HP 3499A B C Quick Reference

Trim to 5.5 x 9 inches. Agilent 3499A/B/C Switch/Control System Quick Reference Guide Front-Panel Menu Reference (SCPI ...

0 downloads 119 Views 640KB Size
Trim to 5.5 x 9 inches.

Agilent 3499A/B/C Switch/Control System Quick Reference Guide Front-Panel Menu Reference (SCPI Mode) • Turn the knob to select an item at the current menu level. • Press Enter to move to the next level in the menu. • Press the same menu key again to return to the previous menu level.

View MENU

View

ERROR á SCAN LIST á RELAY CYCLES

S.List MENU

S.List

ADD TO SCAN á CONFIG SCAN á DELAY TIME SELECT

ARM Source

SET ALL

COUNT: nnnnn

á

SET CH

nnnnn.nnn SECS

TRIG Source

Mode MENU

SELECT CH nnnnn.nnn SECS

Mode

A. Select a Slot

B. Select a DIO Port

If MUX Installed:

If DIO Installed:

CONFIG MUX

CONFIG DIO

FUNCTION

MODE

DATA POLARITY á DISP FORMAT

DECIMAL á BINARY POS POLARITY á NEG POLARITY

CONT POL POS á CONT POL NEG FLAG POL POS á FLAG POL NEG I/O POL POS á I/O POL NEG

Menu MENU

Menu

CARD PAIR á CONF EXT TRIG á INTERFACE á SELFTEST á SYST MODE á REV INFO á SERIAL NO

FIRST SLOT n

TRIG SLOT n

SECOND SLOT n

ENABLE á DISABLE

GPIB/488 á RS-232 ADDRESS

SRQ ON á SRQ OFF BAUD RATE á PARITY á FLOW

SCPI á HP 3488A

Front-Panel Menu Reference (3488 Mode) • Turn the knob to select an item at the current menu level. • Press Enter to move to the next level in the menu. • Press the same menu key again to return to the previous menu level.

View MENU

View

ERROR á SCAN LIST á RELAY CYCLES

S.List MENU

S.List

ADD TO SCAN á DELAY TIME SELECT

Mode MENU

nnnnn.nnn SECS

Mode

A. Select a Slot

B. Select a DIO Port DATA POLARITY á DISP FORMAT

CONFIG DIO

DECIMAL á BINARY

MODE CONT POL POS á CONT POL NEG

POS POLARITY á NEG POLARITY

FLAG POL POS á FLAG POL NEG I/O POL POS á I/O POL NEG

Menu MENU

Menu

CARD PAIR á CONF EXT TRIG á INTERFACE á SELFTEST á SYST MODE á REV INFO á SERIAL NO

FIRST SLOT n

TRIG SLOT n

SECOND SLOT n

ENABLE á DISABLE

GPIB/488

SCPI á HP 3488A

ADDRESS SRQ ON á SRQ OFF

Note: You can operate the 3499A/B/C in either the SCPI mode or the 3488A mode. • In the SCPI mode, you can operate the instrument from the front panel or over the remote interface (GPIB or RS-232) using SCPI commands. • In the 3488A mode, you can operate the instrument from the front panel or over the remote interface (GPIB only) using 3488A commands.

2

SCPI Commands Quick Reference • Square brackets ([ ]) indicate optional keywords or parameters. • Angle brackets (< >) enclose parameters for which you must specify a value. Default parameters are shown in bold. • A vertical bar ( | ) separates multiple parameters. Channel numbers have the form (@snn), where s is the slot number and nn is the channel number. Examples are shown below. ROUT:CLOS (@111) ROUT:CLOS (@111,112,203,204) ROUT:CLOS (@101:111)

Switch Commands [ROUTe:] CLOSe CLOSe? CLOSe:STATe? OPEN |ALL OPEN?

Specific Plug-in Commands [ROUTe:] CPAir ,|-1 CPAir? FUNCtion ,<1|2|3|4|WIRE1|WIRE2|BIWIRE2|WIRE4> FUNCtion? INPut :ATTenuation[:LEVel] , :ATTenuation[:LEVel]?

Scan List Commands [ROUTe:] SCAN[:LIST] SCAN[:LIST]? SCAN CLEar SCAN:SIZE?

Scanning Commands INITiate ABORt TRIGger[:IMMediate] *TRG

3

Scan Configuration Commands ARM :SOURce :SOURce? :COUNt |MIN|MAX|INFinity :COUNt? [MIN|MAX|INFinity] :TIMer |MIN|MAX :TIMer? [MINimum|MAXimum] TRIGger :SOURce :SOURce? :TIMer |MIN|MAX :TIMer? [MIN|MAX] [ROUTe:] [CHANnel:]DELay ,|ALL [CHANnel:]DELay? CONFigure :EXTernal[:TRIGger]:SOURce :EXTernal[:TRIGger]:SOURce? :EXTernal[:TRIGger][:OUTPut] <0|1|OFF|ON> :EXTernal[:TRIGger][:OUTPut]?

State Storage Commands *SAV

Valid Memory Locations

*RCL

01 - 10 (Rev 1.0, 2.0, 3.0) 01 - 50 (Rev 4.0)

SYSTem:STATe:DELete |ALL

Digital Input Commands SENSe:DIGital:DATA :BIT? [:][:VALue]? [:]:BLOCK? ,

Digital Output Commands SOURce:DIGital:DATA :BIT ,<0|1|POS|NEG> [:][:VALue] , [:]:BLOCK ,

4

Digital Configuration Commands SOURce:DIGital :MODE , :MODE? :CONTrol:POLarity ,<0|1|POS|NEG> :CONTrol:POLarity? :FLAG:POLarity ,<0|1|POS|NEG> :FLAG:POLarity? :IO:POLarity ,<0|1|POS|NEG> :IO:POLarity? SOURce:DIGital:DATA [:]:POLarity ,<0|1|POS|NEG> [:]:POLarity?

Digital I/O Memory Commands SOURce:DIGital:DATA [:]:TRACe , SOURce:DIGital:TRACe :DEFine ,[,] :DEFine? :DEFine:CATalog? [:DATA] , :DELete[:NAME] :DELete:ALL SENSe:DIGital:DATA [:]:TRACe , SENSe:DIGital:TRACe [:DATA]?

5

Status System Commands *CLS

STATus :OPERation:CONDition? :OPERation:ENABle :OPERation:ENABle? :OPERation[:EVENt]? :PRESet

*ESE *ESE? *SRE *SRE? *STB?

SCPI Status System

6

System Information Commands *IDN? SYSTem :CTYPE? :ERRor? :VERSion? DIAGnostic [:RELay]:CYCLes? [:RELay]:CYCLes:MAX? [:RELay]:CYCLes:CLEar

System-Level Control Commands *OPC *OPC? *RST *TST? *WAI SYSTem:CPON |ALL DIAGnostic :DISPlay[:INFOrmation] :DISPlay:STATe <0|1|OFF|ON> :DISPlay:STATe? :MONitor |||-1 :MONitor? SYSMODE <0|1|SCPI|HP3488> SYSMODE?

RS-232 Commands SYSTem :LOCal :REMote :RWLock

7

3488 Commands Quick Reference Channel numbers have the form snn, where s is the slot number and nn is the channel number. Examples are shown below. CLOSE 111 CLOSE 111,112,203,204 CLOSE 101-111

3488A Standard Commands CLOSE [,...] OPEN [,...] VIEW CTYPE CRESET [,,...] SLIST [(, or -)...] STEP CHAN [] CMON DELAY [