4 . . . . . . . . . . . . . . . . . . . . . . . . 141
TA236 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA620L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-D8R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147
SMC3D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
TA270A . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
TA620LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147
SR-500 . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
TA315-1N5 . . . . . . . . . . . . . . . . . . . . . . . . 130
TA631L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L10-1 . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
P1104FM-M 240VAC . . . . . . . . . . . . . . . . . 143
SR-500PS . . . . . . . . . . . . . . . . . . . . . . . . . 149
TA340-10G5 . . . . . . . . . . . . . . . . . . . . . . . 128
TA635 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L12 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
P1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147
SR-ESB . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
TA340-4G5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TA-L3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 W222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
SR-RA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
TA340-4N5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA656B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
SS13B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TA340-6G5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA666BK . . . . . . . . . . . . . . . . . . . . . . . . . . 134
TA-L6-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PB-75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
SS13F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TA340-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
TA-L8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W300-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PEW101-M . . . . . . . . . . . . . . . . . . . . . . . . 148
SS20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TA371LRN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TA740 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
TA-L9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PEW104-M . . . . . . . . . . . . . . . . . . . . . . . . 148
SS20F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
TA434-10N5 . . . . . . . . . . . . . . . . . . . . . . . 128
TA744 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
TA-M1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147
TA434-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA874-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127
TA-MTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
W400A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1101-M . . . . . . . . . . . . . . . . . . . . . . . . . 147
SS700Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 SS700ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TA44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA874-N5R . . . . . . . . . . . . . . . . . . . . . . . . 127
TA-SFPF . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W400AL . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147
SS720A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
TA45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA875-1G1 . . . . . . . . . . . . . . . . . . . . . . . . 128
TA-SFPFR . . . . . . . . . . . . . . . . . . . . . . . . . . 138
W402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PF1104-M . . . . . . . . . . . . . . . . . . . . . . . . . 147
SS720AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
TA46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA875-G1 . . . . . . . . . . . . . . . . . . . . . . . . . 127
TA-WBBF . . . . . . . . . . . . . . . . . . . . . . . . . . 138
PFEW101-M . . . . . . . . . . . . . . . . . . . . . . . 148
SS721Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TA47AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA876-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127
TCA1-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152
PFEW104-M . . . . . . . . . . . . . . . . . . . . . . . 148
SS721ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
TA47AR5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA879 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
TCA1RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1102 . . . . . . . . . . . . . . . . . . . . . . . . . . 143
SSA100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
TA47RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135
TA880-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127
TCA3-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1102-M . . . . . . . . . . . . . . . . . . . . . . . . 147
SSA100R-24 . . . . . . . . . . . . . . . . . . . . . . . 102
TA502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TA93-2AN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TCA3RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1103 . . . . . . . . . . . . . . . . . . . . . . . . . . 143
SSA200 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
TA502-BX . . . . . . . . . . . . . . . . . . . . . . . . . 138
TA93-2BN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TCAMA2RND . . . . . . . . . . . . . . . . . . . . . . . 152
PFP1103-M . . . . . . . . . . . . . . . . . . . . . . . . 147
SSA200R-24 . . . . . . . . . . . . . . . . . . . . . . . 102
TA502SW . . . . . . . . . . . . . . . . . . . . . . . . . 138
TA93-2CN5 . . . . . . . . . . . . . . . . . . . . . . . . 135
TCHD1AL2-MK2 . . . . . . . . . . . . . . . . . . . . . 152
TORK 157
TORK 158
NOTES
TERMS OF SALE
TORK VENDOR NUMBER: 662381 1. Prices are F.O.B. our plant. 2. Prices do not include any sales tax. 3. Freight charges will be prepaid on all orders $100.00 and over shipping within continental USA using standard shipping methods and service. 4. Minimum order – $100.00. 5. Claims for shortage, erroneous charges or price corrections shall be deemed waived unless made in writing, delivered to NSi within 30 days of invoice. 6. Terms of payment – 2% 10th prox. net 25th following. 7. Warranties – We strive to produce the highest quality products on the market today. NSi guarantees all products to be free of defects in material and workmanship for a period of 90 days from date of sale. Any claims for defective material must be agreed to in writing by NSi. Defective material will be replaced on an F.O.B., our factory basis. NSi disclaims the implied warranty of fitness for a particular application.
OTHER PRODUCTS AVAILABLE
ADDRESS 9730 Northcross Center Court Huntersville, North Carolina 28078 USA PHONE office 800.321.5847 technical support 888.500.4598 FAX 800.841.5566
EMAIL
[email protected]
WEB www.nsiindustries.com