036-047_GCcol-rxi.qxp 11/29/2010 9:16 PM Page 44 GC COLUMNS | HIGH-PERFORMANCE RXI COLUMNS Rxi®-XLB, Rxi®-35Sil MS,...

3 downloads 63 Views 547KB Size
036-047_GCcol-rxi.qxp

11/29/2010

9:16 PM

Page 44

GC COLUMNS | HIGH-PERFORMANCE RXI COLUMNS

Rxi®-XLB, Rxi®-35Sil MS, Rxi®-17 Rxi®-XLB Columns (fused silica) (low polarity proprietary phase)

• General purpose columns exhibiting extremely low bleed. Ideal for many GC/MS applications, including pesticides, PCB congeners (e.g. Aroclor mixes), PAHs. • Unique selectivity. • Temperature range: 30 °C to 360 °C. ID 0.25mm

similar phases DB-XLB, VF-Xms

0.32mm

tech tip In combination with an Rxi®-XLB column, simple adjustments to the injection conditions can greatly improve sensitivity for active and high molecular weight Method 525.2 target compounds. By eliminating contact between the sample and the hot metal surfaces in the injection port, a Drilled Uniliner® inlet liner prevents analytes from degrading in the injection port.

O

O Si

CH3 O

Si

CH3

CH3 35%

R

Si

Y

ID 0.25mm

0.32mm

0.53mm

O

Si CH3

50%

ID 0.25mm

0.32mm

DB-17, DB-608, CP-Sil 24 CB, HP-50+ 0.53mm

ID 0.10mm 0.18mm

44

20-Meter 43702

df 0.25µm 0.50µm 1µm 0.25µm 0.50µm 1µm 0.50µm 1µm

temp. limits 50 to 340/360°C 50 to 340/360°C 50 to 320/340°C 50 to 340/360°C 50 to 340/360°C 50 to 320/340°C 50 to 320/340°C 50 to 320/340°C

15-Meter 13820 13835 13850 13821 13836 13851 13837 13852

30-Meter 13823 13838 13853 13824 13839 13854 13840 13855

NEW! More dimensions are now available!

• General purpose columns for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols. • Temperature range: 40 °C to 320 °C.

50%

similar phases

df temp. limits 10-Meter 0.10µm 30 to 340/360°C 43701 0.18µm 30 to 340/360°C

13727

(midpolarity phase; Crossbond® 50% diphenyl/50% dimethyl polysiloxane)

CH3 O

13767

13726

Rxi®-17 Columns (fused silica)

Rxi®-17 Structure

Si

13721

60-Meter

*Maximum temperatures listed are for 15- and 30-meter lengths. Longer lengths may have a slightly reduced maximum temperature.

similar phases DB-35ms, MR2, VF-35ms

13750

30-Meter 13708 13723 13738 13753 13709 13724 13739 13754 13740 13770

• Special selectivity and excellent inertness for substituted polar compounds, such as drugs, pesticides, herbicides, PCBs, phenols, etc. • Very low bleed phase for GC/MS analysis. • Extended temperature range: 50 °C to 340/360 °C.

CH3

X

15-Meter 13705 13720

(midpolarity phase; equivalent to 35% phenyl/65% dimethyl arylene polysiloxane) CH3

Si

ID 0.10mm 0.18mm

temp. limits* 30 to 340/360°C 30 to 340/360°C 30 to 340/360°C 30 to 340/360°C 30 to 340/360°C 30 to 340/360°C 30 to 340/360°C 30 to 340/360°C 30 to 340/360°C 30 to 320/340°C

Rxi®-35Sil MS Columns (fused silica)

Rxi®-35Sil MS Structure CH3

0.53mm

df 0.10µm 0.25µm 0.50µm 1.00µm 0.10µm 0.25µm 0.50µm 1.00µm 0.50µm 1.50µm

df 0.25µm 0.50µm 1.00µm 0.25µm 0.50µm 1.00µm 0.25µm 0.50µm 0.83µm 1.00µm 1.50µm

temp. limits 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C 40 to 280/320°C

15-Meter 13520 13535 13550 13521 13536 13551 13522 13537

df 0.10µm 0.18µm

temp. limits 40 to 280/320°C 40 to 280/320°C

10-Meter 13501

13552 13567

30-Meter 13523 13538 13553 13524 13539 13554 13525 13540 13569 13555 13570 20-Meter 13502

www.restek.com Website : www.chromtech.net.au E-mail : [email protected] TelNo : 03 9762 2034 . . . in AUSTRALIA