Tork DT series

http://waterheatertimer.org/Tork-Digital-timers-and-manuals.html#DTU DT SERIES NEW! MORE WIRING SPACE! AUTOMATIC VOL...

0 downloads 188 Views 441KB Size
http://waterheatertimer.org/Tork-Digital-timers-and-manuals.html#DTU

DT SERIES

NEW!

MORE WIRING SPACE!

AUTOMATIC VOLTAGE DETECTION 24 HOUR OR 7 DAY HOUR TIME SWITCH NEW!

SPECIFICATIONS

CONTACT RATINGS

INPUT VOLTAGE: 120/208-240/277 VAC, 50/60 Hz (auto detection). DTWH40 is 120/240VAC (auto detection).

TYPE

Resistive

TERMINAL RANGE: #8 - #18AWG. OPERATING TEMPERATURE: -31°F to 116°F (-35°C to +47°C).

APPLICATIONS

POWER CONSUMPTION: 6VA Max.

DTU40 Pumps, motors, fans Signs and lighting Water heaters Heating and air conditioning

ENCLOSURE: DTU40 polycarbonate Indoor/ Outdoor NEMA 3R. DTWH40 polycarbonate indoor NEMA 1 enclosure with clear cover. Both with lockable hasp (see page 153 for enclosure dimensions).

DTU4 U40 DTU40

SAVE ENERGY! DTWH DT WH40 DTWH40

DTWH40 Water Heaters This timer turns OFF when rates are high and turns OFF when no one is home.

NO

NC

120-277VAC

40A

30A

Inductive

120-277VAC

30A

15A

Ballast

120VAC 277VAC

30A 20A

10A 10A

Tungsten

120VAC

15A

120VAC 240VAC 120VAC 240VAC

1HP/30FLA/90LRA 2HP/20FLA/60LRA 720VA 720VA

Resistive

28VDC

20A

Max above 104°

120-277VAC

30A

Motor Pilot duty

Avoid utility peak rates Turn off when not needed

RATING

VOLTAGE

1⁄4HP/12FLA/30LRA 1⁄2HP/12FLA/33LRA

290VA 260VA

ORDERING INFO FEATURES SCHEDULING: 7 ON & OFF pairs of set points for individual programs on each day of the week. Minimum setting is 1 minute.

CATALOG NO.

UPC CODE

TIMER SUPPLY (VAC) 60Hz

NO. OF CHANNELS

DRY CONTACTS (UNPOWERED)

DTU40

24004

120/208-240/277

1

DPDT

DTWH40

24005

120/240

1

DPDT

WIRING DIAGRAMS

DAYLIGHT SAVING: Manual button push for one hour adjustment. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

DTWH40

DTU40

Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application

EXTERNAL MANUAL OVERRIDE: DTWH40 only on clear door. Override without opening case.

TIMER SUPPLY H

N

TIMER SUPPLY NC

NO

C

NC

LOAD

RANDOM MODE: Varies ON and OFF times to create "lived-in" look when away.

L

CLOCK FORMAT: AM/PM.

Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application

N

N

NO

C

H

L

N

L

TIMER SUPPLY H

N

NC

NO

C

L

N

N

DIGITAL CONTROLS TORK 55

A DIVISION OF NSi INDUSTRIES, LLC USA &800.321.5847 &www.nsiindustries.com

L2

NO

C

LOAD L

N

L

Typical Wiring Diagram, 208-240 VAC Application TIMER SUPPLY

NC

NO

C

NC

NO

C

H

N

NC

NO

C

LOAD L1

NC

LOAD

Typical Wiring 208-240 VAC Application Typical Diagram, Wiring Diagram, 240VAC

POWER OUTAGE BACKUP: Battery retains time and schedule.

N

LOAD

L1

NC

NO

C

LOAD L2

L1

L2

L1

L2

TORK 56